05036ET3E326JM-W22 WEG 50HP JM Close Coupled Pump Electric Motor, 3600RPM

$5,893.58 USD

Shipping calculated at checkout

WEG Electric Corporation SKU: 05036ET3E326JM-W22 Barcode: 7909018548197

IC411 - TEFC, IP55, 324JM/326JM Frame, 230/460/380VAC 50/60Hz 3 Phase, 12113106, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame







Electric Motors







































Frame 324/6JM
Output 50 HP (37 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3560 rpm
Slip 1.11 %
Rated voltage 230/460 V
Rated current 112/56.1 A
L. R. Amperes 707/353 A
LRC 6.3x(Code G)
No load current 28.0/14.0 A
Rated torque 73.8 ft.lb
Locked rotor torque 240 %
Breakdown torque 229 %
Locked rotor time 36s (cold) 20s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.0 

93.0 

93.0 



Power factor















50% 75% 100%

0.81 

0.87 

0.89 









































Frame 324/6JM
Output 40 HP (30 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2960 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 55.1 A
L. R. Amperes 364 A
LRC 6.6x(Code G)
No load current 13.0 A
Rated torque 71.0 ft.lb
Locked rotor torque 240 %
Breakdown torque 229 %
Locked rotor time 39s (cold) 22s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

92.8 

92.9 

93.0 



Power factor















50% 75% 100%

0.80 

0.87 

0.89 









































Frame 324/6JM
Output 40 HP (30 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 400 V
Rated current 52.7 A
L. R. Amperes 374 A
LRC 7.1x(Code H)
No load current 14.0 A
Rated torque 70.8 ft.lb
Locked rotor torque 260 %
Breakdown torque 250 %
Locked rotor time 37s (cold) 21s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

92.2 

92.8 

93.3 



Power factor















50% 75% 100%

0.77 

0.86 

0.88 









































Frame 324/6JM
Output 40 HP (30 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2965 rpm
Slip 1.17 %
Rated voltage 415 V
Rated current 50.8 A
L. R. Amperes 366 A
LRC 7.2x(Code H)
No load current 15.0 A
Rated torque 70.8 ft.lb
Locked rotor torque 280 %
Breakdown torque 280 %
Locked rotor time 36s (cold) 20s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

92.2 

93.1 

93.3 



Power factor















50% 75% 100%

0.76 

0.85 

0.88 









































Frame 324/6JM
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2935 rpm
Slip 2.17 %
Rated voltage 380 V
Rated current 69.4 A
L. R. Amperes 361 A
LRC 5.2x(Code E)
No load current 13.0 A
Rated torque 89.5 ft.lb
Locked rotor torque 190 %
Breakdown torque 200 %
Locked rotor time 21s (cold) 12s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.0 

92.4 

91.0 



Power factor















50% 75% 100%

0.85 

0.88 

0.89 









































Frame 324/6JM
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2950 rpm
Slip 1.67 %
Rated voltage 400 V
Rated current 65.4 A
L. R. Amperes 366 A
LRC 5.6x(Code F)
No load current 14.0 A
Rated torque 89.0 ft.lb
Locked rotor torque 210 %
Breakdown torque 200 %
Locked rotor time 23s (cold) 13s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.0 

92.4 

91.7 



Power factor















50% 75% 100%

0.83 

0.88 

0.89 









































Frame 324/6JM
Output 50 HP (37 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2955 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 62.6 A
L. R. Amperes 388 A
LRC 6.2x(Code F)
No load current 15.0 A
Rated torque 88.9 ft.lb
Locked rotor torque 229 %
Breakdown torque 220 %
Locked rotor time 25s (cold) 14s (hot)




































Moment of inertia (J) 5.75 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 72.0 dB(A)
Approx. weight³ 599 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.0 

93.0 

92.4 



Power factor















50% 75% 100%

0.82 

0.87 

0.89 







Features












































Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 2" 
Terminal Block Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Pump Seal Mechanical Seal 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12 





  • Electric Motor
  • 324JM/326JM
  • TEFC
  • 3-Phase
  • 50HP
  • 3600RPM
  • Close Coupled Pump

WEG Electric Corporation