00536ET3E184JP-W22 WEG 5HP JP Close Coupled Pump Electric Motor, 3600RPM

$886.14 $1,094.00 Save $207.86

Shipping calculated at checkout

WEG Electric Corporation SKU: 00536ET3E184JP-W22 Barcode: 7909018389837

30 Day
Return Policy

Ships Fast
in 24 hours

In stock!

Electric Motors

Frame 182/4JP
Output 5 HP (3.7 kW)
Number of Poles 2
Frequency 60 Hz
Rated speed 3485 rpm
Slip 3.19 %
Rated voltage 230/460 V
Rated current 11.8/5.90 A
L. R. Amperes 89.7/44.8 A
LRC 7.6x(Code J)
No load current 4.00/2.00 A
Rated torque 7.53 ft.lb
Locked rotor torque 229 %
Breakdown torque 350 %
Locked rotor time 45s (cold) 25s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 66.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.5  88.5  88.5 

Power factor

50% 75% 100%
0.76  0.85  0.89 
Frame 182/4JP
Output 4 HP (3 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2890 rpm
Slip 3.67 %
Rated voltage 380 V
Rated current 5.79 A
L. R. Amperes 42.8 A
LRC 7.4x(Code H)
No load current 2.00 A
Rated torque 7.27 ft.lb
Locked rotor torque 229 %
Breakdown torque 320 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.3  87.7  87.5 

Power factor

50% 75% 100%
0.74  0.85  0.90 
Frame 182/4JP
Output 4 HP (3 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2900 rpm
Slip 3.33 %
Rated voltage 400 V
Rated current 5.57 A
L. R. Amperes 45.1 A
LRC 8.1x(Code J)
No load current 2.15 A
Rated torque 7.24 ft.lb
Locked rotor torque 270 %
Breakdown torque 370 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.3  88.2  88.3 

Power factor

50% 75% 100%
0.71  0.83  0.88 
Frame 182/4JP
Output 4 HP (3 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2910 rpm
Slip 3.00 %
Rated voltage 415 V
Rated current 5.43 A
L. R. Amperes 48.3 A
LRC 8.9x(Code K)
No load current 2.25 A
Rated torque 7.22 ft.lb
Locked rotor torque 300 %
Breakdown torque 400 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
86.1  88.2  88.3 

Power factor

50% 75% 100%
0.68  0.81  0.87 
Frame 182/4JP
Output 5 HP (3.7 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2850 rpm
Slip 5.00 %
Rated voltage 380 V
Rated current 7.14 A
L. R. Amperes 42.1 A
LRC 5.9x(Code F)
No load current 2.00 A
Rated torque 9.21 ft.lb
Locked rotor torque 180 %
Breakdown torque 250 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  87.5  86.5 

Power factor

50% 75% 100%
0.81  0.88  0.91 
Frame 182/4JP
Output 5 HP (3.7 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2870 rpm
Slip 4.33 %
Rated voltage 400 V
Rated current 6.78 A
L. R. Amperes 44.7 A
LRC 6.6x(Code G)
No load current 2.15 A
Rated torque 9.15 ft.lb
Locked rotor torque 210 %
Breakdown torque 290 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B
Insulation Class F
Service factor 1.25
Temperature rise 80 K
Duty Cycle Cont.(S1)
Starting Method Direct On Line
Ambient temperature -20°C to +40°C
Altitude 1000 m.a.s.l.
Degree of Protection IP55
Enclosure IC411 - TEFC
Mounting F-1
Rotation¹ Both (CW and CCW)
Noise level² 62.0 dB(A)
Approx. weight³ 95.8 lb
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.

Efficiency

50% 75% 100%
87.5  88.5  87.5 

Power factor

50% 75% 100%
0.78  0.87  0.90 
Frame 182/4JP
Output 5 HP (3.7 kW)
Number of Poles 2
Frequency 50 Hz
Rated speed 2880 rpm
Slip 4.00 %
Rated voltage 415 V
Rated current 6.61 A
L. R. Amperes 47.6 A
LRC 7.2x(Code H)
No load current 2.25 A
Rated torque 9.12 ft.lb
Locked rotor torque 240 %
Breakdown torque 320 %
Locked rotor time 32s (cold) 18s (hot)
Moment of inertia (J) 0.2233 sq.ft.lb
Design B