65018ET3G588/9-W22 WEG 650HP Severe Duty Electric Motor, 1800RPM

$59,363.89 USD

Shipping calculated at checkout

WEG Electric Corporation SKU: 65018ET3G588/9-W22 Barcode: 7909265621575

IC411 - TEFC, IP55, 588T/589T Frame, 460VAC 60Hz 3 Phase, 13205890, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-7/8" Keyed Shaft







Electric Motors







































Frame 588/9T
Output 650 HP (480 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1790 rpm
Slip 0.56 %
Rated voltage 460 V
Rated current 734 A
L. R. Amperes 5432 A
LRC 7.4x(Code H)
No load current 235 A
Rated torque 1910 ft.lb
Locked rotor torque 250 %
Breakdown torque 270 %
Locked rotor time 39s (cold) 22s (hot)



































Moment of inertia (J) 301 sq.ft.lb
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 81.0 dB(A)
Approx. weight³ 5215 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

96.0 

96.5 

96.6 



Power factor















50% 75% 100%

0.71 

0.81 

0.85 









































Frame 588/9T
Output 550 HP (400 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 380 V
Rated current 741 A
L. R. Amperes 5187 A
LRC 7.0x(Code G)
No load current 230 A
Rated torque 1940 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 36s (cold) 20s (hot)



































Moment of inertia (J) 301 sq.ft.lb
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 5215 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

96.2 

96.5 

96.5 



Power factor















50% 75% 100%

0.72 

0.81 

0.85 









































Frame 588/9T
Output 550 HP (400 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 400 V
Rated current 712 A
L. R. Amperes 5554 A
LRC 7.8x(Code H)
No load current 257 A
Rated torque 1940 ft.lb
Locked rotor torque 260 %
Breakdown torque 290 %
Locked rotor time 36s (cold) 20s (hot)



































Moment of inertia (J) 301 sq.ft.lb
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 5215 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

95.8 

96.2 

96.5 



Power factor















50% 75% 100%

0.68 

0.78 

0.84 









































Frame 588/9T
Output 550 HP (400 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1490 rpm
Slip 0.67 %
Rated voltage 415 V
Rated current 703 A
L. R. Amperes 5905 A
LRC 8.4x(Code J)
No load current 280 A
Rated torque 1940 ft.lb
Locked rotor torque 280 %
Breakdown torque 320 %
Locked rotor time 36s (cold) 20s (hot)



































Moment of inertia (J) 301 sq.ft.lb
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 76.0 dB(A)
Approx. weight³ 5215 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

95.8 

96.2 

96.5 



Power factor















50% 75% 100%

0.64 

0.76 

0.82 







Features












































Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System Extended, at Drive end and Non-drive end 
Space Heater Voltage 200 - 240 V 
Main terminal box hole 2xNPT 4" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C2) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12 





  • 460VAC
  • Electric Motor
  • 588T
  • 589T
  • TEFC
  • 3-Phase
  • 650HP
  • 1800RPM
  • Severe Duty

WEG Electric Corporation