LC1D806LE7 Schneider Electric Contactor, 3 Pole media thumbnails
USO3MGO91US1ANB0
OIHD6KUA1US1ANB0
QIHD6KUA1US1ANB0
SIHD6KUA1US1ANB0
UIHD6KUA1US1ANB0
0JHD6KUA1US1ANB0

LC1D806LE7 Schneider Electric Contactor, 3 Pole

$299.97 USD

Shipping calculated at checkout

Schneider Electric (Square D) SKU: LC1D806LE7 Barcode: 3389118058811

New, Surplus Stock. 208VAC 50/60Hz Coil

3 In Stock!



















































































































Main
range

TeSys


product name

TeSys D


product or component type

Contactor


device short name

LC1D


contactor application

Motor control
Resistive load


utilisation category

AC-3
AC-1


poles description

3P


power pole contact composition

3 NO


[Ue] rated operational voltage

Power circuit <= 300 V DC 25...400 Hz
Power circuit <= 690 V AC


[Ie] rated operational current

125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
80 A (at <60 °C) at <= 440 V AC AC-3 for power circuit


motor power kW

22 kW 220...230 V AC 50/60 Hz
37 kW 380...400 V AC 50/60 Hz
45 kW 415...440 V AC 50/60 Hz
55 kW 500 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
45 kW 1000 V AC 50/60 Hz


motor power HP (UL / CSA)

20 hp 200/208 V AC 50/60 Hz 3 phase
7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors


control circuit type

AC at 50/60 Hz


[Uc] control circuit voltage

208 V AC 50/60 Hz


auxiliary contact composition

1 NO + 1 NC


[Uimp] rated impulse withstand voltage

8 kV conforming to IEC 60947


overvoltage category

III


[Ith] conventional free air thermal current

10 A 140 °F (60 °C) signalling circuit
125 A (at 60 °C) for power circuit


Irms rated making capacity

140 A AC signalling circuit IEC 60947-5-1
250 A DC signalling circuit IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947


rated breaking capacity

1100 A at 440 V for power circuit conforming to IEC 60947


[Icw] rated short-time withstand current

640 A 40 °C - 10 s for power circuit
990 A 40 °C - 1 s for power circuit
135 A 40 °C - 10 min for power circuit
320 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit


associated fuse rating

10 A gG signalling circuit IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit


average impedance

0.8 mOhm - Ith 125 A 50 Hz for power circuit


[Ui] rated insulation voltage

Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL


electrical durability

0.8 Mcycles 125 A AC-1 at Ue <= 440 V
1.5 Mcycles 80 A AC-3 at Ue <= 440 V


power dissipation per pole

5.1 W AC-3
12.5 W AC-1


Front cover

With


mounting support

Rail
Plate


standards

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508


product certifications

GOST
DNV
UL
CCC
LROS (Lloyds register of shipping)
BV
CSA
GL
RINA


connections - terminals

Control circuit: lugs-ring terminals (external diameter: 8 mm)
Power circuit bars 1 3 x 16 mm
Power circuit lugs-ring terminals 0.67 in (17 mm))


tightening torque

Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5
Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals flat Ø 8 mm M6
Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6
Power circuit 106.21 lbf.in (12 N.m) bars flat Ø 8 mm M6
Power circuit 106.21 lbf.in (12 N.m) bars hexagonal 0.39 in (10 mm) M6


operating time

20...35 ms closing
6...20 ms opening


safety reliability level

B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1


mechanical durability

4 Mcycles


maximum operating rate

3600 cyc/h 140 °F (60 °C)














































Complementary
coil technology

Without built-in suppressor module


control circuit voltage limits

0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz
0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz
1...1.1 Uc (55…70 °C):operational AC 50/60 Hz


inrush power in VA

245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C)


hold-in power consumption in VA

26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)


heat dissipation

6…10 W at 50/60 Hz


auxiliary contacts type

type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1


signalling circuit frequency

25...400 Hz


minimum switching current

5 mA signalling circuit


minimum switching voltage

17 V signalling circuit


non-overlap time

1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact


insulation resistance

> 10 MOhm signalling circuit


contact compatibility

M11


compatibility code

LC1D














































Environment
IP degree of protection

IP20 front face IEC 60529


protective treatment

TH IEC 60068-2-30


pollution degree

3


ambient air temperature for operation

-40…60 °C
60…70 °C with derating


ambient air temperature for storage

-76…176 °F (-60…80 °C)


operating altitude

0...3000 m


fire resistance

1562 °F (850 °C) IEC 60695-2-1


flame retardance

V1 UL 94


mechanical robustness

Vibrations contactor open: 2 Gn, 5...300 Hz
Shocks contactor open: 8 Gn for 11 ms
Vibrations contactor closed: 3 Gn, 5...300 Hz
Shocks contactor closed: 10 Gn for 11 ms


height

5.00 in (127 mm)


Maximum Width

3.35 in (85 mm)


Maximum Depth

5.12 in (130 mm)


Net Weight

3.51 lb(US) (1.59 kg)




Schneider Electric (Square D)