Electric Motors
| Frame | 445/7TS |
|---|---|
| Output | 250 HP (185 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3575 rpm |
| Slip | 0.69 % |
| Rated voltage | 460 V |
| Rated current | 267 A |
| L. R. Amperes | 2109 A |
| LRC | 7.9x(Code H) |
| No load current | 70.0 A |
| Rated torque | 367 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 300 % |
| Locked rotor time | 41s (cold) 23s (hot) |
| Moment of inertia (J) | 46.7 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 81.0 dB(A) |
| Approx. weight³ | 2303 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.8 |
96.5 |
96.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.82 |
0.88 |
0.90 |
| Frame | 445/7TS |
|---|---|
| Output | 250 HP (185 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2970 rpm |
| Slip | 1.00 % |
| Rated voltage | 380 V |
| Rated current | 321 A |
| L. R. Amperes | 2215 A |
| LRC | 6.9x(Code G) |
| No load current | 68.0 A |
| Rated torque | 442 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 240 % |
| Locked rotor time | 23s (cold) 13s (hot) |
| Moment of inertia (J) | 46.7 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 81.0 dB(A) |
| Approx. weight³ | 2303 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.8 |
96.2 |
96.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.87 |
0.90 |
0.91 |
| Frame | 445/7TS |
|---|---|
| Output | 250 HP (185 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2975 rpm |
| Slip | 0.83 % |
| Rated voltage | 400 V |
| Rated current | 308 A |
| L. R. Amperes | 2310 A |
| LRC | 7.5x(Code H) |
| No load current | 72.0 A |
| Rated torque | 441 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 270 % |
| Locked rotor time | 23s (cold) 13s (hot) |
| Moment of inertia (J) | 46.7 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 81.0 dB(A) |
| Approx. weight³ | 2303 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
95.8 |
96.2 |
96.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.85 |
0.89 |
0.90 |
| Frame | 445/7TS |
|---|---|
| Output | 250 HP (185 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2975 rpm |
| Slip | 0.83 % |
| Rated voltage | 415 V |
| Rated current | 300 A |
| L. R. Amperes | 2400 A |
| LRC | 8.0x(Code H) |
| No load current | 76.0 A |
| Rated torque | 441 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 300 % |
| Locked rotor time | 23s (cold) 13s (hot) |
| Moment of inertia (J) | 46.7 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 81.0 dB(A) |
| Approx. weight³ | 2303 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
96.2 |
96.5 |
96.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.83 |
0.88 |
0.89 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | 2xNPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 6002 203A (ISO 12944 - C2) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 12 |