Catalog No 110086.00 Model M6C17FB11J  
Product type AC MOTOR Stock Stock
Description ..1/2HP..1725RPM.56.TEFC.115/230V.1PH.60HZ.CONT.40C.1.15SF.RIGID.M6C17FB11J.....AG - FARM DUTY/GENERAL PURPOSE.MANUAL.......
Information shown is for current motor's design
 Engineering Data
Volts 115 Volts 208-230 Volts  
F.L. Amps 8.8 F.L. Amps 4.4 F.L. Amps
S. F Amps 9.4 S. F Amps 4.7 S. F Amps

RPM 1800 Hertz 60    
HP 1/2 Duty CONTINUOUS TYPE CF
KW .37        
Frame 56 Serv. Factor 1.15 Phase 1
Max Amb 40 Design L Code L
Insul Class B Protection MANUAL Therm.Prot. CED4705
Eff 100% 66 Eff 75% PF 58
UL Y-(LEESON UL REC) CSA Yes Bearing OPE 6203
CC Number EXEMPT CE No Bearing PE 6203
Load Type Inverter Type Speed Range NONE

Motor Wt. 25 LB Enclosure TEFC Lubrication POLYREX EM
Nameplate 993500 Mounting RIGID Rotation SELECTIVE CCW
Assembly 042545 Shaft Dia. 5/8 IN Ext. Diag. 005003.03
Cust Part No Outline 028774-550A Ext. Diag2
Packaging B Winding C634257
Carton Label Leeson Farm Duty     GROUP:
Iris Paint RED (ENAMEL) Test Card 07

Form Factor   RMS Amps   Const Torque Speed Range  
Torque   Peak      
AB Code   Peak@DegC      
Resistance          
Connection          

Rework Status   Rework TYPE      

Hazardous Loc NONE  Brake Motors  
Explosion Proof   Temp Op Code FORCE
Class GROUP: VDC
Class GROUP: ADC
        Brake Coil OHMs @25 C
Performance
Torque UOM OZ-FT Inertia (WK²) .06 LB-FT^2  
Torque 24(Full Load) 67.3(Break Down) 64.5(Pull Up) 86.4(Locked Rotor)
CURRENT (amps) 4.36(Full Load) 0(Break Down) 0(Pull Up) 20.28(Locked Rotor)
Efficiency (%) 0(Full Load) 59.3(75% Load) 50.7(50% Load) 34.6(25% Load)
PowerFactor 58.1(Full Load) 51.7(75% Load) 42.9(50% Load) 32.6(25% Load)
Speed Torque Curve @ 60 Hz, 230 Volts
Curve Point Amps Amps(%) Torque Torque(%) RPM KW PF HP
FL 4.36 - 24.0 0.0 1746 0.585 58.1 0.5
BD - - 67.3 272.0 1475 - - 0.5
PU - - 64.5 262.0 1300 - - 0.5
LR 20.28 - 86.4 357.0 0.0 3.965 - 0.5
SOURCE: CALCULATED GROUP: 3
Load Curve Data @60 Hz, 230 Volts, 1/2 Horsepower
Load Amps KW RPM Torque EFF PF Rise By Resis Frame Rise
0.0 3.7 0.197 1792 0.0 0.0 23.1 0.0 -
0.25 3.65 0.274 1781 6.0 34.6 32.6 0.0 -
0.5 3.76 0.371 1767 12.0 50.7 42.9 0.0 -
0.75 3.97 0.472 1753 18.0 59.3 51.7 0.0 -
1.0 4.35 0.584 1728 24.0 63.0 58.4 84.0 50.0
1.25 4.64 0.695 1720 30.0 65.9 65.1 0.0 -
1.5 5.09 0.821 1699 36.0 66.1 70.1 0.0 -
SOURCE: CALCULATED GROUP: 3