Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 60 Hz |
| Rated speed | 1185 rpm |
| Slip | 1.25 % |
| Rated voltage | 230/460 V |
| Rated current | 139/69.5 A |
| L. R. Amperes | 987/493 A |
| LRC | 7.1x(Code H) |
| No load current | 50.0/25.0 A |
| Rated torque | 266 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 229 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 68.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
94.1 |
94.5 |
94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.74 |
0.82 |
0.86 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 380 V |
| Rated current | 69.3 A |
| L. R. Amperes | 457 A |
| LRC | 6.6x(Code G) |
| No load current | 24.7 A |
| Rated torque | 267 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 220 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.3 |
93.4 |
93.3 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.73 |
0.83 |
0.87 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 400 V |
| Rated current | 66.5 A |
| L. R. Amperes | 485 A |
| LRC | 7.3x(Code H) |
| No load current | 26.4 A |
| Rated torque | 267 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 240 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.3 |
93.7 |
93.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.70 |
0.82 |
0.86 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 415 V |
| Rated current | 64.8 A |
| L. R. Amperes | 505 A |
| LRC | 7.8x(Code J) |
| No load current | 27.7 A |
| Rated torque | 267 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 260 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.3 |
93.7 |
93.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.67 |
0.79 |
0.85 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 980 rpm |
| Slip | 2.00 % |
| Rated voltage | 380 V |
| Rated current | 85.1 A |
| L. R. Amperes | 477 A |
| LRC | 5.6x(Code F) |
| No load current | 24.7 A |
| Rated torque | 322 ft.lb |
| Locked rotor torque | 150 % |
| Breakdown torque | 180 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.6 |
93.0 |
92.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.79 |
0.85 |
0.87 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 980 rpm |
| Slip | 2.00 % |
| Rated voltage | 400 V |
| Rated current | 80.3 A |
| L. R. Amperes | 498 A |
| LRC | 6.2x(Code G) |
| No load current | 26.4 A |
| Rated torque | 322 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 200 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.6 |
93.6 |
93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.77 |
0.84 |
0.87 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 415 V |
| Rated current | 78.3 A |
| L. R. Amperes | 525 A |
| LRC | 6.7x(Code G) |
| No load current | 27.7 A |
| Rated torque | 320 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 220 % |
| Locked rotor time | 28s (cold) 16s (hot) |
| Moment of inertia (J) | 36.9 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.6 |
93.6 |
93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.74 |
0.82 |
0.86 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | NPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | With |
| Drain | Rubber, automatic |
| Shaft Material | SAE 4140 Carbon Steel |
| Painting | RAL 5009 203A (ISO 12944 - C2) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |