Electric Motors
| Frame | 80 |
|---|---|
| Output | 1.5 HP (1.1 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2810 rpm |
| Slip | 6.33 % |
| Rated voltage | 220/380 V |
| Rated current | 4.09/2.37 A |
| L. R. Amperes | 30.3/17.5 A |
| LRC | 7.4 |
| No load current | 1.99/1.15 A |
| Rated torque | 2.77 ft.lb |
| Locked rotor torque | 330 % |
| Breakdown torque | 320 % |
| Locked rotor time | 41s (cold) 23s (hot) |
| Moment of inertia (J) | 0.0356 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 59.0 dB(A) |
| Approx. weight³ | 28.6 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 82.0 | 83.7 | 83.1 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.69 | 0.80 | 0.85 |
| Frame | 80 |
|---|---|
| Output | 1.5 HP (1.1 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2830 rpm |
| Slip | 5.67 % |
| Rated voltage | 230/400 V |
| Rated current | 4.03/2.32 A |
| L. R. Amperes | 29.9/17.2 A |
| LRC | 7.4 |
| No load current | 2.35/1.35 A |
| Rated torque | 2.75 ft.lb |
| Locked rotor torque | 360 % |
| Breakdown torque | 360 % |
| Locked rotor time | 41s (cold) 23s (hot) |
| Moment of inertia (J) | 0.0356 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 59.0 dB(A) |
| Approx. weight³ | 28.6 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 81.0 | 83.5 | 83.5 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.63 | 0.76 | 0.82 |
| Frame | 80 |
|---|---|
| Output | 1.5 HP (1.1 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2840 rpm |
| Slip | 5.33 % |
| Rated voltage | 240/415 V |
| Rated current | 4.01/2.32 A |
| L. R. Amperes | 29.7/17.2 A |
| LRC | 7.4 |
| No load current | 2.59/1.50 A |
| Rated torque | 2.74 ft.lb |
| Locked rotor torque | 390 % |
| Breakdown torque | 390 % |
| Locked rotor time | 41s (cold) 23s (hot) |
| Moment of inertia (J) | 0.0356 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 59.0 dB(A) |
| Approx. weight³ | 28.6 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 80.0 | 83.0 | 83.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.58 | 0.72 | 0.79 |
| Frame | 80 |
|---|---|
| Output | 1.5 HP (1.1 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3450 rpm |
| Slip | 4.17 % |
| Rated voltage | 460 V |
| Rated current | 2.03 A |
| L. R. Amperes | 17.1 A |
| LRC | 8.4 |
| No load current | 1.20 A |
| Rated torque | 2.25 ft.lb |
| Locked rotor torque | 530 % |
| Breakdown torque | 520 % |
| Locked rotor time | 48s (cold) 27s (hot) |
| Moment of inertia (J) | 0.0356 sq.ft.lb |
|---|---|
| Design | N |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | S1 |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | B3L(E) |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 62.0 dB(A) |
| Approx. weight³ | 28.6 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 78.5 | 81.5 | 84.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.62 | 0.74 | 0.81 |
Features
| Frame Material | Aluminum |
|---|---|
| Impregnation Method | Dip and Bake Polyester |
| Main terminal box hole | 2xM20x1,5 |
| Terminal Block | BMC - 6 pins |
| Shaft Locking Device | Without |
| Drain | Rubber, automatic |
| Shaft Material | SAE 1040/45 Carbon Steel |
| Painting | RAL 5009 207A (ISO 12944 - C2) |
| Grounding Lugs | Single |
| Fan Cover material | Steel |
| Tropicalized Painting | Without |
| Fan material | Plastic |
| Bearing cap | No-Without Bearing Cap |
| Balancing Method | Not Balanced |
| Drip Cover | Without |
Product title