Electric Motors
Frame | 364/5TS |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 2 |
Frequency | 60 Hz |
Rated speed | 3550 rpm |
Slip | 1.39 % |
Rated voltage | 460 V |
Rated current | 67.0 A |
L. R. Amperes | 429 A |
LRC | 6.4x(Code G) |
No load current | 15.0 A |
Rated torque | 88.8 ft.lb |
Locked rotor torque | 190 % |
Breakdown torque | 250 % |
Locked rotor time | 25s (cold) 14s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.25 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 79.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.7 | 93.0 | 93.6 |
Power factor
50% | 75% | 100% |
---|---|---|
0.81 | 0.88 | 0.90 |
Frame | 364/5TS |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2945 rpm |
Slip | 1.83 % |
Rated voltage | 380 V |
Rated current | 66.6 A |
L. R. Amperes | 406 A |
LRC | 6.1x(Code F) |
No load current | 15.0 A |
Rated torque | 89.2 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 240 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 74.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
92.1 | 92.8 | 92.8 |
Power factor
50% | 75% | 100% |
---|---|---|
0.81 | 0.88 | 0.91 |
Frame | 364/5TS |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2950 rpm |
Slip | 1.67 % |
Rated voltage | 400 V |
Rated current | 63.7 A |
L. R. Amperes | 433 A |
LRC | 6.8x(Code G) |
No load current | 16.2 A |
Rated torque | 89.0 ft.lb |
Locked rotor torque | 210 % |
Breakdown torque | 270 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 74.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.7 | 92.8 | 93.1 |
Power factor
50% | 75% | 100% |
---|---|---|
0.79 | 0.87 | 0.90 |
Frame | 364/5TS |
---|---|
Output | 50 HP (37 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2955 rpm |
Slip | 1.50 % |
Rated voltage | 415 V |
Rated current | 62.1 A |
L. R. Amperes | 447 A |
LRC | 7.2x(Code H) |
No load current | 17.4 A |
Rated torque | 88.9 ft.lb |
Locked rotor torque | 220 % |
Breakdown torque | 290 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 74.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
91.6 | 92.9 | 93.1 |
Power factor
50% | 75% | 100% |
---|---|---|
0.76 | 0.85 | 0.89 |
Frame | 364/5TS |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2935 rpm |
Slip | 2.17 % |
Rated voltage | 380 V |
Rated current | 81.3 A |
L. R. Amperes | 407 A |
LRC | 5.0x(Code D) |
No load current | 15.0 A |
Rated torque | 107 ft.lb |
Locked rotor torque | 150 % |
Breakdown torque | 200 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 74.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
92.4 | 93.0 | 92.4 |
Power factor
50% | 75% | 100% |
---|---|---|
0.85 | 0.90 | 0.91 |
Frame | 364/5TS |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2940 rpm |
Slip | 2.00 % |
Rated voltage | 400 V |
Rated current | 77.6 A |
L. R. Amperes | 435 A |
LRC | 5.6x(Code F) |
No load current | 16.2 A |
Rated torque | 107 ft.lb |
Locked rotor torque | 170 % |
Breakdown torque | 220 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Service factor | 1.00 |
Temperature rise | 105 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 74.0 dB(A) |
Approx. weight³ | 864 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
92.4 | 93.0 | 93.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.83 | 0.89 | 0.90 |
Frame | 364/5TS |
---|---|
Output | 60 HP (45 kW) |
Number of Poles | 2 |
Frequency | 50 Hz |
Rated speed | 2945 rpm |
Slip | 1.83 % |
Rated voltage | 415 V |
Rated current | 74.8 A |
L. R. Amperes | 449 A |
LRC | 6.0x(Code F) |
No load current | 17.4 A |
Rated torque | 107 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 240 % |
Locked rotor time | 21s (cold) 12s (hot) |
Moment of inertia (J) | 10.6 sq.ft.lb |
---|---|
Design | B |
Insulation Class | F |
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor
$19.99 | $24.99
Product title
Vendor