Electric Motors
Frame | 324/6TC |
---|---|
Output | 30 HP (22 kW) |
Number of Poles | 6 |
Frequency | 60 Hz |
Rated speed | 1180 rpm |
Slip | 1.67 % |
Rated voltage | 230/460 V |
Rated current | 72.4/36.2 A |
L. R. Amperes | 449/224 A |
LRC | 6.2x(Code G) |
No load current | 29.0/14.5 A |
Rated torque | 134 ft.lb |
Locked rotor torque | 220 % |
Breakdown torque | 240 % |
Locked rotor time | 37s (cold) 21s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.25 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 62.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.7 | 93.0 | 93.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.65 | 0.76 | 0.82 |
Frame | 324/6TC |
---|---|
Output | 25 HP (18.5 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 975 rpm |
Slip | 2.50 % |
Rated voltage | 380 V |
Rated current | 36.9 A |
L. R. Amperes | 214 A |
LRC | 5.8x(Code G) |
No load current | 14.0 A |
Rated torque | 135 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 229 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 60.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.3 | 91.8 | 91.7 |
Power factor
50% | 75% | 100% |
---|---|---|
0.64 | 0.76 | 0.83 |
Frame | 324/6TC |
---|---|
Output | 25 HP (18.5 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 980 rpm |
Slip | 2.00 % |
Rated voltage | 400 V |
Rated current | 36.2 A |
L. R. Amperes | 228 A |
LRC | 6.3x(Code H) |
No load current | 15.0 A |
Rated torque | 134 ft.lb |
Locked rotor torque | 220 % |
Breakdown torque | 260 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 60.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.3 | 92.2 | 92.1 |
Power factor
50% | 75% | 100% |
---|---|---|
0.61 | 0.74 | 0.80 |
Frame | 324/6TC |
---|---|
Output | 25 HP (18.5 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 980 rpm |
Slip | 2.00 % |
Rated voltage | 415 V |
Rated current | 35.4 A |
L. R. Amperes | 237 A |
LRC | 6.7x(Code H) |
No load current | 16.0 A |
Rated torque | 134 ft.lb |
Locked rotor torque | 240 % |
Breakdown torque | 280 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 60.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
90.7 | 91.9 | 92.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.58 | 0.71 | 0.79 |
Frame | 324/6TC |
---|---|
Output | 30 HP (22 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 970 rpm |
Slip | 3.00 % |
Rated voltage | 380 V |
Rated current | 43.7 A |
L. R. Amperes | 214 A |
LRC | 4.9x(Code E) |
No load current | 14.0 A |
Rated torque | 162 ft.lb |
Locked rotor torque | 160 % |
Breakdown torque | 200 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 60.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.7 | 91.7 | 91.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.71 | 0.80 | 0.84 |
Frame | 324/6TC |
---|---|
Output | 30 HP (22 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 975 rpm |
Slip | 2.50 % |
Rated voltage | 400 V |
Rated current | 41.7 A |
L. R. Amperes | 225 A |
LRC | 5.4x(Code F) |
No load current | 15.0 A |
Rated torque | 162 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 220 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 60.0 dB(A) |
Approx. weight³ | 607 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.7 | 92.4 | 91.7 |
Power factor
50% | 75% | 100% |
---|---|---|
0.68 | 0.78 | 0.83 |
Frame | 324/6TC |
---|---|
Output | 30 HP (22 kW) |
Number of Poles | 6 |
Frequency | 50 Hz |
Rated speed | 980 rpm |
Slip | 2.00 % |
Rated voltage | 415 V |
Rated current | 40.7 A |
L. R. Amperes | 236 A |
LRC | 5.8x(Code G) |
No load current | 16.0 A |
Rated torque | 161 ft.lb |
Locked rotor torque | 200 % |
Breakdown torque | 240 % |
Locked rotor time | 27s (cold) 15s (hot) |
Moment of inertia (J) | 13.2 sq.ft.lb |
---|---|
Design | B |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor