Electric Motors
| Frame | 364/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 4 |
| Frequency | 60 Hz |
| Rated speed | 1780 rpm |
| Slip | 1.11 % |
| Rated voltage | 460 V |
| Rated current | 71.6 A |
| L. R. Amperes | 444 A |
| LRC | 6.2x(Code G) |
| No load current | 26.0 A |
| Rated torque | 177 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 240 % |
| Locked rotor time | 27s (cold) 15s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.25 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 67.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 94.5 | 95.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.71 | 0.80 | 0.83 |
| Frame | 364/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1480 rpm |
| Slip | 1.33 % |
| Rated voltage | 380 V |
| Rated current | 71.0 A |
| L. R. Amperes | 447 A |
| LRC | 6.3x(Code G) |
| No load current | 25.0 A |
| Rated torque | 177 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 240 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.7 | 93.9 | 94.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.71 | 0.80 | 0.84 |
| Frame | 364/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1480 rpm |
| Slip | 1.33 % |
| Rated voltage | 400 V |
| Rated current | 69.1 A |
| L. R. Amperes | 477 A |
| LRC | 6.9x(Code H) |
| No load current | 27.5 A |
| Rated torque | 177 ft.lb |
| Locked rotor torque | 220 % |
| Breakdown torque | 260 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.3 | 93.9 | 94.2 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.68 | 0.78 | 0.82 |
| Frame | 364/5T |
|---|---|
| Output | 50 HP (37 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1485 rpm |
| Slip | 1.00 % |
| Rated voltage | 415 V |
| Rated current | 67.4 A |
| L. R. Amperes | 499 A |
| LRC | 7.4x(Code J) |
| No load current | 30.0 A |
| Rated torque | 177 ft.lb |
| Locked rotor torque | 240 % |
| Breakdown torque | 280 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 80 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 93.4 | 94.2 | 94.3 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.65 | 0.76 | 0.81 |
| Frame | 364/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1470 rpm |
| Slip | 2.00 % |
| Rated voltage | 380 V |
| Rated current | 86.5 A |
| L. R. Amperes | 450 A |
| LRC | 5.2x(Code E) |
| No load current | 23.8 A |
| Rated torque | 214 ft.lb |
| Locked rotor torque | 160 % |
| Breakdown torque | 200 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 93.6 | 93.0 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.76 | 0.82 | 0.85 |
| Frame | 364/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1475 rpm |
| Slip | 1.67 % |
| Rated voltage | 400 V |
| Rated current | 82.6 A |
| L. R. Amperes | 479 A |
| LRC | 5.8x(Code F) |
| No load current | 25.3 A |
| Rated torque | 214 ft.lb |
| Locked rotor torque | 180 % |
| Breakdown torque | 210 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |
| Service factor | 1.00 |
| Temperature rise | 105 K |
| Duty Cycle | Cont.(S1) |
| Starting Method | Direct On Line |
| Ambient temperature | -20°C to +40°C |
| Altitude | 1000 m.a.s.l. |
| Degree of Protection | IP55 |
| Enclosure | IC411 - TEFC |
| Mounting | F-1 |
| Rotation¹ | Both (CW and CCW) |
| Noise level² | 63.0 dB(A) |
| Approx. weight³ | 890 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
| 50% | 75% | 100% |
|---|---|---|
| 94.1 | 93.6 | 93.6 |
Power factor
| 50% | 75% | 100% |
|---|---|---|
| 0.73 | 0.81 | 0.84 |
| Frame | 364/5T |
|---|---|
| Output | 60 HP (45 kW) |
| Number of Poles | 4 |
| Frequency | 50 Hz |
| Rated speed | 1480 rpm |
| Slip | 1.33 % |
| Rated voltage | 415 V |
| Rated current | 80.2 A |
| L. R. Amperes | 497 A |
| LRC | 6.2x(Code G) |
| No load current | 30.0 A |
| Rated torque | 213 ft.lb |
| Locked rotor torque | 200 % |
| Breakdown torque | 229 % |
| Locked rotor time | 18s (cold) 10s (hot) |
| Moment of inertia (J) | 22.4 sq.ft.lb |
|---|---|
| Design | B |
| Insulation Class | F |