02012EG3E286T-W22 WEG 20HP Electric Motor, 1200RPM

$3,878.62 USD

Shipping calculated at checkout

WEG Electric Corporation SKU: 02012EG3E286T-W22 Barcode: 7891327885134

IC411 - TEFC, IP55, 284T/286T Frame, 208-230/460VAC 60Hz 3 Phase, 11792073, Super Premium Efficiency, Foot Mounted, Cast Iron Frame, 1-7/8" Keyed Shaft






Electric Motors







































Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 60 Hz
Rated speed 1180 rpm
Slip 1.67 %
Rated voltage 230/460 V
Rated current 48.8/24.4 A
L. R. Amperes 361/181 A
LRC 7.4x(Code J)
No load current 24.0/12.0 A
Rated torque 89.0 ft.lb
Locked rotor torque 270 %
Breakdown torque 300 %
Locked rotor time 36s (cold) 20s (hot)




































Moment of inertia (J) 9.29 sq.ft.lb
Design A
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 59.0 dB(A)
Approx. weight³ 439 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

91.7 

92.4 

93.0 



Power factor















50% 75% 100%

0.67 

0.78 

0.83 









































Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 975 rpm
Slip 2.50 %
Rated voltage 380 V
Rated current 29.1 A
L. R. Amperes 175 A
LRC 6.0x(Code G)
No load current 12.0 A
Rated torque 108 ft.lb
Locked rotor torque 200 %
Breakdown torque 240 %
Locked rotor time 32s (cold) 18s (hot)




































Moment of inertia (J) 9.29 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 439 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

90.5 

91.0 

91.2 



Power factor















50% 75% 100%

0.71 

0.81 

0.86 









































Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 400 V
Rated current 28.1 A
L. R. Amperes 183 A
LRC 6.5x(Code H)
No load current 13.0 A
Rated torque 107 ft.lb
Locked rotor torque 229 %
Breakdown torque 260 %
Locked rotor time 32s (cold) 18s (hot)




































Moment of inertia (J) 9.29 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 439 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

90.5 

91.2 

91.7 



Power factor















50% 75% 100%

0.68 

0.79 

0.84 









































Frame 284/6T
Output 20 HP (15 kW)
Number of Poles 6
Frequency 50 Hz
Rated speed 980 rpm
Slip 2.00 %
Rated voltage 415 V
Rated current 27.3 A
L. R. Amperes 188 A
LRC 6.9x(Code H)
No load current 13.5 A
Rated torque 107 ft.lb
Locked rotor torque 250 %
Breakdown torque 290 %
Locked rotor time 32s (cold) 18s (hot)




































Moment of inertia (J) 9.29 sq.ft.lb
Design A
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 56.0 dB(A)
Approx. weight³ 439 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

90.5 

91.5 

92.0 



Power factor















50% 75% 100%

0.65 

0.77 

0.83 







Features










































Frame Material Cast Iron 
Impregnation Method Dip and Bake Polyester 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 1 1/2" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Rubber, automatic 
Shaft Material SAE 1040/45 Carbon Steel 
Painting RAL 6002 203A (ISO 12944 - C2) 
Grounding Lugs Single 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Plastic 
Bearing cap Yes- Bearing Cap 
Balancing Method 1/2 Key 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  





  • 208VAC
  • 230VAC
  • 460VAC
  • Electric Motor
  • 284T/286T
  • TEFC
  • 3-Phase
  • 20HP
  • 1200RPM

WEG Electric Corporation