Frame | 355M/L |
---|---|
Output | 300 HP (220 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 995 rpm |
Slip | 0.50 % |
Rated voltage | 380/660 V |
Rated current | 424/244 A |
L. R. Amperes | 2756/1586 A |
LRC | 6.5 |
No load current | 177/102 A |
Rated torque | 1560 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 210 % |
Locked rotor time | 64s (cold) 36s (hot) |
Design | N |
---|---|
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3L(E) |
Rotation¹ | Both (CW and CCW) |
Noise level² | 73.0 dB(A) |
Approx. weight³ | 4326 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
95.7 | 96.1 | 96.2 |
Power factor
50% | 75% | 100% |
---|---|---|
0.68 | 0.78 | 0.82 |
Frame | 355M/L |
---|---|
Output | 300 HP (220 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 995 rpm |
Slip | 0.50 % |
Rated voltage | 400/690 V |
Rated current | 412/239 A |
L. R. Amperes | 2678/1554 A |
LRC | 6.5 |
No load current | 190/110 A |
Rated torque | 1560 ft.lb |
Locked rotor torque | 220 % |
Breakdown torque | 229 % |
Locked rotor time | 64s (cold) 36s (hot) |
Design | N |
---|---|
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3L(E) |
Rotation¹ | Both (CW and CCW) |
Noise level² | 73.0 dB(A) |
Approx. weight³ | 4326 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
95.5 | 96.1 | 96.3 |
Power factor
50% | 75% | 100% |
---|---|---|
0.64 | 0.75 | 0.80 |
Frame | 355M/L |
---|---|
Output | 300 HP (220 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 995 rpm |
Slip | 0.50 % |
Rated voltage | 415 V |
Rated current | 402 A |
L. R. Amperes | 2613 A |
LRC | 6.5 |
No load current | 201 A |
Rated torque | 1560 ft.lb |
Locked rotor torque | 240 % |
Breakdown torque | 250 % |
Locked rotor time | 64s (cold) 36s (hot) |
Design | N |
---|---|
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3L(E) |
Rotation¹ | Both (CW and CCW) |
Noise level² | 73.0 dB(A) |
Approx. weight³ | 4326 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
95.3 | 96.0 | 96.3 |
Power factor
50% | 75% | 100% |
---|---|---|
0.61 | 0.73 | 0.79 |
Frame | 355M/L |
---|---|
Output | 300 HP (220 kW) |
Number of Poles | 6 |
Frequency | 60 Hz |
Rated speed | 1195 rpm |
Slip | 0.42 % |
Rated voltage | 460 V |
Rated current | 370 A |
L. R. Amperes | 2590 A |
LRC | 7.0 |
No load current | 181 A |
Rated torque | 1300 ft.lb |
Locked rotor torque | 260 % |
Breakdown torque | 290 % |
Locked rotor time | 90s (cold) 50s (hot) |
Design | N |
---|---|
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | S1 |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | B3L(E) |
Rotation¹ | Both (CW and CCW) |
Noise level² | 77.0 dB(A) |
Approx. weight³ | 4326 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
94.8 | 95.8 | 95.8 |
Power factor
50% | 75% | 100% |
---|---|---|
0.60 | 0.72 | 0.78 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Constant Resin Flow |
Regreasing System | At Drive end and Non-drive end |
Main terminal box hole | 2xM63x1,5 |
Terminal Block | BMC - 6 pins |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 4140 Carbon Steel |
Painting | RAL 5009 203A (ISO 12944 - C2) |
Grounding Lugs | Double |
Fan Cover material | Cast Iron |
Tropicalized Painting | Without |
Fan material | Aluminum |
Bearing cap | Yes- Bearing Cap |
Balancing Method | 1/2 Key |
Drip Cover | Without |
Overload protector (phenolic) | Without overload protector |