Electric Motors
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 8 |
| Frequency | 60 Hz |
| Rated speed | 880 rpm |
| Slip | 2.22 % |
| Rated voltage | 230/460 V |
| Rated current | 146/73.0 A |
| L. R. Amperes | 949/475 A |
| LRC | 6.5x(Code H) |
| No load current | 60.0/30.0 A |
| Rated torque | 358 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 270 % |
| Locked rotor time | 23s (cold) 13s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 60.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.0 | 93.0 | 93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.68 | 0.78 | 0.83 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 725 rpm |
| Slip | 3.33 % |
| Rated voltage | 380 V |
| Rated current | 72.9 A |
| L. R. Amperes | 445 A |
| LRC | 6.1x(Code G) |
| No load current | 29.7 A |
| Rated torque | 362 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 250 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 56.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 92.1 | 91.8 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.67 | 0.79 | 0.84 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 730 rpm |
| Slip | 2.67 % |
| Rated voltage | 400 V |
| Rated current | 70.9 A |
| L. R. Amperes | 475 A |
| LRC | 6.7x(Code H) |
| No load current | 32.0 A |
| Rated torque | 360 ft.lb |
| Locked rotor torque | 210 % |
| Breakdown torque | 290 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 56.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.9 | 92.1 | 91.8 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.64 | 0.77 | 0.82 |
| Frame | 404/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 730 rpm |
| Slip | 2.67 % |
| Rated voltage | 415 V |
| Rated current | 69.2 A |
| L. R. Amperes | 505 A |
| LRC | 7.3x(Code J) |
| No load current | 33.9 A |
| Rated torque | 360 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 310 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 56.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.9 | 92.2 | 91.8 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.61 | 0.74 | 0.81 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 720 rpm |
| Slip | 4.00 % |
| Rated voltage | 380 V |
| Rated current | 89.2 A |
| L. R. Amperes | 455 A |
| LRC | 5.1x(Code E) |
| No load current | 29.7 A |
| Rated torque | 438 ft.lb |
| Locked rotor torque | 150 % |
| Breakdown torque | 210 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 56.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 91.7 | 90.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.74 | 0.82 | 0.85 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 725 rpm |
| Slip | 3.33 % |
| Rated voltage | 400 V |
| Rated current | 85.0 A |
| L. R. Amperes | 485 A |
| LRC | 5.7x(Code F) |
| No load current | 32.0 A |
| Rated torque | 435 ft.lb |
| Locked rotor torque | 170 % |
| Breakdown torque | 240 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 56.0 dB(A) |
| Approx. weight³ | 1149 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 91.7 | 91.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.71 | 0.80 | 0.84 |
| Frame | 404/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 8 |
| Frequency | 50 Hz |
| Rated speed | 725 rpm |
| Slip | 3.33 % |
| Rated voltage | 415 V |
| Rated current | 82.9 A |
| L. R. Amperes | 514 A |
| LRC | 6.2x(Code G) |
| No load current | 33.9 A |
| Rated torque | 435 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 260 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 40.2 sq.ft.lb |
|---|---|
| Design | B |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor