{"product_id":"opc-eth-fuji-ethernet-communication-card-1","title":"OPC-ETH Fuji EtherNet Communication Card","description":"\u003chtmlonly\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"10\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\u003cp\u003eThe OPC-ETH multiprotocol communication interface provides Ethernet-based network connectivity to Fuji FRENIC-MEGA and FRENIC-HVAC adjustable speed drives.\u003c\/p\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eThe OPC-ETH currently provides support for the following Ethernet networks:\u003cbr\u003e• \u003cstrong\u003eModbus\/TCP\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eBACnet\/IP\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eAllen Bradley CSP (also known as \"PCCC\" and \"AB Ethernet\")\u003c\/strong\u003e\n\u003c\/td\u003e\u003c\/tr\u003e \r\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"fontDarkBlue\"\u003e\u003cb\u003eDocuments\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"bgCCGray\"\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"10\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eBrochure\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OPC-ETH_brochure.pdf\" class=\"link2\"\u003eOPC-ETH Brochure (PDF, 1 Page, 304 KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eManual\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH%20User%27s%20Manual.pdf\" class=\"link2\"\u003eOPC-ETH User's Manual - Applicable for HVAC drive (PDF, 102 Pages, 7.37MB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OPC-G1-ETH_User_s_Manual.pdf\" class=\"link2\"\u003eOPC-ETH User's Manual - Applicable for MEGA drive (PDF, 99 Pages, 5.65MB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH%20Quick%20Installation%20Guide.pdf\" class=\"link2\"\u003eQuick Installation Guide (PDF, 2 Pages, 744KB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/funccodereglist.zip\" class=\"link2\"\u003eFunction Code Register List (ZIP, 1MB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RS485_Manual_df0fa9d6-0e6c-41ec-ba57-6b44965c0d69.pdf\" class=\"link2\"\u003eRS-485 User's Manual 24A7-E-0082 - Applicable for the OPC-ETH (PDF, 171 Pages, 1.83MB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eVersion Information\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH%20Version%20Info.pdf\" class=\"link2\"\u003eOPC-ETH Version Info (PDF, 3 Pages, 223KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eSample Application Programs\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/RSLogix_5000_Examples.zip\" class=\"link2\"\u003eRSLogix 5000 Examples (ZIP, 1.59MB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH_RSLogix_5000_Add-On_Instructions.zip\" class=\"link2\"\u003eRSLogix 5000 Add-On Instructions (ZIP, 516KB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/RSLogix_500_Examples.zip\" class=\"link2\"\u003eRSLogix 500 Examples (ZIP, 53KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eNetwork Documents\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH.ZIP\" class=\"link2\"\u003eOPC-ETH EDS (ZIP, 3KB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH.ico\" class=\"link2\"\u003eOPC-ETH EDS icon (ICO, 61KB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/XTPro%20Specification.pdf\" class=\"link2\"\u003eXTPro Specification (PDF, 20 Pages, 249KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eCertificates\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/11134_DOC_013013.pdf\" class=\"link2\"\u003eEtherNet\/IP Declaration of Conformance (PDF, 1 Page, 84KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eWeb Server\u003c\/b\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/Web_Server_V6.zip\" class=\"link2\"\u003eDefault Web Server, Version 6 (ZIP, 281KB)\u003c\/a\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/XTPro_Example.zip\" class=\"link2\"\u003eXTPro example (ZIP, 599KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"fontDarkBlue\"\u003e\u003cb\u003eSoftware\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"bgCCGray\"\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"10\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd width=\"100%\"\u003e• \u003ca href=\"https:\/\/iccdesigns.com\/downloads\/fujifinder\/index.html\" class=\"link2\"\u003eFuji Finder\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"fontDarkBlue\"\u003e\u003cb\u003eFirmware\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"bgCCGray\"\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"10\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd width=\"100%\"\u003e\n\u003cspan class=\"style1\" style=\"color: #ff0000;\"\u003eCAUTION: Do not attempt to downgrade the firmware to an earlier version!\u003c\/span\u003e\u003cbr\u003e• \u003ca href=\"https:\/\/www.witmermotorservice.com\/static\/files\/Fuji\/OPC-ETH\/OPC-ETH_eth_v1046.zip\" class=\"link2\"\u003eOPC-ETH V1.046 firmware (ZIP, 269KB)\u003c\/a\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"fontDarkBlue\"\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"bgCCGray\"\u003e • \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd valign=\"top\"\u003e\u003ctable width=\"100%\" cellpadding=\"0\" cellspacing=\"10\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eNetwork\u003c\/b\u003e\u003cbr\u003e• Dual-port RJ-45 with embedded IEEE 802.3 10BASE-T\/100BASE-TX Ethernet switch supports traditional star and daisy-chain topologies. Shielded RJ-45 connectors accept standard CAT5-type 8-conductor unshielded twisted-pair (UTP) patch cables.\u003cbr\u003e• MDI\/MDI-X auto-crossover allows the use of any combination of straight-through and cross-over Ethernet cables.\u003cbr\u003e• Supports multiple protocols simultaneously.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eUSB\u003c\/b\u003e\u003cbr\u003e• USB 2.0 port with mini-B connector provides composite USB device functionality. USB connection allows for product identification and firmware updating.\u003cbr\u003e• Enumerates as a standard USB mass storage device (\"flash drive\") for configuration file copying and web page customization.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eCustom Embedded Web Server\u003c\/b\u003e\u003cbr\u003e• Open XML-based socket data transfer allows end users to create their own custom web server content and load it onto the unit's internal file system via USB.\u003cbr\u003e• The factory-default web server provides configuration and real-time inverter function code monitoring\/control via standard web browsers such as Microsoft Internet Explorer and Mozilla Firefox.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eAlarms\u003c\/b\u003e\u003cbr\u003e• Monitor any available inverter function code and send emails to up to four recipients when a certain condition is detected. Twenty individually-configurable alarms are available.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eNetwork Timeout Action\u003c\/b\u003e\u003cbr\u003e• A configurable network timeout action can be programmed that allows function codes to have their own unique \"fail-safe\" conditions in the event of a network interruption.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eXML Configuration File Upload\/Download \u003c\/b\u003e\u003cbr\u003e• All interface configuration files are stored in the unit's internal filesystem in XML format.  These files can be transferred to\/from a PC via USB, which provides the capability for PC-based file backup and easy configuration copying to multiple units.  Configuration files can also be viewed and edited via standard text editors, XML editors and web browsers.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eDashboard\u003c\/b\u003e\u003cbr\u003e• A variety of gauges, meters, and graphs  can be configured to provide an at-a-glance graphical overview of critical application variables in real-time. A total of ten gauge windows are available (two at a time) and each gauge window can be configured to display one of six different gauge types.\u003cbr\u003e• A virtual keypad interface provides quick access to control and monitor information.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eIndicators\u003c\/b\u003e\u003cbr\u003e• 1 bicolor red\/green module status LED.\u003cbr\u003e• 1 bicolor red\/green network status LED.\u003cbr\u003e• 2 Ethernet speed LEDs.\u003cbr\u003e• 2 Ethernet link\/activity LEDs.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eField-Upgradeable\u003c\/b\u003e\u003cbr\u003e• As new firmware becomes available, the  unit can be upgraded in the field by the end-user.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cb\u003eROHS Compliant\u003c\/b\u003e\u003cbr\u003e• The OPC-ETH is lead-free.\r\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":67594685218909,"sku":"OPC-CP-ETM","price":150.5,"currency_code":"USD","in_stock":false}],"url":"https:\/\/witmermotor.com\/products\/opc-eth-fuji-ethernet-communication-card-1","provider":"Witmer Motor Service","version":"1.0","type":"link"}