Description
Fuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.
Developed with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations
Fuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results.
Specifications
| Manufacturer | Fuji Electric |
|---|---|
| Model Number | FRN005AR1L-2U |
| Enclosure | UL/NEMA Type 12 IP55 |
| Voltage | 208/230VAC 60Hz |
| HP Rating | 2 HP with Single Phase Input 5 HP with 3-Phase Input |
| Rated Current | 7.0 Amps with Single Phase Input 18.0 Amps with 3-Phase Input |
| Weight | 22 lbs |
| Dimensions | 5.91" x 18.30" x 10.30" (W x H x D) |
| Warranty | 3 Years from date of shipment |
Detailed Specifications
| Nominal Applied Motor (Rated Output) | 1.5 HP with Single Phase Input at 208VAC 2 HP with Single Phase Input at 230VAC 5 HP with 3-Phase Input |
|---|---|
| Rated Output Capacity | 2.7 kVA with Single Phase Input 7.1 kVA with 3-Phase Input |
| Rated Output Current | 7.0 Amps with Single Phase Input 18.0 Amps with 3-Phase Input |
| Output Frequency | 120Hz Maximum |
| Output Stability | Analog Setting: ±0.2% of Maximum Frequency Digital Setting: ±0.01% of Maximum Frequency (By Keypad) |
| Rated Voltage | Three Phase, 200 to 240VAC (with AVR Function) |
| Output Overload Capability | 110% for 1 Minute (Overload capability interval : IEC 61800-2 compliant) |
| Rated Input Frequency | 50, 60 Hz |
| Main Power Supply Input | Three Phase, 200 to 240VAC, 50/60Hz |
| Rated Input Current | 12.9 Ampst |
| Required Input Power Supply Capacity | 3.0 kVA with Single Phase Input 5.2 kVA with 3-Phase Input |
| Auxiliary Control Power Supply | Single Phase, 200 to 240VAC, 50/60Hz |
| Auxiliary Main Power Supply | - |
| Voltage & Frequency Variations | Voltage: +10 to -15% Interphase Voltage Unbalance: 2% or less Frequency: +5 to -5% |
| Braking Torque | 20 % |
| DC Injection Braking | Starting frequency:0.0 to 60.0Hz Braking time:0.0 to 30.0s Braking level:0 to 60% |
| EMC Filter | Built-In EMC standards compliance : Category C2 (emission) / 2nd Env. (Immunity) |
| DC Reactor | Built-in (IEC/EN 61000-3-2, IEC/EN 61000-3-12) |
| Power Factor (at Rated Load) | >0.98 Displacement P.F. (cosf) >=0.90 True Power Factor |
| Efficiency | 97 % at Rated Load |
| Enclosure | IEC/EN 60529: IP55 UL 50: UL Type 12 |
| Cooling Method | Fan Cooling |
| Weight/Mass | 10 kg |
| Ambient Temperature | NEMA/UL Type 12: -10 to 40°C (14 to 104°F) |
| Storage Temperature | -25 to 70°C (-13 to 158°F) |
| Relative Humidity | 5 to 95% RH (Without Condensation) |
| Installation Location | IEC60664-1 Pollution Degree 2 (Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight) Indoor Use Only |
| Altitude | 0 to 3,300ft (1,000m) 3,300ft (1,000m) to 9,900ft (3,000m) with Derating |
Features
Control Inputs & Outputs
- 9 Digital Inputs: X1 – X7, FWD, & REV Programmable
67 Selectable Functions - 2 Safety Input (dedicated): EN1, EN2
- 3 Analog Inputs: (2) 0 to +10Vdc & (1) 4 to 20mA
- 6 Digital Outputs: (2) Relays (1 Form C & 1 Form A) & (4) Transistor
77 Selectable Functions - 2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA
43 Selectable Functions - 2 RS-485 Connections: RJ45 Keypad Port & RS485 Control Terminal Block Connections
- 24Vdc Output Terminal: Rated 200mA
- Keypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed
Robust Design
- Nickel (Ni) & Tin (Sn) Plated Bus Bars
- Conformal Coated PCBs
- Cooling Fan Board Coating + Anti-Rust Protection
- 10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal
Flexibility & Functionality
- Removable Control Terminal Block
- CE Filter Built-In for All Models
- DCR for All Models
- PC Programming & Troubleshooting Software
- USB Port on Control Card
- Real Time Clock
- Customizable Logic
- Automatic Energy Savings Control
- 4-PID Controllers
- Fire Mode
- Catch a Spinning Motor
- Filter Clogging Prevention/Reversing Operation
- Wet-Bulb Temperature Presumption Control
- Selectable “Light” Alarms
- PID Units of Measurement Display
- Password
- 3 Option Card Ports Built-In
- Single Phase Input
- BACnet MS/TP, Metasys N2, Modbus RTUD Embedded
Safety & Standards
- Safety Input
- UL 508C, CE
- UL Plenum Rating
- RoHS
- SEMI F47-0706
Codes and Standards
- UL508C
- C22.2 No.14,
- EN61800-5-1:2007
Options
- Ethernet
- CC-Link
- LONWORKS
- DeviceNet
- Profibus DP
- CANopen
Communication Options
- Keypad with USB Port
- Relay Output
- Analog Inputs and Outputs
- Temperature Sensor Input
I/O Options
Dimensions
| W | 150 mm 5.91" |
|---|---|
| H | 465 mm 18.31" |
| D | 262 mm 10.31" |
| D1 | 162 mm 6.38" |
| D2 | 100 mm 3.94" |
| W1 | 115 mm 4.53" |
| W2 | 17.5 mm 0.69" |
| H1 | 451 mm 17.76" |
| H2 | 7 mm 0.28" |
| H3 | - |
| M | 2x 8 mm diameter 2x 0.31" diameter |
| N | 8 mm 0.31" |
Links
FRENIC-HVAC Quick Reference Guide
FRENIC-HVAC Datasheet
FRENIC-HVAC Specifications
FRENIC-HVAC General Specifications
FRENIC-HVAC Engineering Specifications
FRENIC-HVAC Instruction Manual
FRENIC-HVAC User's Manual
FRENIC-HVAC Brochure
FRENIC-HVAC Catalog
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor