Electric Motors
Frame | 143/5T |
---|---|
Output | 2 HP (1.5 kW) |
Number of Poles | 8/4 |
Frequency | 60 Hz |
Rated speed | 1735 rpm |
Slip | 3.61 % |
Rated voltage | 200 V |
Rated current | 6.39 A |
L. R. Amperes | 51.2 A |
LRC | 8.0x(Code K) |
No load current | 3.68 A |
Rated torque | 6.05 ft.lb |
Locked rotor torque | 270 % |
Breakdown torque | 300 % |
Locked rotor time | 10s (cold) 6s (hot) |
Moment of inertia (J) | 0.1590 sq.ft.lb |
---|---|
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 51.0 dB(A) |
Approx. weight³ | 2.2 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
77.0 | 81.5 | 82.5 |
Power factor
50% | 75% | 100% |
---|---|---|
0.60 | 0.73 | 0.82 |
Frame | 143/5T |
---|---|
Output | 0.5 HP (0.37 kW) |
Number of Poles | 8/4 |
Frequency | 60 Hz |
Rated speed | 860 rpm |
Slip | 4.44 % |
Rated voltage | 200 V |
Rated current | 2.88 A |
L. R. Amperes | 10.4 A |
LRC | 3.6x(Code J) |
No load current | 1.98 A |
Rated torque | 3.05 ft.lb |
Locked rotor torque | 180 % |
Breakdown torque | 229 % |
Locked rotor time | 50s (cold) 28s (hot) |
Moment of inertia (J) | 0.1590 sq.ft.lb |
---|---|
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 48.0 dB(A) |
Approx. weight³ | 2.2 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
55.0 | 62.0 | 64.0 |
Power factor
50% | 75% | 100% |
---|---|---|
0.37 | 0.48 | 0.58 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Double impregnation polyester |
Space Heater Voltage | 200 - 240 V |
Main terminal box hole | NPT 3/4" |
Terminal Block | Without |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | RAL 5009 202E (ISO 12944 - C4) |
Grounding Lugs | Single |
Fan Cover material | Steel |
Tropicalized Painting | Complete (200h) |
Joints Seal | Permatex |
Fan material | Plastic |
Bearing cap | No-Without Bearing Cap |
Drip Cover | Without |
Overload protector (phenolic) | Without overload protector |
Bearing details
Drive End | Non Drive End | |
---|---|---|
Bearing type | 6205 2RS | 6204 2RS |
Sealing | V'Ring | V'Ring |
Lubrication interval | - | - |
Lubricant amount | - | - |
Grease Type | Mobil Polyrex EM |
Foundation loads
Max. traction | Max. compression |
---|---|
60 lb | 62 lb |