Electric Motors
| Frame | 326TC |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 60 Hz |
| Rated speed | 1775 rpm |
| Slip | 1.39 % |
| Rated voltage | 208-230/460 V |
| Rated current | 134-121/60.6 A |
| L. R. Amperes | 979-885/443 A |
| LRC | 7.3x(Code H) |
| No load current | 47.4-55.0/27.5 A |
| Rated torque | 146 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 280 % |
| Locked rotor time | 36s (cold) 20s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.15 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 71.0 dB(A) |
| Approx. weight³ | 696 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.6 |
94.5 |
94.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.65 |
0.76 |
0.81 |
| Frame | 326TC |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1475 rpm |
| Slip | 1.67 % |
| Rated voltage | 380 V |
| Rated current | 60.1 A |
| L. R. Amperes | 415 A |
| LRC | 6.9x(Code H) |
| No load current | 27.1 A |
| Rated torque | 140 ft.lb |
| Locked rotor torque | 240 % |
| Breakdown torque | 260 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 69.0 dB(A) |
| Approx. weight³ | 696 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.0 |
93.6 |
93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.65 |
0.76 |
0.81 |
| Frame | 326TC |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1480 rpm |
| Slip | 1.33 % |
| Rated voltage | 400 V |
| Rated current | 58.6 A |
| L. R. Amperes | 445 A |
| LRC | 7.6x(Code J) |
| No load current | 29.7 A |
| Rated torque | 140 ft.lb |
| Locked rotor torque | 260 % |
| Breakdown torque | 290 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 69.0 dB(A) |
| Approx. weight³ | 696 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
93.0 |
93.6 |
93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.60 |
0.73 |
0.79 |
| Frame | 326TC |
|---|---|
| Output | 40 HP (30 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1480 rpm |
| Slip | 1.33 % |
| Rated voltage | 415 V |
| Rated current | 58.7 A |
| L. R. Amperes | 470 A |
| LRC | 8.0x(Code K) |
| No load current | 31.8 A |
| Rated torque | 140 ft.lb |
| Locked rotor torque | 280 % |
| Breakdown torque | 310 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 9.16 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | W-6 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 69.0 dB(A) |
| Approx. weight³ | 696 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
|
92.4 |
93.6 |
93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
|
0.57 |
0.69 |
0.76 |
Features
| Frame Material | Cast Iron |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Regreasing System | At Drive end and Non-drive end |
| Main terminal box hole | NPT 2" |
| Terminal Block | Without |
| Shaft Locking Device | Without |
| Drain | Sinterized, Exd |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 5009 202P (ISO 12944 - C4) |
| Grounding Lugs | Single |
| Fan Cover material | Cast Iron |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | Yes- Bearing Cap |
| Bolt Material | Carbon Steel |
| Winding thermal protection | Thermostat - 2 wires 1 per phase 155°C |
| Balancing Method | 1/2 Key |
| Drip Cover | With |
| Overload protector (phenolic) | Without overload protector |