{"title":"IP20, Dynamic Brake, Safety Module","description":"","products":[{"product_id":"cfw500b02p6t4db20y2-weg-2hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B02P6T4DB20Y2 WEG 2HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013313\u003cbr\u003eCFW500B02P6T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e2 (ND\/VT)\u003cbr\u003e2 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e2.6 (ND\/VT)\u003cbr\u003e2.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867095133,"sku":"CFW500B02P6T4DB20Y2","price":512.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/R0FQ2QQPUUS1ANB0.jpg?v=1766453542"},{"product_id":"cfw500b04p3t4db20y2-weg-3hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B04P3T4DB20Y2 WEG 3HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013372\u003cbr\u003eCFW500B04P3T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e4.3 (ND\/VT)\u003cbr\u003e4.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867127901,"sku":"CFW500B04P3T4DB20Y2","price":623.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9IB3PITPUUS1ANB0.jpg?v=1766453543"},{"product_id":"cfw500b06p5t4db20y2-weg-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B06P5T4DB20Y2 WEG 5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013375\u003cbr\u003eCFW500B06P5T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e5 (ND\/VT)\u003cbr\u003e5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e6.5 (ND\/VT)\u003cbr\u003e6.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867160669,"sku":"CFW500B06P5T4DB20Y2","price":729.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/O9TB9LVPUUS1ANB0.jpg?v=1766453544"},{"product_id":"cfw500b10p0b2db20y2-weg-3hp-variable-speed-drive-200-240vac-single-or-3-phase","title":"CFW500B10P0B2DB20Y2 WEG 3HP Variable Speed Drive, 200-240VAC Single or 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013295\u003cbr\u003eCFW500B10P0B2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e10.0 (ND\/VT)\u003cbr\u003e10.0 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867193437,"sku":"CFW500B10P0B2DB20Y2","price":561.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6UGTIR4QUUS1ANB0.jpg?v=1766453545"},{"product_id":"cfw500b10p0t4db20y2-weg-7-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B10P0T4DB20Y2 WEG 7.5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013578\u003cbr\u003eCFW500B10P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e7.5 (ND\/VT)\u003cbr\u003e7.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e10.0 (ND\/VT)\u003cbr\u003e10.0 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867226205,"sku":"CFW500B10P0T4DB20Y2","price":813.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/577O0J6QUUS1ANB0.jpg?v=1766453545"},{"product_id":"cfw500b16p0t2db20y2-weg-5hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500B16P0T2DB20Y2 WEG 5HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15013297\u003cbr\u003eCFW500B16P0T2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e5 (ND\/VT)\u003cbr\u003e5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e16 (ND\/VT)\u003cbr\u003e16 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867324509,"sku":"CFW500B16P0T2DB20Y2","price":593.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/I5UMVCAQUUS1ANB0.jpg?v=1766453546"},{"product_id":"cfw500c14p0t4db20y2-weg-10hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500C14P0T4DB20Y2 WEG 10HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015352\u003cbr\u003eCFW500C14P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e14 (ND\/VT)\u003cbr\u003e14 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e8.3\" x 5.3\"  x 6.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867717725,"sku":"CFW500C14P0T4DB20Y2","price":987.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/794F1MQQUUS1ANB0.jpg?v=1766453555"},{"product_id":"cfw500c16p0t4db20y2-weg-10hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500C16P0T4DB20Y2 WEG 10HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015354\u003cbr\u003eCFW500C16P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e16 (ND\/VT)\u003cbr\u003e16 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e8.3\" x 5.3\" x 6.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867750493,"sku":"CFW500C16P0T4DB20Y2","price":1101.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6FD5IOSQUUS1ANB0.jpg?v=1766453556"},{"product_id":"cfw500d24p0t4db20y2-weg-15hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500D24P0T4DB20Y2 WEG 15HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015575\u003cbr\u003eCFW500D24P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e15 (ND\/VT)\u003cbr\u003e15 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e24 (ND\/VT)\u003cbr\u003e24 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867783261,"sku":"CFW500D24P0T4DB20Y2","price":1430.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MO7S6B3RUUS1ANB0.jpg?v=1766453556"},{"product_id":"cfw500d28p0t2db20y2-weg-10hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D28P0T2DB20Y2 WEG 10HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015772\u003cbr\u003eCFW500D31P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e25 (ND\/VT)\u003cbr\u003e25 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e31 (ND\/VT)\u003cbr\u003e31 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015488\u003cbr\u003eCFW500D28P0T2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e28 (ND\/VT)\u003cbr\u003e28 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867816029,"sku":"CFW500D28P0T2DB20Y2","price":1157.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5RN1ND5RUUS1ANB0.jpg?v=1766453557"},{"product_id":"cfw500d31p0t4db20y2-weg-25hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500D31P0T4DB20Y2 WEG 25HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015772\u003cbr\u003eCFW500D31P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e25 (ND\/VT)\u003cbr\u003e25 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e31 (ND\/VT)\u003cbr\u003e31 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867848797,"sku":"CFW500D31P0T4DB20Y2","price":1765.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/4JLMAR7RUUS1ANB0.jpg?v=1766453558"},{"product_id":"cfw500d33p0t2db20y2-weg-10hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D33P0T2DB20Y2 WEG 10HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015495\u003cbr\u003eCFW500D33P0T2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e33 (ND\/VT)\u003cbr\u003e33 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867881565,"sku":"CFW500D33P0T2DB20Y2","price":1380.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/J00POI9RUUS1ANB0.jpg?v=1766453558"},{"product_id":"cfw500d47p0t2db20y2-weg-15hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D47P0T2DB20Y2 WEG 15HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015571\u003cbr\u003eCFW500D47P0T2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e15 (ND\/VT)\u003cbr\u003e15 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e47 (ND\/VT)\u003cbr\u003e47 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867914333,"sku":"CFW500D47P0T2DB20Y2","price":1842.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24BL8LBRUUS1ANB0.jpg?v=1766453559"},{"product_id":"cfw500e39p0t4db20y2-weg-30hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500E39P0T4DB20Y2 WEG 30HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015889\u003cbr\u003eCFW500E39P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e30 (ND\/VT)\u003cbr\u003e30 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e39 (ND\/VT)\u003cbr\u003e39 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867947101,"sku":"CFW500E39P0T4DB20Y2","price":2105.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/H6NQMCDRUUS1ANB0.jpg?v=1766453559"},{"product_id":"cfw500e49p0t4db20y2-weg-40hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500E49P0T4DB20Y2 WEG 40HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015891\u003cbr\u003eCFW500E49P0T4DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e40 (ND\/VT)\u003cbr\u003e40 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e49 (ND\/VT)\u003cbr\u003e49 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915867979869,"sku":"CFW500E49P0T4DB20Y2","price":2629.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/0VVP44FRUUS1ANB0.jpg?v=1766453559"},{"product_id":"cfw500e56p0t2db20y2-weg-20hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500E56P0T2DB20Y2 WEG 20HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e15015777\u003cbr\u003eCFW500E56P0T2DB20Y2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e20 (ND\/VT)\u003cbr\u003e20 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e56 (ND\/VT)\u003cbr\u003e56 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Module\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-flyer-50109052-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 2 Pages, 1.09MB)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe style=\"width=100vw;height=calc(100vw\/1.77)\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915868012637,"sku":"CFW500E56P0T2DB20Y2","price":2126.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FN8PIRGRUUS1ANB0.jpg?v=1766453560"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/CNUL1B36VUS1ANB0.jpg?v=1766431015","url":"https:\/\/witmermotor.com\/collections\/ip20-dynamic-brake-safety-module.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}