Electric Motors
| Frame | 324/6TS |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3570 rpm |
| Slip | 0.83 % |
| Rated voltage | 230/460 V |
| Rated current | 114/57.1 A |
| L. R. Amperes | 948/474 A |
| LRC | 8.3x(Code J) |
| No load current | 39.0/19.5 A |
| Rated torque | 73.5 ft.lb |
| Locked rotor torque | 330 % |
| Breakdown torque | 330 % |
| Locked rotor time | 45s (cold) 25s (hot) |
| Moment of inertia (J) | 5.43 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 76.0 dB(A) |
| Approx. weight³ | 600 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.0 | 94.5 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.74 | 0.83 | 0.86 |
| Frame | 324/6TS |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2960 rpm |
| Slip | 1.33 % |
| Rated voltage | 380 V |
| Rated current | 67.9 A |
| L. R. Amperes | 448 A |
| LRC | 6.6x(Code G) |
| No load current | 18.0 A |
| Rated torque | 88.7 ft.lb |
| Locked rotor torque | 250 % |
| Breakdown torque | 260 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 5.43 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 72.0 dB(A) |
| Approx. weight³ | 600 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.6 | 94.1 | 94.1 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.80 | 0.86 | 0.88 |
| Frame | 324/6TS |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2965 rpm |
| Slip | 1.17 % |
| Rated voltage | 400 V |
| Rated current | 65.0 A |
| L. R. Amperes | 468 A |
| LRC | 7.2x(Code H) |
| No load current | 20.0 A |
| Rated torque | 88.6 ft.lb |
| Locked rotor torque | 270 % |
| Breakdown torque | 290 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 5.43 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 72.0 dB(A) |
| Approx. weight³ | 600 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 94.5 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.76 | 0.84 | 0.87 |
| Frame | 324/6TS |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2965 rpm |
| Slip | 1.17 % |
| Rated voltage | 415 V |
| Rated current | 63.3 A |
| L. R. Amperes | 506 A |
| LRC | 8.0x(Code J) |
| No load current | 21.2 A |
| Rated torque | 88.6 ft.lb |
| Locked rotor torque | 290 % |
| Breakdown torque | 320 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 5.43 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 72.0 dB(A) |
| Approx. weight³ | 600 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.6 | 94.5 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.73 | 0.82 | 0.86 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | NPT 2" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 6002 203A (ISO 12944 - C2) |
| Grounding Lugs | Single |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
| Connection Cables Quantity | 12 |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor