{"title":"SWHD150 1.5HP Dual Seal","description":"","products":[{"product_id":"swhd150m2-20-ashland-1-5hp-dual-seal-sewage-pump-230vac-single-phase","title":"SWHD150M2-20 Ashland 1.5HP Dual Seal Sewage Pump, 230VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty cast iron construction\u003c\/li\u003e\n\u003cli\u003eOil-filled continuous duty rated PSC\/Induction motor\u003c\/li\u003e\n\u003cli\u003e9 Vane vortex cast iron impeller\u003c\/li\u003e\n\u003cli\u003e2ï¿½ solids handling\u003c\/li\u003e\n\u003cli\u003e2ï¿½ NPT Flanged Discharge\u003c\/li\u003e\n\u003cli\u003eMechanical Carbon Ceramic Seal\u003c\/li\u003e\n\u003cli\u003e20ï¿½ Cord\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eAshland Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSWHD150M2-20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003e230VAC 60Hz Single Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNEMA Start Code\u003c\/th\u003e\n\u003cth\u003eP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003cth\u003e13.8 Amps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Power Size\u003c\/th\u003e\n\u003cth\u003e14AWG\/3C \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Type\u003c\/th\u003e\n\u003cth\u003eSOW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord O.D.\u003c\/th\u003e\n\u003cth\u003e0.58\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDischarge Size\u003c\/th\u003e\n\u003cth\u003e2\" NPT Flanged\u003cbr\u003e3ï¿½ NPT Optional\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller Type\u003c\/th\u003e\n\u003cth\u003e9-Vane Vortex\u003cbr\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003cth\u003e20'\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolids Handling\u003c\/th\u003e\n\u003cth\u003e2\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Liquid Temperature\u003c\/th\u003e\n\u003cth\u003e104ï¿½F - Intermittent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceptable pH Range\u003c\/th\u003e\n\u003cth\u003e6 - 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Housing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCasing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft\u003c\/th\u003e\n\u003cth\u003eSS416\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003cth\u003eSST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-Rings\u003c\/th\u003e\n\u003cth\u003eNBR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Seal\u003c\/th\u003e\n\u003cth\u003eDual Mechanical\u003cbr\u003eCarbon Ceramic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Type\u003c\/th\u003e\n\u003cth\u003ePSC (Single Phase)\u003cbr\u003eInduction (3 Phase)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGen Insulation Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStator Winding Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Stator Temperature\u003c\/th\u003e\n\u003cth\u003e130ï¿½C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003e+\/-10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Protection\u003c\/th\u003e\n\u003cth\u003eThermally Protected\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService Factor\u003c\/th\u003e\n\u003cth\u003e1.00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SWHD150_Dimensions.webp\" alt=\"SWHD150 Pump Dimensions\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003ePerformance Curve\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SSHD150_Performance.webp\" alt=\"SWHD150 Performance Curve Graph\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_electrical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Electrical Data (PDF, 1 page, 126KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_features.pdf\" target=\"_blank\"\u003eAshland SWHD150 Features (PDF, 1 page, 231KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_performance_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Performance Data (PDF, 1 page, 82KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_technical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Technical Data (PDF, 1 page, 135KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_sewage_spec.pdf\" target=\"_blank\"\u003eAshland SWHD150 Catalog Sheet (PDF, 2 pages, 491KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_dimensional_data.pdf\" target=\"_blank\"\u003e Ashland SWHD150 Dimensional Data (PDF, 1 page, 203KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swh50100150200_and_swhd100150200_series_sewage_operating_manual.pdf\" target=\"_blank\"\u003e Ashland DWH50, SWH100, SWG150, SWH200, SWHD100, SWHD150 \u0026amp; SWHD200 Operation, Performance Specifications and Parts Manual (PDF, 51 pages, 2.73MB)\u003c\/a\u003e\u003cbr\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Ashland Pump","offers":[{"title":"Default Title","offer_id":43915835277405,"sku":"SWHD150M2-20","price":1788.