Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 60 Hz |
| Rated speed | 1188 rpm |
| Slip | 1.00 % |
| Rated voltage | 230/460 V |
| Rated current | 144/72.2 A |
| L. R. Amperes | 1242/621 A |
| LRC | 8.6x(Code K) |
| No load current | 68.0/34.0 A |
| Rated torque | 265 ft.lb |
| Locked rotor torque | 280 % |
| Breakdown torque | 320 % |
| Locked rotor time | 39s (cold) 22s (hot) |
| Moment of inertia (J) | 39.1 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 68.0 dB(A) |
| Approx. weight³ | 1213 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 95.0 | 95.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.65 | 0.77 | 0.82 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 380 V |
| Rated current | 85.5 A |
| L. R. Amperes | 599 A |
| LRC | 7.0x(Code H) |
| No load current | 33.0 A |
| Rated torque | 320 ft.lb |
| Locked rotor torque | 210 % |
| Breakdown torque | 260 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 39.1 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1213 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.6 | 94.1 | 94.1 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.71 | 0.81 | 0.85 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 985 rpm |
| Slip | 1.50 % |
| Rated voltage | 400 V |
| Rated current | 81.8 A |
| L. R. Amperes | 638 A |
| LRC | 7.8x(Code J) |
| No load current | 36.0 A |
| Rated torque | 320 ft.lb |
| Locked rotor torque | 240 % |
| Breakdown torque | 290 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 39.1 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1213 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 94.5 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.68 | 0.79 | 0.84 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 6 |
| Frequency | 50 Hz |
| Rated speed | 987 rpm |
| Slip | 1.30 % |
| Rated voltage | 415 V |
| Rated current | 80.8 A |
| L. R. Amperes | 687 A |
| LRC | 8.5x(Code K) |
| No load current | 38.0 A |
| Rated torque | 319 ft.lb |
| Locked rotor torque | 270 % |
| Breakdown torque | 320 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 39.1 sq.ft.lb |
|---|---|
| Design | A |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 64.0 dB(A) |
| Approx. weight³ | 1213 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 94.5 | 94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.65 | 0.76 | 0.82 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Constant Resin Flow |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | NPT 3" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 4140 Carbon Steel |
| Painting | RAL 6002 203A (ISO 12944 - C2) |
| Grounding Lugs | Double |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Balancing Method | 1/2 Key |
| Drip Cover | Without |
| Overload protector (phenolic) | Without overload protector |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor