Electric Motors
| Frame | 364/5JM |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 2 |
| Frequency | 60 Hz |
| Rated speed | 3560 rpm |
| Slip | 1.11 % |
| Rated voltage | 230/460 V |
| Rated current | 134/67.0 A |
| L. R. Amperes | 884/442 A |
| LRC | 6.6x(Code G) |
| No load current | 30.0/15.0 A |
| Rated torque | 88.5 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 260 % |
| Locked rotor time | 25s (cold) 14s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 79.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.7 | 93.0 | 93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.81 | 0.88 | 0.90 |
| Frame | 364/5JM |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2955 rpm |
| Slip | 1.50 % |
| Rated voltage | 380 V |
| Rated current | 65.9 A |
| L. R. Amperes | 415 A |
| LRC | 6.3x(Code F) |
| No load current | 15.0 A |
| Rated torque | 88.9 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 250 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 74.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.1 | 92.8 | 93.7 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.81 | 0.88 | 0.91 |
| Frame | 364/5JM |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2960 rpm |
| Slip | 1.33 % |
| Rated voltage | 400 V |
| Rated current | 63.3 A |
| L. R. Amperes | 443 A |
| LRC | 7.0x(Code G) |
| No load current | 16.2 A |
| Rated torque | 88.7 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 280 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 74.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.7 | 92.8 | 93.7 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.79 | 0.87 | 0.90 |
| Frame | 364/5JM |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2965 rpm |
| Slip | 1.17 % |
| Rated voltage | 415 V |
| Rated current | 61.7 A |
| L. R. Amperes | 457 A |
| LRC | 7.4x(Code H) |
| No load current | 17.4 A |
| Rated torque | 88.6 ft.lb |
| Locked rotor torque | 229 % |
| Breakdown torque | 300 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 74.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 91.6 | 92.9 | 93.7 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.76 | 0.85 | 0.89 |
| Frame | 364/5JM |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2945 rpm |
| Slip | 1.83 % |
| Rated voltage | 380 V |
| Rated current | 81.3 A |
| L. R. Amperes | 423 A |
| LRC | 5.2x(Code E) |
| No load current | 15.0 A |
| Rated torque | 107 ft.lb |
| Locked rotor torque | 160 % |
| Breakdown torque | 210 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 74.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 93.0 | 92.4 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.85 | 0.90 | 0.91 |
| Frame | 364/5JM |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2950 rpm |
| Slip | 1.67 % |
| Rated voltage | 400 V |
| Rated current | 77.6 A |
| L. R. Amperes | 450 A |
| LRC | 5.8x(Code F) |
| No load current | 16.2 A |
| Rated torque | 107 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 229 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 74.0 dB(A) |
| Approx. weight³ | 877 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 92.4 | 93.0 | 93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.83 | 0.89 | 0.90 |
| Frame | 364/5JM |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 2 |
| Frequency | 50 Hz |
| Rated speed | 2955 rpm |
| Slip | 1.50 % |
| Rated voltage | 415 V |
| Rated current | 74.8 A |
| L. R. Amperes | 464 A |
| LRC | 6.2x(Code F) |
| No load current | 17.4 A |
| Rated torque | 107 ft.lb |
| Locked rotor torque | 190 % |
| Breakdown torque | 250 % |
| Locked rotor time | 21s (cold) 12s (hot) |
| Moment of inertia (J) | 10.6 sq.ft.lb |
|---|---|
| Design | B |
Product title