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/0Q4O9835TTS1ANB0.jpg?v=1766452930"},{"product_id":"swhd150m3-20-ashland-1-5hp-dual-seal-sewage-pump-230vac-3-phase","title":"SWHD150M3-20 Ashland 1.5HP Dual Seal Sewage Pump, 230VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty cast iron construction\u003c\/li\u003e\n\u003cli\u003eOil-filled continuous duty rated PSC\/Induction motor\u003c\/li\u003e\n\u003cli\u003e9 Vane vortex cast iron impeller\u003c\/li\u003e\n\u003cli\u003e2ï¿½ solids handling\u003c\/li\u003e\n\u003cli\u003e2ï¿½ NPT Flanged Discharge\u003c\/li\u003e\n\u003cli\u003eMechanical Carbon Ceramic Seal\u003c\/li\u003e\n\u003cli\u003e20ï¿½ Cord\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eAshland Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSWHD150M3-20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003e230VAC 60Hz 3 Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNEMA Start Code\u003c\/th\u003e\n\u003cth\u003eP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003cth\u003e7.6 Amps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Power Size\u003c\/th\u003e\n\u003cth\u003e16AWG\/4C \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Type\u003c\/th\u003e\n\u003cth\u003eSOW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord O.D.\u003c\/th\u003e\n\u003cth\u003e0.46\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDischarge Size\u003c\/th\u003e\n\u003cth\u003e2\" NPT Flanged\u003cbr\u003e3ï¿½ NPT Optional\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller Type\u003c\/th\u003e\n\u003cth\u003e9-Vane Vortex\u003cbr\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003cth\u003e20'\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolids Handling\u003c\/th\u003e\n\u003cth\u003e2\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Liquid Temperature\u003c\/th\u003e\n\u003cth\u003e104ï¿½F - Intermittent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceptable pH Range\u003c\/th\u003e\n\u003cth\u003e6 - 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Housing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCasing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft\u003c\/th\u003e\n\u003cth\u003eSS416\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003cth\u003eSST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-Rings\u003c\/th\u003e\n\u003cth\u003eNBR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Seal\u003c\/th\u003e\n\u003cth\u003eDual Mechanical\u003cbr\u003eCarbon Ceramic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Type\u003c\/th\u003e\n\u003cth\u003ePSC (Single Phase)\u003cbr\u003eInduction (3 Phase)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGen Insulation Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStator Winding Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Stator Temperature\u003c\/th\u003e\n\u003cth\u003e130ï¿½C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003e+\/-10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Protection\u003c\/th\u003e\n\u003cth\u003eThermally Protected\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService Factor\u003c\/th\u003e\n\u003cth\u003e1.00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SWHD150_Dimensions.webp\" alt=\"SWHD150 Pump Dimensions\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003ePerformance Curve\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SSHD150_Performance.webp\" alt=\"SWHD150 Performance Curve Graph\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_electrical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Electrical Data (PDF, 1 page, 126KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_features.pdf\" target=\"_blank\"\u003eAshland SWHD150 Features (PDF, 1 page, 231KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_performance_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Performance Data (PDF, 1 page, 82KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_technical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Technical Data (PDF, 1 page, 135KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_sewage_spec.pdf\" target=\"_blank\"\u003eAshland SWHD150 Catalog Sheet (PDF, 2 pages, 491KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_dimensional_data.pdf\" target=\"_blank\"\u003e Ashland SWHD150 Dimensional Data (PDF, 1 page, 203KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swh50100150200_and_swhd100150200_series_sewage_operating_manual.pdf\" target=\"_blank\"\u003e Ashland DWH50, SWH100, SWG150, SWH200, SWHD100, SWHD150 \u0026amp; SWHD200 Operation, Performance Specifications and Parts Manual (PDF, 51 pages, 2.73MB)\u003c\/a\u003e\u003cbr\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Ashland Pump","offers":[{"title":"Default Title","offer_id":43915835310173,"sku":"SWHD150M3-20","price":1788.