IC411 - TEFC, IP55, 213JP/215JP Frame, 230/460/380VAC 50/60Hz 3 Phase, 12757940, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame







Electric Motors







































Frame 213/5JP
Output 3 HP (2.2 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1175 rpm
Slip 2.08 %
Rated voltage 230/460 V
Rated current 8.83/4.41 A
L. R. Amperes 61.8/30.9 A
LRC 7.0x(Code K)
No load current 5.50/2.75 A
Rated torque 13.4 ft.lb
Locked rotor torque 200 %
Breakdown torque 280 %
Locked rotor time 104s (cold) 58s (hot)




































Moment of inertia (J) 1.20 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 55.0 dB(A)
Approx. weight³ 165 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

86.5 

88.5 

89.5 



Power factor















50% 75% 100%

0.50 

0.63 

0.70 









































Frame 213/5JP
Output 3 HP (2.2 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 965 rpm
Slip 3.50 %
Rated voltage 380 V
Rated current 5.09 A
L. R. Amperes 29.5 A
LRC 5.8x(Code H)
No load current 2.72 A
Rated torque 16.3 ft.lb
Locked rotor torque 170 %
Breakdown torque 210 %
Locked rotor time 72s (cold) 40s (hot)




































Moment of inertia (J) 1.20 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 165 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

87.5 

88.5 

87.5 



Power factor















50% 75% 100%

0.57 

0.70 

0.75 









































Frame 213/5JP
Output 3 HP (2.2 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 400 V
Rated current 4.92 A
L. R. Amperes 31.5 A
LRC 6.4x(Code J)
No load current 2.91 A
Rated torque 16.2 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 72s (cold) 40s (hot)




































Moment of inertia (J) 1.20 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 165 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

86.5 

88.5 

88.5 



Power factor















50% 75% 100%

0.53 

0.66 

0.73 









































Frame 213/5JP
Output 3 HP (2.2 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 970 rpm
Slip 3.00 %
Rated voltage 415 V
Rated current 4.87 A
L. R. Amperes 33.1 A
LRC 6.8x(Code J)
No load current 3.05 A
Rated torque 16.2 ft.lb
Locked rotor torque 220 %
Breakdown torque 270 %
Locked rotor time 72s (cold) 40s (hot)




































Moment of inertia (J) 1.20 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 53.0 dB(A)
Approx. weight³ 165 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

86.5 

88.5 

88.5 



Power factor















50% 75% 100%

0.50 

0.64 

0.71 







Features










































Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Main terminal box hole NPT 1" 
Terminal Block Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 5009 207A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Steel 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Pump Seal Gasket 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity





  • Electric Motor
  • 213JP
  • 215JP
  • TEFC
  • 3-Phase
  • 3HP
  • 1200RPM
  • Close Coupled Pump

WEG Electric Corporation