Electric Motors
Frame | 364/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 4 |
Frequency | 60 Hz |
Rated speed | 1775 rpm |
Slip | 1.39 % |
Rated voltage | 208-230/460 V |
Rated current | 151-137/68.3 A |
L. R. Amperes | 1000-902/451 A |
LRC | 6.6x(Code G) |
No load current | 41.4-48.0/24.0 A |
Rated torque | 175 ft.lb |
Locked rotor torque | 240 % |
Breakdown torque | 260 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.25 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 67.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
94.1 | 94.5 | 95.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.75 | 0.83 | 0.87 |
Frame | 364/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1470 rpm |
Slip | 2.00 % |
Rated voltage | 380 V |
Rated current | 67.8 A |
L. R. Amperes | 427 A |
LRC | 6.3x(Code G) |
No load current | 23.8 A |
Rated torque | 176 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 240 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 63.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.7 | 93.9 | 94.2 |
Power factor
50% | 75% | 100% |
---|---|---|
0.74 | 0.84 | 0.88 |
Frame | 364/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1475 rpm |
Slip | 1.67 % |
Rated voltage | 400 V |
Rated current | 65.2 A |
L. R. Amperes | 450 A |
LRC | 6.9x(Code G) |
No load current | 25.3 A |
Rated torque | 176 ft.lb |
Locked rotor torque | 250 % |
Breakdown torque | 280 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 63.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.3 | 93.9 | 94.2 |
Power factor
50% | 75% | 100% |
---|---|---|
0.70 | 0.82 | 0.87 |
Frame | 364/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1475 rpm |
Slip | 1.67 % |
Rated voltage | 415 V |
Rated current | 64.3 A |
L. R. Amperes | 476 A |
LRC | 7.4x(Code H) |
No load current | 26.6 A |
Rated torque | 176 ft.lb |
Locked rotor torque | 280 % |
Breakdown torque | 300 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 63.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.4 | 94.2 | 94.3 |
Power factor
50% | 75% | 100% |
---|---|---|
0.68 | 0.80 | 0.86 |
Frame | 364/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1465 rpm |
Slip | 2.33 % |
Rated voltage | 380 V |
Rated current | 83.5 A |
L. R. Amperes | 434 A |
LRC | 5.2x(Code E) |
No load current | 23.8 A |
Rated torque | 212 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 200 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 63.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
94.1 | 93.6 | 93.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.80 | 0.86 | 0.88 |
Frame | 364/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1470 rpm |
Slip | 2.00 % |
Rated voltage | 400 V |
Rated current | 78.9 A |
L. R. Amperes | 458 A |
LRC | 5.8x(Code F) |
No load current | 25.3 A |
Rated torque | 211 ft.lb |
Locked rotor torque | 210 % |
Breakdown torque | 229 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 63.0 dB(A) |
Approx. weight³ | 922 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
94.1 | 93.6 | 93.6 |
Power factor
50% | 75% | 100% |
---|---|---|
0.77 | 0.84 | 0.88 |
Frame | 364/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 4 |
Frequency | 50 Hz |
Rated speed | 1470 rpm |
Slip | 2.00 % |
Rated voltage | 415 V |
Rated current | 76.5 A |
L. R. Amperes | 474 A |
LRC | 6.2x(Code G) |
No load current | 26.6 A |
Rated torque | 211 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 250 % |
Locked rotor time | 18s (cold) 10s (hot) |
Moment of inertia (J) | 22.4 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature |
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor