Electric Motors
Frame | E56 |
---|---|
Output | 0.550 kW (0.75 HP) |
Number of Poles | 6/4 |
Frequency | 60 Hz |
Rated speed | 1725 rpm |
Slip | 4.17 % |
Rated voltage | 115 V |
Rated current | 10.3 A |
L. R. Amperes | 35.0 A |
LRC | 3.4x(Code F) |
No load current | 7.80 A |
Rated torque | 2.25 ft.lb |
Locked rotor torque | 110 % |
Breakdown torque | 229 % |
Locked rotor time | 10s (cold) 6s (hot) |
Moment of inertia (J) | 0.0890 sq.ft.lb |
---|---|
Insulation Class | B |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP21 |
Enclosure | IC01 - ODP |
Mounting | F-1 |
Rotation¹ | CW |
Noise level² | 46.0 dB(A) |
Approx. weight³ | 24.3 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
54.5 | 61.0 | 61.1 |
Power factor
50% | 75% | 100% |
---|---|---|
0.54 | 0.66 | 0.75 |
Frame | E56 |
---|---|
Output | 0.18 kW (0.25 HP) |
Number of Poles | 6/4 |
Frequency | 60 Hz |
Rated speed | 1140 rpm |
Slip | 5.00 % |
Rated voltage | 115 V |
Rated current | 5.10 A |
L. R. Amperes | 0.000 A |
LRC | 0.0x(Code A) |
No load current | 4.95 A |
Rated torque | 1.11 ft.lb |
Locked rotor torque | 0 % |
Breakdown torque | 260 % |
Locked rotor time | 10s (cold) 6s (hot) |
Moment of inertia (J) | 0.0890 sq.ft.lb |
---|---|
Insulation Class | B |
Service factor | 1.00 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Degree of Protection | IP21 |
Enclosure | IC01 - ODP |
Mounting | F-1 |
Rotation¹ | CW |
Noise level² | 42.0 dB(A) |
Approx. weight³ | 24.3 lb |
(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.
Efficiency
50% | 75% | 100% |
---|---|---|
32.1 | 39.8 | 42.9 |
Power factor
50% | 75% | 100% |
---|---|---|
0.51 | 0.61 | 0.70 |
Features
Frame Material | Rolled Steel |
---|---|
Impregnation Method | Dip and Bake Polyester |
Shaft Locking Device | Without |
Shaft Material | SAE 1040/45 Carbon Steel |
Painting | Only primer |
Grounding Lugs | Single |
Fan Cover material | Without Fan Cover |
Tropicalized Painting | Without |
Fan material | Without fan |
Bearing cap | No-Without Bearing Cap |
Winding thermal protection | Thermostat - 2 wires 1 per phase 130°C |
Balancing Method | Not Balanced |
Drip Cover | Without |
Resilient Base | Without |
Overload protector (phenolic) | Without overload protector |
Product title