Product features
| Standard | NEMA MG-1 |
|---|---|
| Frequency | 60 Hz |
| Voltage | 460//380-415 V |
| Number of poles | 2 |
| Degree of Protection | IP55 |
| Synchronous speed | 3600 rpm |
| Output rating | 30 HP |
|---|---|
| Mounting | Foot-mounted |
| Flange | Without |
| Mounting | B3L(E) |
| Terminal box¹ | Right position |
| Enclosure | IC411 - TEFC |
Electric Motors
| Frame | 180M |
|---|---|
| Output | 30 HP (22 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2950 rpm |
| Slip | 1.67 % |
| Rated voltage | 380 V |
| Rated current | 40.7 A |
| L. R. Amperes | 326 A |
| LRC | 8.0 |
| No load current | 12.2 A |
| Rated torque | 52.7 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 290 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 2.83 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 67.0 dB(A) |
| Approx. weight³ | 406 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.7 | 93.2 | 93.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.77 | 0.84 | 0.88 |
| Frame | 180M |
|---|---|
| Output | 30 HP (22 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2955 rpm |
| Slip | 1.50 % |
| Rated voltage | 400 V |
| Rated current | 39.0 A |
| L. R. Amperes | 312 A |
| LRC | 8.0 |
| No load current | 13.2 A |
| Rated torque | 52.6 ft.lb |
| Locked rotor torque | 250 % |
| Breakdown torque | 330 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 2.83 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 67.0 dB(A) |
| Approx. weight³ | 406 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.5 | 93.3 | 93.7 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.73 | 0.82 | 0.87 |
| Frame | 180M |
|---|---|
| Output | 30 HP (22 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2960 rpm |
| Slip | 1.33 % |
| Rated voltage | 415 V |
| Rated current | 37.9 A |
| L. R. Amperes | 303 A |
| LRC | 8.0 |
| No load current | 14.0 A |
| Rated torque | 52.5 ft.lb |
| Locked rotor torque | 270 % |
| Breakdown torque | 360 % |
| Locked rotor time | 19s (cold) 11s (hot) |
| Moment of inertia (J) | 2.83 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 67.0 dB(A) |
| Approx. weight³ | 406 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.3 | 93.3 | 93.8 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.70 | 0.80 | 0.86 |
| Frame | 180M |
|---|---|
| Output | 30 HP (22 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3555 rpm |
| Slip | 1.25 % |
| Rated voltage | 460 V |
| Rated current | 34.7 A |
| L. R. Amperes | 302 A |
| LRC | 8.7 |
| No load current | 12.4 A |
| Rated torque | 43.7 ft.lb |
| Locked rotor torque | 280 % |
| Breakdown torque | 409 % |
| Locked rotor time | 30s (cold) 17s (hot) |
| Moment of inertia (J) | 2.83 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 72.0 dB(A) |
| Approx. weight³ | 406 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 90.2 | 91.7 | 92.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.71 | 0.81 | 0.86 |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor