Electric Motors
| Frame | 324/6T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 60 Hz |
| Rated speed | 1775 rpm |
| Slip | 1.39 % |
| Rated voltage | 460 V |
| Rated current | 59.2 A |
| L. R. Amperes | 367 A |
| LRC | 6.2x(Code G) |
| No load current | 23.5 A |
| Rated torque | 148 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 270 % |
| Locked rotor time | 27s (cold) 15s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 66.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.0 | 94.1 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.66 | 0.77 | 0.83 |
| Frame | 324/6T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1470 rpm |
| Slip | 2.00 % |
| Rated voltage | 380 V |
| Rated current | 58.7 A |
| L. R. Amperes | 376 A |
| LRC | 6.4x(Code G) |
| No load current | 23.0 A |
| Rated torque | 143 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 260 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.5 | 93.1 | 93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.64 | 0.77 | 0.83 |
| Frame | 324/6T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1475 rpm |
| Slip | 1.67 % |
| Rated voltage | 400 V |
| Rated current | 57.1 A |
| L. R. Amperes | 400 A |
| LRC | 7.0x(Code H) |
| No load current | 24.0 A |
| Rated torque | 142 ft.lb |
| Locked rotor torque | 250 % |
| Breakdown torque | 300 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.5 | 92.8 | 93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.60 | 0.73 | 0.81 |
| Frame | 324/6T |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1478 rpm |
| Slip | 1.47 % |
| Rated voltage | 415 V |
| Rated current | 56.4 A |
| L. R. Amperes | 417 A |
| LRC | 7.4x(Code J) |
| No load current | 25.0 A |
| Rated torque | 142 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 330 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.1 | 93.0 | 93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.57 | 0.70 | 0.79 |
| Frame | 324/6T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1460 rpm |
| Slip | 2.67 % |
| Rated voltage | 380 V |
| Rated current | 71.6 A |
| L. R. Amperes | 372 A |
| LRC | 5.2x(Code E) |
| No load current | 23.0 A |
| Rated torque | 180 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 210 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.0 | 93.0 | 92.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.72 | 0.81 | 0.85 |
| Frame | 324/6T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1465 rpm |
| Slip | 2.33 % |
| Rated voltage | 400 V |
| Rated current | 68.4 A |
| L. R. Amperes | 397 A |
| LRC | 5.8x(Code F) |
| No load current | 24.0 A |
| Rated torque | 179 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 240 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 602 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 93.0 | 93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.68 | 0.79 | 0.84 |
| Frame | 324/6T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1470 rpm |
| Slip | 2.00 % |
| Rated voltage | 415 V |
| Rated current | 66.3 A |
| L. R. Amperes | 411 A |
| LRC | 6.2x(Code G) |
| No load current | 25.0 A |
| Rated torque | 179 ft.lb |
| Locked rotor torque | 210 % |
| Breakdown torque | 260 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor