{"title":"WEG IEC Contactors, 105 Amp (CWM105)","description":"","products":[{"product_id":"cwm105-00-30v18-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V18 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail\u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V18\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e120VAC, 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355054826\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.3 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥ 690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915278843997,"sku":"CWM105-00-30V18","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/EEB6IAM5Q6QUF8U0.jpg?v=1766443831"},{"product_id":"cwm105-00-30v24-contactor-75hp-460v-208-240vcoil","title":"CWM105-00-30V24 Contactor 75HP@460V 208-240VCoil","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V24\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e208-240VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7894171734030\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.3 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915278876765,"sku":"CWM105-00-30V24","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/0QD3KLM5Q6QUF8U0.jpg?v=1766443829"},{"product_id":"cwm105-00-20v18-weg-105-amps-2-pole-contactor-120v","title":"CWM105-00-20V18 WEG 105 AMPS 2 POLE Contactor 120V","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-20V18\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e120VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7894171699803\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387666525,"sku":"CWM105-00-20V18","price":197.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/O0QL7ARL435RON50.jpg?v=1766445443"},{"product_id":"cwm105-00-20v24-weg-2-pole-iec-standard-contactor","title":"CWM105-00-20V24 WEG 2-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-20V24\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e208-230VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7894171699810\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387699293,"sku":"CWM105-00-20V24","price":197.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/M7L0BLRL435RON50.jpg?v=1766445444"},{"product_id":"cwm105-00-30c34-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30C34 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30C34\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e24-28VDC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7894171699346\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.46 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – DC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc: 0.7-0.8 Volt\u003cbr\u003eDrop-out xUc: 0.4-0.6 Volt\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.: 50-60 ms\u003cbr\u003eCoil de-energization – N.O.: 55-60 ms\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed: 6.5 W\u003cbr\u003eInrush: 340 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387732061,"sku":"CWM105-00-30C34","price":331.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/K4H5GBSL435RON50.jpg?v=1766445446"},{"product_id":"cwm105-00-30c40-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30C40 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30C40\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e110-130VDC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355211571\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.46 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – DC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc: 0.7-0.8 Volt\u003cbr\u003eDrop-out xUc: 0.4-0.6 Volt\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.: 50-60 ms\u003cbr\u003eCoil de-energization – N.O.: 55-60 ms\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed: 6.5 W\u003cbr\u003eInrush: 340 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387764829,"sku":"CWM105-00-30C40","price":331.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/I2J7KR0M435RON50.jpg?v=1766445447"},{"product_id":"cwm105-00-30v04-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V04 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V04\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e24VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355066195\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.24 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387797597,"sku":"CWM105-00-30V04","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/GUJLPH1M435RON50.jpg?v=1766445447"},{"product_id":"cwm105-00-30v10-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V10 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V10\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e48VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355066201\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.24 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387830365,"sku":"CWM105-00-30V10","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/UV32V72M435RON50.jpg?v=1766445447"},{"product_id":"cwm105-00-30v37-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V37 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V37\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e277VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355066225\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.24 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387863133,"sku":"CWM105-00-30V37","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/S10R793M435RON50.jpg?v=1766445448"},{"product_id":"cwm105-00-30v47-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V47 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V47\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e480VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355054932\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.24 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387895901,"sku":"CWM105-00-30V47","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Q8V5DV3M435RON50.jpg?v=1766445449"},{"product_id":"cwm105-00-30v56-weg-3-pole-iec-standard-contactor","title":"CWM105-00-30V56 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-00-30V56\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eN\/A\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e500VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355066232\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.24 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387928669,"sku":"CWM105-00-30V56","price":241.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OFUGIL4M435RON50.jpg?v=1766445451"},{"product_id":"cwm105-11-30v18-weg-3-pole-iec-standard-contactor","title":"CWM105-11-30V18 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-11-30V18\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Normally Open\u003cbr\u003e1 Normally Closed\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e120VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355021378\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.30 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387961437,"sku":"CWM105-11-30V18","price":253.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/4DFBT16M435RON50.jpg?v=1766445449"},{"product_id":"cwm105-11-30v24-weg-3-pole-iec-standard-contactor","title":"CWM105-11-30V24 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-11-30V24\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Normally Open\u003cbr\u003e1 Normally Closed\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e208-240VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7894171792481\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.30 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915387994205,"sku":"CWM105-11-30V24","price":253.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/IBIJ537M435RON50.jpg?v=1766445449"},{"product_id":"cwm105-11-30v47-weg-3-pole-iec-standard-contactor","title":"CWM105-11-30V47 WEG 3-Pole IEC Standard Contactor","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003cweg contactors\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\u003ch3\u003eDescription :\u003c\/h3\u003e\r\u003cbr\u003e\u003cp\u003eThe CWM Series IEC Contactor was designed as a general purpose contactor taking into consideration the heavy demands and need for high reliability in modern industry. They are rated for inductive loads up to 800 AMPS @ 460V. CWM Contactors are compact in frame size allowing for optimization of valuable internal space within electrical enclosures. Reducing inventory is a “Snap” away with the CWM Series’ common accessories. \u003c\/p\u003e\r\u003cbr\u003e\u003ch3\u003eStandard Features :\u003c\/h3\u003e\r\u003cbr\u003e\u003cul\u003e\r\u003cbr\u003e\t\u003cli\u003ePanel mountable or 35mm DIN Rail \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFront and Side Mounting Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eFinger-Touch IP20 Protection \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eWide Coil Voltage Protection AC or DC \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMirror Contacts for “Safety-Related” Applications \u003c\/li\u003e\r\u003cbr\u003e\t\u003cli\u003eMechanically linked Auxiliary Contacts \u003c\/li\u003e\r\u003cbr\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\r\u003cbr\u003e\u003ch3\u003eOverview :\u003c\/h3\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBrand\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eWEG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number(s)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105-11-30V47\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eType\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCWM105\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAuxiliary Contacts\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Normally Open\u003cbr\u003e1 Normally Closed\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCurrent Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e105 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e480VAC 60Hz\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Poles\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-25 to +55°C\u003cbr\u003e-13 to +131°F\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminals\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAllen Head\u003cbr\u003e5\/32” (4mm) Drive Size\u003cbr\u003e44.3-57.5 lb-in (5-6.5 Nm)\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTerminal Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eTop: 16-1 AWG\u003cbr\u003eBottom: 10-2 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUPC\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e7890355053201\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eWeight\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3.30 lbs\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eControl Circuit Ratings – AC Coil :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 1000 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage (Ue)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eIEC; VDE 0660: 690 Volts\u003cbr\u003eUL; CSA: 600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003ePick-up xUc:\u003cbr\u003eDrop-out xUc:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Time\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoil Energization – N.O.:\u003cbr\u003eCoil de-energization – N.O.: \u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCoil Consumption\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eSealed:\u003cbr\u003eInrush:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eThermal Power Dissipation\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e60Hz:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Factor\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eClosed:\u003cbr\u003eOpened:\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStranded \/ Solid (UL \/ CSA)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2x12-10 AWG\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard UL\/CSA Ratings :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e600 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eGeneral Purpose Amp Rating (AC-1)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Single Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 HP or 100 Amps @ 115VAC\u003cbr\u003e20 HP or 88 Amps @ 230VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, Full Voltage 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30 HP or 92 Amps @ 200VAC\u003cbr\u003e40 HP or 104 Amps @ 230VAC\u003cbr\u003e75 HP or 96 Amps @ 460VAC\u003cbr\u003e75 HP or 77 Amps @ 575VAC\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Rating\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e10 kA @ 600V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\n\u003cbr\u003e\r\u003cbr\u003e\t\u003ch3\u003eStandard IEC Ratings (IEC EN 60947) :\u003c\/h3\u003e\r\u003cbr\u003e\t\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1000 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Thermal Current Ith\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e140 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eRated Operational Power, Three Phase, AC-3, 50\/60Hz\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e30kW or 105 Amps @ 220-240V\u003cbr\u003e55kW or 105 Amps @ 380-400V\u003cbr\u003e55kW or 105 Amps @ 415-440V\u003cbr\u003e65kW or 85 Amps @ 500V\u003cbr\u003e65kW or 80 Amps @ 660-690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eMaximum Switch Rate\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 1,200 ops\/hr\u003cbr\u003eAC-3: 600 ops\/hr\u003cbr\u003eNo Load: 5,000 ops\/hr\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eAC-4 (200,000 Operations; 50\/60Hz)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12.5kW\/17HP @ 220-230V\u003cbr\u003e22kW\/30HP @ 380-400V\u003cbr\u003e30kW\/40HP @ 415-440V\u003cbr\u003e30kW\/40HP @ 500V\u003cbr\u003e33kW\/45HP @ 660-690V\u003cbr\u003e 50 Amps @ ≥  690V\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eBreaking Capacity\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eUe=400V: 1050 Amps\u003cbr\u003eUe=500V: 1050 Amps\u003cbr\u003eUe=690V: 950 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eImpedance Per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e0.76 mW\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePower Dissipation per Pole\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eAC-1: 14.89 W\u003cbr\u003eAC-3: 8.37 W\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Time Current Icw\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e1 Second: 3,300 Amps\u003cbr\u003e5 Seconds: 1,485 Amps\u003cbr\u003e10 Seconds: 1,050 Amps\u003cbr\u003e30 Seconds: 600Amps\u003cbr\u003e1 Minute: 430 Amps\u003cbr\u003e3 Minutes: 250 Amps\u003cbr\u003eRec. Time: 10 minutes\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eShort Circuit Coordination\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCoordination Type “1”: 250 gL\/gG\u003cbr\u003eCoordination Type “2”: 200 gL\/gG\u003cbr\u003eAcc. To UL\/CSA: 200 J Type\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003e\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/weg\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915388026973,"sku":"CWM105-11-30V47","price":253.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/GIHUAP7M435RON50.jpg?v=1766445450"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/0VJ9LEPTC43GAON0.jpg?v=1766431053","url":"https:\/\/witmermotor.com\/collections\/cwm105.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}