Electric Motors
Frame | 404/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 6 |
Frequency | 60 Hz |
Rated speed | 1185 rpm |
Slip | 1.25 % |
Rated voltage | 230/460 V |
Rated current | 139/69.5 A |
L. R. Amperes | 987/493 A |
LRC | 7.1x(Code H) |
No load current | 50.0/25.0 A |
Rated torque | 266 ft.lb |
Locked rotor torque | 200 % |
Breakdown torque | 229 % |
Locked rotor time | 36s (cold) 20s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.25 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 68.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
94.1 | 94.5 | 94.5 |
Power factor
50% | 75% | 100% |
---|---|---|
0.74 | 0.82 | 0.86 |
Frame | 404/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 985 rpm |
Slip | 1.50 % |
Rated voltage | 380 V |
Rated current | 69.3 A |
L. R. Amperes | 457 A |
LRC | 6.6x(Code G) |
No load current | 24.7 A |
Rated torque | 267 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 220 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 64.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.3 | 93.4 | 93.3 |
Power factor
50% | 75% | 100% |
---|---|---|
0.73 | 0.83 | 0.87 |
Frame | 404/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 985 rpm |
Slip | 1.50 % |
Rated voltage | 400 V |
Rated current | 66.5 A |
L. R. Amperes | 485 A |
LRC | 7.3x(Code H) |
No load current | 26.4 A |
Rated torque | 267 ft.lb |
Locked rotor torque | 220 % |
Breakdown torque | 240 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 64.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.3 | 93.7 | 93.4 |
Power factor
50% | 75% | 100% |
---|---|---|
0.70 | 0.82 | 0.86 |
Frame | 404/5T |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 985 rpm |
Slip | 1.50 % |
Rated voltage | 415 V |
Rated current | 64.8 A |
L. R. Amperes | 505 A |
LRC | 7.8x(Code J) |
No load current | 27.7 A |
Rated torque | 267 ft.lb |
Locked rotor torque | 229 % |
Breakdown torque | 260 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 64.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.3 | 93.7 | 93.4 |
Power factor
50% | 75% | 100% |
---|---|---|
0.67 | 0.79 | 0.85 |
Frame | 404/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 980 rpm |
Slip | 2.00 % |
Rated voltage | 380 V |
Rated current | 85.1 A |
L. R. Amperes | 477 A |
LRC | 5.6x(Code F) |
No load current | 24.7 A |
Rated torque | 322 ft.lb |
Locked rotor torque | 150 % |
Breakdown torque | 180 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 64.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.6 | 93.0 | 92.4 |
Power factor
50% | 75% | 100% |
---|---|---|
0.79 | 0.85 | 0.87 |
Frame | 404/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 980 rpm |
Slip | 2.00 % |
Rated voltage | 400 V |
Rated current | 80.3 A |
L. R. Amperes | 498 A |
LRC | 6.2x(Code G) |
No load current | 26.4 A |
Rated torque | 322 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 200 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 64.0 dB(A) |
Approx. weight³ | 1036 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
93.6 | 93.6 | 93.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.77 | 0.84 | 0.87 |
Frame | 404/5T |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 985 rpm |
Slip | 1.50 % |
Rated voltage | 415 V |
Rated current | 78.3 A |
L. R. Amperes | 525 A |
LRC | 6.7x(Code G) |
No load current | 27.7 A |
Rated torque | 320 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 220 % |
Locked rotor time | 28s (cold) 16s (hot) |
Moment of inertia (J) | 36.9 sq.ft.lb |
---|---|
Design | B |
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor