Electric Motors
| Frame | 444/5TS |
|---|---|
| Output | 150 HP (110 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3580 rpm |
| Slip | 0.56 % |
| Rated voltage | 460 V |
| Rated current | 163 A |
| L. R. Amperes | 1288 A |
| LRC | 7.9x(Code H) |
| No load current | 53.0 A |
| Rated torque | 220 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 320 % |
| Locked rotor time | 54s (cold) 30s (hot) |
| Moment of inertia (J) | 38.5 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 81.0 dB(A) |
| Approx. weight³ | 1903 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
94.5 |
95.8 |
96.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.77 |
0.85 |
0.88 |
| Frame | 444/5TS |
|---|---|
| Output | 150 HP (110 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2975 rpm |
| Slip | 0.83 % |
| Rated voltage | 380 V |
| Rated current | 194 A |
| L. R. Amperes | 1280 A |
| LRC | 6.6x(Code G) |
| No load current | 52.0 A |
| Rated torque | 265 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 260 % |
| Locked rotor time | 37s (cold) 21s (hot) |
| Moment of inertia (J) | 38.5 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 77.0 dB(A) |
| Approx. weight³ | 1903 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.4 |
95.8 |
95.8 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.82 |
0.88 |
0.90 |
| Frame | 444/5TS |
|---|---|
| Output | 150 HP (110 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2980 rpm |
| Slip | 0.67 % |
| Rated voltage | 400 V |
| Rated current | 185 A |
| L. R. Amperes | 1332 A |
| LRC | 7.2x(Code G) |
| No load current | 56.0 A |
| Rated torque | 264 ft.lb |
| Locked rotor torque | 210 % |
| Breakdown torque | 280 % |
| Locked rotor time | 37s (cold) 21s (hot) |
| Moment of inertia (J) | 38.5 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 77.0 dB(A) |
| Approx. weight³ | 1903 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.8 |
96.2 |
96.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.80 |
0.87 |
0.89 |
| Frame | 444/5TS |
|---|---|
| Output | 150 HP (110 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2980 rpm |
| Slip | 0.67 % |
| Rated voltage | 415 V |
| Rated current | 181 A |
| L. R. Amperes | 1376 A |
| LRC | 7.6x(Code H) |
| No load current | 58.0 A |
| Rated torque | 264 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 300 % |
| Locked rotor time | 37s (cold) 21s (hot) |
| Moment of inertia (J) | 38.5 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 77.0 dB(A) |
| Approx. weight³ | 1903 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.8 |
96.2 |
96.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.78 |
0.86 |
0.88 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | 2xNPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 6002 203A (ISO 12944 - C2) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 12 |