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/VSCM0165TTS1ANB0.jpg?v=1766452931"},{"product_id":"swhd150m4-20-ashland-1-5hp-dual-seal-sewage-pump-460vac-3-phase","title":"SWHD150M4-20 Ashland 1.5HP Dual Seal Sewage Pump, 460VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty cast iron construction\u003c\/li\u003e\n\u003cli\u003eOil-filled continuous duty rated PSC\/Induction motor\u003c\/li\u003e\n\u003cli\u003e9 Vane vortex cast iron impeller\u003c\/li\u003e\n\u003cli\u003e2ï¿½ solids handling\u003c\/li\u003e\n\u003cli\u003e2ï¿½ NPT Flanged Discharge\u003c\/li\u003e\n\u003cli\u003eMechanical Carbon Ceramic Seal\u003c\/li\u003e\n\u003cli\u003e20ï¿½ Cord\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eAshland Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSWHD150M4-20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003e460VAC 60Hz 3 Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNEMA Start Code\u003c\/th\u003e\n\u003cth\u003eP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003cth\u003e3.8 Amps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Power Size\u003c\/th\u003e\n\u003cth\u003e16AWG\/4C \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Type\u003c\/th\u003e\n\u003cth\u003eSOW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord O.D.\u003c\/th\u003e\n\u003cth\u003e0.46\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDischarge Size\u003c\/th\u003e\n\u003cth\u003e2\" NPT Flanged\u003cbr\u003e3ï¿½ NPT Optional\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller Type\u003c\/th\u003e\n\u003cth\u003e9-Vane Vortex\u003cbr\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003cth\u003e20'\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolids Handling\u003c\/th\u003e\n\u003cth\u003e2\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Liquid Temperature\u003c\/th\u003e\n\u003cth\u003e104ï¿½F - Intermittent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceptable pH Range\u003c\/th\u003e\n\u003cth\u003e6 - 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Housing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCasing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft\u003c\/th\u003e\n\u003cth\u003eSS416\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003cth\u003eSST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-Rings\u003c\/th\u003e\n\u003cth\u003eNBR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Seal\u003c\/th\u003e\n\u003cth\u003eDual Mechanical\u003cbr\u003eCarbon Ceramic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Type\u003c\/th\u003e\n\u003cth\u003ePSC (Single Phase)\u003cbr\u003eInduction (3 Phase)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGen Insulation Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStator Winding Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Stator Temperature\u003c\/th\u003e\n\u003cth\u003e130ï¿½C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003e+\/-10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Protection\u003c\/th\u003e\n\u003cth\u003eThermally Protected\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService Factor\u003c\/th\u003e\n\u003cth\u003e1.00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SWHD150_Dimensions.webp\" alt=\"SWHD150 Pump Dimensions\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003ePerformance Curve\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SSHD150_Performance.webp\" alt=\"SWHD150 Performance Curve Graph\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_electrical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Electrical Data (PDF, 1 page, 126KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_features.pdf\" target=\"_blank\"\u003eAshland SWHD150 Features (PDF, 1 page, 231KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_performance_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Performance Data (PDF, 1 page, 82KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_technical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Technical Data (PDF, 1 page, 135KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_sewage_spec.pdf\" target=\"_blank\"\u003eAshland SWHD150 Catalog Sheet (PDF, 2 pages, 491KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_dimensional_data.pdf\" target=\"_blank\"\u003e Ashland SWHD150 Dimensional Data (PDF, 1 page, 203KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swh50100150200_and_swhd100150200_series_sewage_operating_manual.pdf\" target=\"_blank\"\u003e Ashland DWH50, SWH100, SWG150, SWH200, SWHD100, SWHD150 \u0026amp; SWHD200 Operation, Performance Specifications and Parts Manual (PDF, 51 pages, 2.73MB)\u003c\/a\u003e\u003cbr\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Ashland Pump","offers":[{"title":"Default Title","offer_id":43915835342941,"sku":"SWHD150M4-20","price":1788.