{"title":"Marathon VFDs \u0026 Soft Starts","description":"","products":[{"product_id":"174662-00-leeson-sm4-fv-vfd-3ph-208-240v-input","title":"174662.00 Leeson SM4 FV VFD 3Ph 208-240V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915300405341,"sku":"174662.00","price":1996.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3EQM8OK81SFL2890.jpg?v=1766444148"},{"product_id":"174653-00-leeson-sm4-fv-vfd-1ph-115-230v-input","title":"174653.00 Leeson SM4 FV VFD 1Ph 115\/230V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915300995165,"sku":"174653.00","price":731.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OUR1C1OUJRFL2890.jpg?v=1766444156"},{"product_id":"174654-00-leeson-sm4-fv-vfd-1ph-115-230v-input","title":"174654.00 Leeson SM4 FV VFD 1Ph 115\/230V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915305582685,"sku":"174654.00","price":898.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6HQE134EURFL2890.jpg?v=1766444233"},{"product_id":"174603-00-leeson-sm2-flux-vector-vfd-1ph-115-230v","title":"174603.00 Leeson SM2 Flux Vector VFD 1Ph 115\/230V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915401953373,"sku":"174603.00","price":432.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/19C5DS7F035RON50.jpg?v=1766445679"},{"product_id":"174605-00-leeson-sm2-flux-vector-vfd-1ph-115-230v","title":"174605.00 Leeson SM2 Flux Vector VFD 1Ph 115\/230V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915401986141,"sku":"174605.00","price":515.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PM4J8BBF035RON50.jpg?v=1766445678"},{"product_id":"174604-00-leeson-sm2-flux-vector-vfd-single-phase-115-230vac-input","title":"174604.00 Marathon SM2 Flux Vector VFD, Single Phase 115\/230VAC Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402018909,"sku":"174604.00","price":461.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LU2UII8F035RON50.jpg?v=1766445679"},{"product_id":"174606-00-leeson-sm2-flux-vector-vfd-1-3ph-208-240","title":"174606.00 Leeson SM2 Flux Vector VFD 1\/3Ph 208-240","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402051677,"sku":"174606.00","price":409.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/D1TEE1CF035RON50.jpg?v=1766445678"},{"product_id":"174607-00-leeson-sm2-flux-vector-vfd-1-3ph-208-240","title":"174607.00 Leeson SM2 Flux Vector VFD 1\/3Ph 208-240","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402084445,"sku":"174607.00","price":427.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HH49KNCF035RON50.jpg?v=1766445680"},{"product_id":"174608-00-leeson-sm2-flux-vector-vfd-1-3ph-208-240","title":"174608.00 Leeson SM2 Flux Vector VFD 1\/3Ph 208-240","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402117213,"sku":"174608.00","price":451.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LCA0QDDF035RON50.jpg?v=1766445681"},{"product_id":"174609-00-leeson-sm2-flux-vector-vfd-1-3ph-208-240","title":"174609.00 Leeson SM2 Flux Vector VFD 1\/3Ph 208-240","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402182749,"sku":"174609.00","price":504.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PIIK1FEF035RON50.jpg?v=1766445682"},{"product_id":"174616-00-leeson-sm2-flux-vector-vfd-3ph-200-240v","title":"174616.00 Leeson SM2 Flux Vector VFD 3Ph 200-240V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402149981,"sku":"174616.00","price":1038.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5DB8M1LF035RON50.jpg?v=1766445683"},{"product_id":"174617-00-leeson-sm2-flux-vector-vfd-3ph-200-240v","title":"174617.00 Leeson SM2 Flux Vector VFD 3Ph 200-240V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402215517,"sku":"174617.00","price":1283.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P221SNLF035RON50.jpg?v=1766445683"},{"product_id":"174618-00-leeson-sm2-flux-vector-vfd-3ph-200-240v","title":"174618.00 Leeson SM2 Flux Vector VFD 3Ph 200-240V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402248285,"sku":"174618.00","price":2069.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/D2SV1EMF035RON50.jpg?v=1766445683"},{"product_id":"174619-00-leeson-sm2-flux-vector-vfd-3ph-200-240v","title":"174619.00 Leeson SM2 Flux Vector VFD 3Ph 200-240V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402281053,"sku":"174619.00","price":2542.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HJ2H9FNF035RON50.jpg?v=1766445685"},{"product_id":"174621-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174621.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402346589,"sku":"174621.00","price":533.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/554LL0TF035RON50.jpg?v=1766445686"},{"product_id":"174622-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174622.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402379357,"sku":"174622.00","price":576.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P5PARMTF035RON50.jpg?v=1766445685"},{"product_id":"174623-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174623.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402412125,"sku":"174623.00","price":616.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TK5E1DUF035RON50.jpg?v=1766445687"},{"product_id":"174624-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174624.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402444893,"sku":"174624.00","price":722.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HLU39EVF035RON50.jpg?v=1766445686"},{"product_id":"174625-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174625.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402477661,"sku":"174625.00","price":818.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/50NVE40G035RON50.jpg?v=1766445688"},{"product_id":"174626-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174626.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402510429,"sku":"174626.00","price":1033.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P6Q6RL5G035RON50.jpg?v=1766445689"},{"product_id":"174627-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174627.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402543197,"sku":"174627.00","price":1283.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T8MV3N6G035RON50.jpg?v=1766445689"},{"product_id":"174628-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174628.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402575965,"sku":"174628.00","price":2078.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HUGOBO7G035RON50.jpg?v=1766445690"},{"product_id":"174629-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174629.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402608733,"sku":"174629.00","price":2547.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LPMFHE8G035RON50.jpg?v=1766445691"},{"product_id":"174630-00-leeson-sm2-flux-vector-vfd-3ph-400-480v","title":"174630.00 Leeson SM2 Flux Vector VFD 3Ph 400-480V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402641501,"sku":"174630.00","price":3025.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PKS6N49G035RON50.jpg?v=1766445692"},{"product_id":"174631-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174631.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402674269,"sku":"174631.00","price":610.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TQ4RU5AG035RON50.jpg?v=1766445694"},{"product_id":"174632-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174632.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402707037,"sku":"174632.00","price":683.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HUGPN9DG035RON50.jpg?v=1766445692"},{"product_id":"174633-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174633.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402739805,"sku":"174633.00","price":787.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/L3QMTVDG035RON50.jpg?v=1766445694"},{"product_id":"174634-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174634.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402772573,"sku":"174634.00","price":890.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9PGF3MEG035RON50.jpg?v=1766445694"},{"product_id":"174635-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174635.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402805341,"sku":"174635.00","price":1116.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T482BNFG035RON50.jpg?v=1766445696"},{"product_id":"174636-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174636.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402838109,"sku":"174636.00","price":1377.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1VI2HDGG035RON50.jpg?v=1766445695"},{"product_id":"174637-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174637.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402870877,"sku":"174637.00","price":2285.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5464DSJG035RON50.jpg?v=1766445697"},{"product_id":"174639-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174639.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402903645,"sku":"174639.00","price":3087.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/DRG9QJLG035RON50.jpg?v=1766445698"},{"product_id":"174638-00-leeson-sm2-flux-vector-vfd-3ph-480-590v","title":"174638.00 Leeson SM2 Flux Vector VFD 3Ph 480-590V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402936413,"sku":"174638.00","price":2803.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PQRJKTKG035RON50.jpg?v=1766445697"},{"product_id":"174651-00-leeson-sm2-flux-vector-vfd-1ph-115-230v","title":"174651.00 Leeson SM2 Flux Vector VFD 1Ph 115\/230V","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\u003cp\u003eWith its power range up to 25 HP, its flexibility and low price, the SM2 Flux Vector Series inverters excel in applications where inverter technology was once considered too costly.  