WEG Electric Corporation SKU: 20012ET3G449T-W22 Barcode: 7894171991242

IC411 - TEFC, IP55, 447T/449T Frame, 460VAC 60Hz 3 Phase, 11380921, NEMA Premium Efficiency, Foot Mounted, Cast Iron Frame, 3-3/8" Keyed Shaft







Electric Motors







































Frame 447/9T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1187 rpm
Slip 1.08 %
Rated voltage 460 V
Rated current 237 A
L. R. Amperes 1564 A
LRC 6.6x(Code G)
No load current 90.0 A
Rated torque 885 ft.lb
Locked rotor torque 229 %
Breakdown torque 240 %
Locked rotor time 43s (cold) 24s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

95.0 

95.4 

95.8 



Power factor















50% 75% 100%

0.68 

0.79 

0.83 









































Frame 447/9T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 988 rpm
Slip 1.20 %
Rated voltage 380 V
Rated current 214 A
L. R. Amperes 1391 A
LRC 6.5x(Code G)
No load current 85.0 A
Rated torque 797 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 91s (cold) 51s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

95.1 

95.1 



Power factor















50% 75% 100%

0.65 

0.76 

0.82 









































Frame 447/9T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 209 A
L. R. Amperes 1505 A
LRC 7.2x(Code H)
No load current 90.0 A
Rated torque 796 ft.lb
Locked rotor torque 250 %
Breakdown torque 280 %
Locked rotor time 50s (cold) 28s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

95.1 

95.1 



Power factor















50% 75% 100%

0.62 

0.74 

0.80 









































Frame 447/9T
Output 150 HP (110 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 990 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 204 A
L. R. Amperes 1632 A
LRC 8.0x(Code J)
No load current 95.0 A
Rated torque 796 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 46s (cold) 26s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

95.1 

95.1 



Power factor















50% 75% 100%

0.59 

0.71 

0.79 









































Frame 447/9T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 380 V
Rated current 285 A
L. R. Amperes 1482 A
LRC 5.2x(Code E)
No load current 85.0 A
Rated torque 1070 ft.lb
Locked rotor torque 180 %
Breakdown torque 190 %
Locked rotor time 23s (cold) 13s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

94.5 

94.0 



Power factor















50% 75% 100%

0.74 

0.83 

0.85 









































Frame 447/9T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 983 rpm
Slip 1.70 %
Rated voltage 400 V
Rated current 273 A
L. R. Amperes 1638 A
LRC 6.0x(Code G)
No load current 92.0 A
Rated torque 1070 ft.lb
Locked rotor torque 200 %
Breakdown torque 210 %
Locked rotor time 25s (cold) 14s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

94.5 

94.5 



Power factor















50% 75% 100%

0.71 

0.81 

0.84 









































Frame 447/9T
Output 200 HP (150 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 985 rpm
Slip 1.50 %
Rated voltage 415 V
Rated current 265 A
L. R. Amperes 1749 A
LRC 6.6x(Code G)
No load current 95.0 A
Rated torque 1070 ft.lb
Locked rotor torque 220 %
Breakdown torque 229 %
Locked rotor time 27s (cold) 15s (hot)




































Moment of inertia (J) 145 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 105 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 2781 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.0 

94.5 

95.0 



Power factor















50% 75% 100%

0.68 

0.79 

0.83 







Features




















































Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole 2xNPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 203A (ISO 12944 - C3) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  
Connection Cables Quantity 12 
Fan material Aluminum 
Screw cap CARBON STEEL SAE 1010/20 
NDE bearing Seal WSeal 
DE bearing Seal WSeal 
Cable Press Material Sem 





  • 460VAC
  • Electric Motor
  • 447T/449T
  • TEFC
  • 3-Phase
  • 200HP
  • 1200RPM
  • Severe Duty

WEG Electric Corporation