Electric Motors
Frame | 324T |
---|---|
Output | 30 HP (22 kW) |
Number of Poles | 8/4 |
Frequency | 60 Hz |
Rated speed | 1780 rpm |
Slip | 1.11 % |
Rated voltage | 460 V |
Rated current | 37.2 A |
L. R. Amperes | 301 A |
LRC | 8.1x(Code J) |
No load current | 17.0 A |
Rated torque | 88.5 ft.lb |
Locked rotor torque | 270 % |
Breakdown torque | 280 % |
Locked rotor time | 19s (cold) 11s (hot) |
Moment of inertia (J) | 7.85 sq.ft.lb |
---|---|
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-2 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 69.0 dB(A) |
Approx. weight³ | 539 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
90.2 | 91.0 | 91.7 |
Power factor
50% | 75% | 100% |
---|---|---|
0.64 | 0.75 | 0.81 |
Frame | 324T |
---|---|
Output | 7.5 HP (5.5 kW) |
Number of Poles | 8/4 |
Frequency | 60 Hz |
Rated speed | 885 rpm |
Slip | 1.67 % |
Rated voltage | 460 V |
Rated current | 14.2 A |
L. R. Amperes | 51.0 A |
LRC | 3.6x(Code F) |
No load current | 8.80 A |
Rated torque | 44.5 ft.lb |
Locked rotor torque | 160 % |
Breakdown torque | 170 % |
Locked rotor time | 90s (cold) 50s (hot) |
Moment of inertia (J) | 7.85 sq.ft.lb |
---|---|
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP55 |
Enclosure | IC411 - TEFC |
Mounting | F-2 |
Rotation¹ | Both (CW and CCW) |
Noise level² | 56.0 dB(A) |
Approx. weight³ | 539 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
82.5 | 84.0 | 85.5 |
Power factor
50% | 75% | 100% |
---|---|---|
0.38 | 0.50 | 0.57 |
Features
Frame Material | Cast Iron |
---|---|
Impregnation Method | Double impregnation polyester |
Space Heater Voltage | 110-127/200-240 V |
Main terminal box hole | NPT 2" |
Terminal Block | Without |
Shaft Locking Device | Without |
Drain | Rubber, automatic |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | RAL 5009 202E (ISO 12944 - C4) |
Grounding Lugs | Single |
Fan Cover material | Cast Iron |
Tropicalized Painting | Complete (200h) |
Joints Seal | Permatex |
Fan material | Plastic |
Bearing cap | Yes- Bearing Cap |
Drip Cover | Without |
Overload protector (phenolic) | Without overload protector |
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor
$19.99 USD | $24.99 USD
Product title
Vendor