Applications would include packaging machinery, food processing, machinery, material handling\/conveying systems and HVAC systems.  They carry four modes of operation ï¿½ V\/Hz, Enhanced V\/Hz, Vector Speed and Torque.\u003c\/p\u003e\u003cb\u003eFeatures include:\u003c\/b\u003e\r\nï¿½ Easy set-up operation\r\nï¿½ 4-digit LED display\r\nï¿½ 4- acceleration profiles\r\nï¿½ 0-500 Hz ï¿½ Output frequency, 1000 Hz Optional\r\nï¿½ Eight preset speeds\r\nï¿½ Process control: PID Modes ï¿½ Direct or Reverse Acting\r\nï¿½ Forward\/Reverse\r\nï¿½ Open Loop Flux Vector (Speed or Torque)\r\nï¿½ NEMA 1 ï¿½ IP21 Enclosure Protection\r\nï¿½ Speed commands ï¿½ keypad, jog or floating point control\r\nï¿½ Two independent accel and decal ramps\r\nï¿½ Easy to use keypad \u0026amp; display 6-button interface\r\nï¿½ Voltage monitoring\r\nï¿½ Multiple Braking Functions\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands:keypad, jog, floating point control\r\nï¿½ Voltage: Scalable 0-10 VDC\r\nï¿½ Current: Scalable 4-20 mA, potentiometer,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage\/Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) Motor current (A), motor torque (%), power (kW) Energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback\r\n(user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal\r\ncontinuity, keypad status\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe), GOST (Russia\/Ukraine) C-Tick (Australia\/New Zealand)\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915402969181,"sku":"174651.00","price":638.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HBO30AMG035RON50.jpg?v=1766445699"},{"product_id":"174652-00-leeson-sm4-fv-vfd-1ph-115-230v-input","title":"174652.00 Leeson SM4 FV VFD 1Ph 115\/230V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403001949,"sku":"174652.00","price":648.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/21FS50NG035RON50.jpg?v=1766445699"},{"product_id":"174655-00-leeson-sm4-fv-vfd-1-3ph-208-240v-input","title":"174655.00 Leeson SM4 FV VFD 1\/3Ph 208-240V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403034717,"sku":"174655.00","price":576.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/0I5MN7TG035RON50.jpg?v=1766445700"},{"product_id":"174656-00-leeson-sm4-fv-vfd-1-3ph-208-240v-input","title":"174656.00 Leeson SM4 FV VFD 1\/3Ph 208-240V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403067485,"sku":"174656.00","price":622.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/ELLKIM0H035RON50.jpg?v=1766445701"},{"product_id":"174657-00-leeson-sm4-fv-vfd-1-3ph-208-240v-input","title":"174657.00 Leeson SM4 FV VFD 1\/3Ph 208-240V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403100253,"sku":"174657.00","price":726.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/C5TEOC1H035RON50.jpg?v=1766445701"},{"product_id":"174658-00-leeson-sm4-fv-vfd-1-3ph-208-240v-input","title":"174658.00 Leeson SM4 FV VFD 1\/3Ph 208-240V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403133021,"sku":"174658.00","price":787.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Q5I4U22H035RON50.jpg?v=1766445702"},{"product_id":"174659-00-leeson-sm4-fv-vfd-1-3ph-208-240v-input","title":"174659.00 Leeson SM4 FV VFD 1\/3Ph 208-240V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403165789,"sku":"174659.00","price":941.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/8I0E3P2H035RON50.jpg?v=1766445703"},{"product_id":"174660-00-leeson-sm4-fv-vfd-3ph-208-240v-input","title":"174660.00 Leeson SM4 FV VFD 3Ph 208-240V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403231325,"sku":"174660.00","price":1173.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6N9B9F3H035RON50.jpg?v=1766445703"},{"product_id":"174661-00-leeson-sm4-fv-vfd-3ph-208-240v-input","title":"174661.00 Leeson SM4 FV VFD 3Ph 208-240V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403264093,"sku":"174661.00","price":1583.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/48M05U6H035RON50.jpg?v=1766445704"},{"product_id":"174663-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174663.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403296861,"sku":"174663.00","price":799.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/AE263NIH035RON50.jpg?v=1766445704"},{"product_id":"174664-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174664.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403329629,"sku":"174664.00","price":952.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/8KAQAOJH035RON50.jpg?v=1766445706"},{"product_id":"174665-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174665.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403362397,"sku":"174665.00","price":1097.