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/EKEBMP85TTS1ANB0.jpg?v=1766452932"},{"product_id":"swhd150m5-20-ashland-1-5hp-dual-seal-sewage-pump-208vac-single-phase","title":"SWHD150M5-20 Ashland 1.5HP Dual Seal Sewage Pump, 208VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty cast iron construction\u003c\/li\u003e\n\u003cli\u003eOil-filled continuous duty rated PSC\/Induction motor\u003c\/li\u003e\n\u003cli\u003e9 Vane vortex cast iron impeller\u003c\/li\u003e\n\u003cli\u003e2ï¿½ solids handling\u003c\/li\u003e\n\u003cli\u003e2ï¿½ NPT Flanged Discharge\u003c\/li\u003e\n\u003cli\u003eMechanical Carbon Ceramic Seal\u003c\/li\u003e\n\u003cli\u003e20ï¿½ Cord\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eAshland Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSWHD150M5-20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003e208VAC 60Hz Single Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNEMA Start Code\u003c\/th\u003e\n\u003cth\u003eP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003cth\u003e15.0 Amps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Power Size\u003c\/th\u003e\n\u003cth\u003e14AWG\/3C \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Type\u003c\/th\u003e\n\u003cth\u003eSOW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord O.D.\u003c\/th\u003e\n\u003cth\u003e0.58\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDischarge Size\u003c\/th\u003e\n\u003cth\u003e2\" NPT Flanged\u003cbr\u003e3ï¿½ NPT Optional\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller Type\u003c\/th\u003e\n\u003cth\u003e9-Vane Vortex\u003cbr\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003cth\u003e20'\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolids Handling\u003c\/th\u003e\n\u003cth\u003e2\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Liquid Temperature\u003c\/th\u003e\n\u003cth\u003e104ï¿½F - Intermittent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceptable pH Range\u003c\/th\u003e\n\u003cth\u003e6 - 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Housing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCasing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft\u003c\/th\u003e\n\u003cth\u003eSS416\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003cth\u003eSST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-Rings\u003c\/th\u003e\n\u003cth\u003eNBR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Seal\u003c\/th\u003e\n\u003cth\u003eDual Mechanical\u003cbr\u003eCarbon Ceramic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Type\u003c\/th\u003e\n\u003cth\u003ePSC (Single Phase)\u003cbr\u003eInduction (3 Phase)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGen Insulation Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStator Winding Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Stator Temperature\u003c\/th\u003e\n\u003cth\u003e130ï¿½C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003e+\/-10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Protection\u003c\/th\u003e\n\u003cth\u003eThermally Protected\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService Factor\u003c\/th\u003e\n\u003cth\u003e1.00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SWHD150_Dimensions.webp\" alt=\"SWHD150 Pump Dimensions\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003ePerformance Curve\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SSHD150_Performance.webp\" alt=\"SWHD150 Performance Curve Graph\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_electrical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Electrical Data (PDF, 1 page, 126KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_features.pdf\" target=\"_blank\"\u003eAshland SWHD150 Features (PDF, 1 page, 231KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_performance_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Performance Data (PDF, 1 page, 82KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_technical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Technical Data (PDF, 1 page, 135KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_sewage_spec.pdf\" target=\"_blank\"\u003eAshland SWHD150 Catalog Sheet (PDF, 2 pages, 491KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_dimensional_data.pdf\" target=\"_blank\"\u003e Ashland SWHD150 Dimensional Data (PDF, 1 page, 203KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swh50100150200_and_swhd100150200_series_sewage_operating_manual.pdf\" target=\"_blank\"\u003e Ashland DWH50, SWH100, SWG150, SWH200, SWHD100, SWHD150 \u0026amp; SWHD200 Operation, Performance Specifications and Parts Manual (PDF, 51 pages, 2.73MB)\u003c\/a\u003e\u003cbr\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Ashland Pump","offers":[{"title":"Default Title","offer_id":43915835375709,"sku":"SWHD150M5-20","price":1788.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TURLCIB5TTS1ANB0.jpg?v=1766452933"},{"product_id":"swhd150m6-20-ashland-1-5hp-dual-seal-sewage-pump-208vac-3-phase","title":"SWHD150M6-20 Ashland 1.5HP Dual Seal Sewage Pump, 208VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty cast iron construction\u003c\/li\u003e\n\u003cli\u003eOil-filled continuous duty rated PSC\/Induction motor\u003c\/li\u003e\n\u003cli\u003e9 Vane vortex cast iron impeller\u003c\/li\u003e\n\u003cli\u003e2ï¿½ solids handling\u003c\/li\u003e\n\u003cli\u003e2ï¿½ NPT Flanged Discharge\u003c\/li\u003e\n\u003cli\u003eMechanical Carbon Ceramic Seal\u003c\/li\u003e\n\u003cli\u003e20ï¿½ Cord\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003cth\u003eAshland Pump\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eSWHD150M6-20\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003e208VAC 60Hz 3 Phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNEMA Start Code\u003c\/th\u003e\n\u003cth\u003eP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003cth\u003e7.8 Amps\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Power Size\u003c\/th\u003e\n\u003cth\u003e16AWG\/4C \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord Type\u003c\/th\u003e\n\u003cth\u003eSOW\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCord O.D.