IC411 - TEFC, IP55, 404TC/405TC Frame, 230/460/380VAC 50/60Hz 3 Phase, 12408987, NEMA Premium Efficiency, Foot Mounted, C-Face, Cast Iron Frame, 2-7/8" Keyed Shaft







Electric Motors







































Frame 404/5TC
Output 100 HP (75 kW)
Number of Poles 4
Frequency 60 Hz
Rated speed 1780 rpm
Slip 1.11 %
Rated voltage 230/460 V
Rated current 226/113 A
L. R. Amperes 1627/814 A
LRC 7.2x(Code H)
No load current 86.0/43.0 A
Rated torque 295 ft.lb
Locked rotor torque 270 %
Breakdown torque 300 %
Locked rotor time 23s (cold) 13s (hot)




































Moment of inertia (J) 26.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.15
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 75.0 dB(A)
Approx. weight³ 1230 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.5 

95.0 

95.4 



Power factor















50% 75% 100%

0.72 

0.82 

0.87 









































Frame 404/5TC
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1480 rpm
Slip 1.33 %
Rated voltage 380 V
Rated current 103 A
L. R. Amperes 773 A
LRC 7.5x(Code H)
No load current 42.0 A
Rated torque 266 ft.lb
Locked rotor torque 270 %
Breakdown torque 310 %
Locked rotor time 21s (cold) 12s (hot)




































Moment of inertia (J) 26.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 1230 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

94.0 

94.5 

94.5 



Power factor















50% 75% 100%

0.69 

0.80 

0.86 









































Frame 404/5TC
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 400 V
Rated current 100 A
L. R. Amperes 840 A
LRC 8.4x(Code J)
No load current 46.0 A
Rated torque 265 ft.lb
Locked rotor torque 300 %
Breakdown torque 360 %
Locked rotor time 21s (cold) 12s (hot)




































Moment of inertia (J) 26.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 1230 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.6 

94.5 

94.5 



Power factor















50% 75% 100%

0.65 

0.77 

0.84 









































Frame 404/5TC
Output 75 HP (55 kW)
Number of Poles 4
Frequency 50 Hz
Rated speed 1485 rpm
Slip 1.00 %
Rated voltage 415 V
Rated current 98.7 A
L. R. Amperes 898 A
LRC 9.1x(Code K)
No load current 49.0 A
Rated torque 265 ft.lb
Locked rotor torque 320 %
Breakdown torque 370 %
Locked rotor time 21s (cold) 12s (hot)




































Moment of inertia (J) 26.4 sq.ft.lb
Design B
Insulation Class F
Service factor 1.00
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 70.0 dB(A)
Approx. weight³ 1230 lb






(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.




Efficiency















50% 75% 100%

93.6 

94.5 

94.5 



Power factor















50% 75% 100%

0.62 

0.75 

0.82 







Features












































Frame Material Cast Iron 
Impregnation Method Constant Resin Flow 
Regreasing System At Drive end and Non-drive end 
Main terminal box hole NPT 3" 
Terminal Block Without 
Shaft Locking Device Without 
Drain Sinterized, Exd 
Shaft Material SAE 4140 Carbon Steel 
Painting RAL 5009 202P (ISO 12944 - C4) 
Grounding Lugs Double 
Fan Cover material Cast Iron 
Tropicalized Painting Without 
Fan material Aluminum 
Bearing cap Yes- Bearing Cap 
Bolt Material Carbon Steel 
Winding thermal protection Thermostat - 2 wires 1 per phase 155°C 
Drip Cover Without 
Overload protector (phenolic) Without overload protector  