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/64IKGEKH035RON50.jpg?v=1766445706"},{"product_id":"174666-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174666.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403395165,"sku":"174666.00","price":1356.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/4VNBM4LH035RON50.jpg?v=1766445707"},{"product_id":"174667-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174667.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403427933,"sku":"174667.00","price":1727.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/2FV5SQLH035RON50.jpg?v=1766445707"},{"product_id":"174668-00-leeson-sm4-fv-vfd-3ph-480-590v-input","title":"174668.00 Leeson SM4 FV VFD 3Ph 480-590V Input","description":"\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403460701,"sku":"174668.00","price":2566.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/GIF4N9PH035RON50.jpg?v=1766445707"},{"product_id":"174671-00-leeson-sm4-fv-vfd-3ph-400-480v-input","title":"174671.00 Leeson SM4 FV VFD 3Ph 400-480V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403493469,"sku":"174671.00","price":693.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/U6B6TVPH035RON50.jpg?v=1766445709"},{"product_id":"174672-00-leeson-sm4-fv-vfd-3ph-400-480v-input","title":"174672.00 Leeson SM4 FV VFD 3Ph 400-480V Input","description":"Dimensions: 8.0\" H x 6.28\" W x 4.47\" D\r\n\r\n\u003cb\u003eGeneral Specifications:\u003c\/b\u003e\r\n ï¿½ Indoor use only inverter that is designed to be used with vector duty motors\r\n ï¿½ Typical applications would include : packaging machinery, food processing, conveying systems, machinery and HVAC systems\r\n ï¿½ Enclosure: NEMA 4, IP65, -10 to 55ï¿½C, derate per ï¿½C above 40ï¿½C\r\n\r\n\u003cb\u003eStandard Features:\u003c\/b\u003e\r\nEasy Set-up and Operation: Program the Vector control in one of four convenient ways:\r\n ï¿½ From the front of the drive\r\n ï¿½ The optional remote keypad\r\n ï¿½ A PC Using TechLink software (Available free from www.leeson.com)\r\n ï¿½ The innovative EPM programmer\r\n\r\n\u003cb\u003eModes of operation:\u003c\/b\u003e\r\nï¿½ Open Loop Flux Vector (speed or torque)\r\nï¿½ V\/Hz (constant or variable)\r\nï¿½ Enhanced V\/Hz with auto-tuning\r\n\r\n\u003cb\u003eEasy to Use Keypad \u0026amp; Display\u003c\/b\u003e\r\n6-Button Interface:\r\nï¿½ Start\r\nï¿½ Stop\r\nï¿½ Forward\/reverse\r\nï¿½ Scroll up\r\nï¿½ Scroll down\r\nï¿½ Enter\/mode\r\n\r\n\u003cb\u003eVivid Illumination:\u003c\/b\u003e\r\nï¿½ 4 digit LED display\r\nï¿½ Easy to read from a distance\r\nï¿½ Movable decimal point\r\n\r\n\u003cb\u003eAcceleration\/Deceleration Profiles:\u003c\/b\u003e\r\nï¿½ Two independent accel ramps\r\nï¿½ Two independent decel ramps\r\nï¿½ Linear or S-type\r\nï¿½ Auxiliary ramp-to-stop\r\n\r\n\u003cb\u003eOutput Frequency:\u003c\/b\u003e\r\nï¿½ 500 Hz Std., 1000 Hz optional\r\n\r\n\u003cb\u003eSelectable Logic Assertion:\u003c\/b\u003e\r\nï¿½ Positive logic input (PNP current sourcing)\r\nï¿½ Negative logic input (NPN current sinking)\r\n\r\n\u003cb\u003eMultiple Braking Functions\u003c\/b\u003e\r\nï¿½ Loss of follower management\r\nï¿½ Speed commands: keypad, jog, floating point control\r\nï¿½ Voltage: scalable 0-10 VDC,\r\nï¿½ Current: scalable 4-20 mA, potentiometer,\r\nï¿½ 8 Preset speeds\r\nï¿½ Process control: PID modes: direct or reverse acting,\r\nï¿½ PID sleep mode\r\nï¿½ Voltage monitoring\r\nï¿½ Current monitoring\r\nï¿½ Real time monitoring: 8 register fault history, software version drive network ID, DC bus\r\nï¿½ Voltage (V), motor voltage (V), output current (%) motor current (A), motor torque (%), power (kW) energy consumption (kWh), heatsink\r\nï¿½ Temperature (ï¿½C), 0-10 VDC input (user defined), 4-20 mA input (user defined) PID feedback (user defined), analog output (% load, % torque, kW), network speed (baud rate), terminal continuity, keypad status,\r\nï¿½ Elapsed run time (hours), elapsed power on time (hours)\r\nï¿½ Standards: UL (USA), cUL (Canada), CE (Europe),\r\n\r\n\u003cb\u003eLinks:\u003c\/b\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2SM4_Vector_Series_Adjustable_Speed_AC_Motor_Controller.pdf%20\" target=\"_blank\"\u003eLeeson SM2-SM4 Series Flux Vector Installation and Operation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/SM2_-_SM4_Quick_Reference_Guide.pdf%20\" target=\"_blank\"\u003eLeeson SM2\/SM4 Series Quick Start Guide\u003c\/a\u003e","brand":"Marathon Electric","offers":[{"title":"Default Title","offer_id":43915403526237,"sku":"174672.00","price":740.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/SMI03MQH035RON50.jpg?v=1766445709"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/E15G4F62J2T1ANB0.jpg?v=1773946508","url":"https:\/\/witmermotor.com\/collections\/marathon-7.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}