\u003c\/th\u003e\n\u003cth\u003e0.46\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDischarge Size\u003c\/th\u003e\n\u003cth\u003e2\" NPT Flanged\u003cbr\u003e3ï¿½ NPT Optional\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller Type\u003c\/th\u003e\n\u003cth\u003e9-Vane Vortex\u003cbr\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCable Length\u003c\/th\u003e\n\u003cth\u003e20'\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSolids Handling\u003c\/th\u003e\n\u003cth\u003e2\"\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Liquid Temperature\u003c\/th\u003e\n\u003cth\u003e104ï¿½F - Intermittent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceptable pH Range\u003c\/th\u003e\n\u003cth\u003e6 - 8\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Housing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCasing\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpeller\u003c\/th\u003e\n\u003cth\u003eCast Iron\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft\u003c\/th\u003e\n\u003cth\u003eSS416\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware\u003c\/th\u003e\n\u003cth\u003eSST\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-Rings\u003c\/th\u003e\n\u003cth\u003eNBR\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Seal\u003c\/th\u003e\n\u003cth\u003eDual Mechanical\u003cbr\u003eCarbon Ceramic\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower Bearing\u003c\/th\u003e\n\u003cth\u003e6203\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM\u003c\/th\u003e\n\u003cth\u003e3450 RPM\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Type\u003c\/th\u003e\n\u003cth\u003ePSC (Single Phase)\u003cbr\u003eInduction (3 Phase)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGen Insulation Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStator Winding Class\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Stator Temperature\u003c\/th\u003e\n\u003cth\u003e130ï¿½C\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Tolerance\u003c\/th\u003e\n\u003cth\u003e+\/-10%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Protection\u003c\/th\u003e\n\u003cth\u003eThermally Protected\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e1.5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService Factor\u003c\/th\u003e\n\u003cth\u003e1.00\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SWHD150_Dimensions.webp\" alt=\"SWHD150 Pump Dimensions\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003ePerformance Curve\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SSHD150_Performance.webp\" alt=\"SWHD150 Performance Curve Graph\" style=\"width:80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_electrical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Electrical Data (PDF, 1 page, 126KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_features.pdf\" target=\"_blank\"\u003eAshland SWHD150 Features (PDF, 1 page, 231KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_performance_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Performance Data (PDF, 1 page, 82KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_technical_data.pdf\" target=\"_blank\"\u003eAshland SWHD150 Technical Data (PDF, 1 page, 135KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_sewage_spec.pdf\" target=\"_blank\"\u003eAshland SWHD150 Catalog Sheet (PDF, 2 pages, 491KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swhd150_dimensional_data.pdf\" target=\"_blank\"\u003e Ashland SWHD150 Dimensional Data (PDF, 1 page, 203KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/swh50100150200_and_swhd100150200_series_sewage_operating_manual.pdf\" target=\"_blank\"\u003e Ashland DWH50, SWH100, SWG150, SWH200, SWHD100, SWHD150 \u0026amp; SWHD200 Operation, Performance Specifications and Parts Manual (PDF, 51 pages, 2.73MB)\u003c\/a\u003e\u003cbr\u003e\r\n\r\n\r\n\r\n\r\n\r\n\r\n \u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Ashland Pump","offers":[{"title":"Default Title","offer_id":43915835408477,"sku":"SWHD150M6-20","price":1788.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/SGEC2BE5TTS1ANB0.jpg?v=1766452933"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/RPDLVSP4TTS1ANB0.jpg?v=1766431006","url":"https:\/\/witmermotor.com\/collections\/swhd150-1-5hp-dual-seal.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}