{"title":"CV \/ 2CV Series","description":"","products":[{"product_id":"472104011u03-stearns-sinpac-electronic-switch","title":"472104011U03 Stearns SINPAC Electronic Switch","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cp\u003e\u003cb\u003e\r\u003cbr\u003eCV Series for 115 Vac or 115\/230 Vac Dual Voltage Capacitor Start Motors\r\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBasic Operation\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCapacitor start motors require a method to extract speed data from the voltage across the motor start winding. By comparing the start winding RPM-sensitive voltage with the main AC input voltage (which serves as a reference voltage), the switch determines when the start circuit should be energized. The electronic switch interrupts the start circuit current after the motor has accelerated to the cut out speed, and reconnects the start circuit whenever the motor speed has fallen to cut in speed (usually about 50% of synchronous motor speed).\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 1. Electrically Protected:\u003c\/b\u003e Designed to filter out electrical noise, so there is no concern of random switch malfunction.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 2. Reduced Installation Time:\u003c\/b\u003e Easily accessible 1\/4 inch terminals and mounting, reduce the amount of time required to install SINPAC Switches or to change out mechanical switches.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 3. Restart Capability:\u003c\/b\u003e When motor speed drops below 50% of synchronous speed, the start circuit is reconnected to reinitiate starting torque.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 4. Soldered Heat Sink:\u003c\/b\u003e High cycling.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 5. Transient Protection:\u003c\/b\u003e Transient protection tested per IEEE C62.41 – 1991 Category A3.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 6. Universal Design\u003c\/b\u003e 50\/60 Hz operation. Will work on 2, 4 or 6 pole motors of any manufacturer. Reduced inventory.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 7. Line Voltage Compensation:\u003c\/b\u003e No modifications or changes are required for line voltage variations. SINPAC Switches will operate in areas susceptible to brownouts or low voltage due to long wiring runs. It also means there will be less stress on the starting capacitor due to over voltage.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\t\u003cheader class=\"productspecifications-header\"\u003e\r\u003cbr\u003e\t\t\u003ch3\u003eGeneral Information\u003c\/h3\u003e\r\u003cbr\u003e\t\u003c\/header\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTypical Max Motor Horsepower (HP)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e2 HP\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTypical Full Load Motor Nameplate Current Rating (Amps)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e20 Amps @ 115 Volts\u003cbr\u003e20\/10 Amps @ 115\/230 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eSwitch Rating \u0026amp; Permissible Maximum Start Circuit Current (Amps)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e40 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStart Circuit Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e115\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCut Out Voltage (Typical)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e165\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCut In Voltage Typical\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e37\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePackage Style\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e11\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCV-40-165\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePart Number\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eStearns 4-7-21040-11-U02\u003cbr\u003e Leeson 002785.03\u003cbr\u003eStearns Kit 472104011U0K\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\t\u003cheader class=\"productspecifications-header\"\u003e\r\u003cbr\u003e\t\t\u003ch3\u003eAdditional Features\u003c\/h3\u003e\r\u003cbr\u003e\t\u003c\/header\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUL Recognition (E71115) to US and Canadian Standards\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-40°C to 65°C (-40°F to 149°F)\u003cbr\u003eFor Operation between 65°C and 85°C (149°F and 185°F), Consult Factory.\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e115 Vac SINPAC Switch: 90-130 Vac\u003cbr\u003eFor Dual Voltage motor equipped with center-tapped main winding: 90-130 Vac or 180-265 Vac.\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\u003cp\u003e\u003cb\u003eSelection\u003c\/b\u003e\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMotor HP ratings are typical. For an accurate selection procedure, measure start capacitor current during a normal start or at locked rotor and select a SINPAC Switch with higher maximum current  rating than that measured.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e1. Be sure switch series matches motor type.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2. Be sure switch voltage rating matches (start) circuit voltage rating.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e3. Selection can be based on actual measurement of start capacitor current or two times the motor nameplate FLA rating.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e4. Switch current rating must match or exceed the motor start capacitor current requirements. Always select a SINPAC Switch with the next higher current rating for:\r\u003cbr\u003e\u003cbr\u003ea) High cycling applications.\r\u003cbr\u003e\u003cbr\u003eb) Long acceleration time.\r\u003cbr\u003e\u003cbr\u003ec) High ambients: Greater than 55° C.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e5. To assure proper motor operation, the voltage across the start winding must reach the SINPAC Switch cut out reference voltage between 70% to 85% of motors synchronous speed.\r\u003cbr\u003e\u003cbr\u003eCaution: SINPAC Switches are line voltage compensated. Changes in the line voltage will not affect system operation unless an overload condition causes reduced running speed, along with reduced voltage across the start winding.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e6. Higher current switches can be used in place of lower rated switches of the same series.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLine Voltage Compensation Charts\u003c\/b\u003e\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eInduced voltage across the start winding is directly proportional to motor speed and line voltage. All SINPAC Switches use this voltage to switch the start capacitor out of the circuit. Your motor with a SINPAC Switch must generate a voltage that is 20% greater than the switch cut out voltage to assure cut out of the start capacitor. Refer to charts above.\r\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/htmlonly\u003e","brand":"Stearns\/Rexnord Corporation","offers":[{"title":"Default Title","offer_id":43915278712925,"sku":"CV40-165","price":144.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/O79CFVL5Q6QUF8U0.jpg?v=1766443826"},{"product_id":"472105012u03-stearns-sinpac-electronic-switch","title":"472105012U03 Stearns SINPAC Electronic Switch","description":"\u003chtmlonly\u003e\r\u003cbr\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/Genericproduct.css\"\u003e\r\u003cbr\u003e\u003cp\u003e\u003cb\u003e\r\u003cbr\u003eCV Series for 115 Vac or 115\/230 Vac Dual Voltage Capacitor Start Motors\r\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eBasic Operation\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eCapacitor start motors require a method to extract speed data from the voltage across the motor start winding. By comparing the start winding RPM-sensitive voltage with the main AC input voltage (which serves as a reference voltage), the switch determines when the start circuit should be energized. The electronic switch interrupts the start circuit current after the motor has accelerated to the cut out speed, and reconnects the start circuit whenever the motor speed has fallen to cut in speed (usually about 50% of synchronous motor speed).\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 1. Electrically Protected:\u003c\/b\u003e Designed to filter out electrical noise, so there is no concern of random switch malfunction.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 2. Reduced Installation Time:\u003c\/b\u003e Easily accessible 1\/4 inch terminals and mounting, reduce the amount of time required to install SINPAC Switches or to change out mechanical switches.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 3. Restart Capability:\u003c\/b\u003e When motor speed drops below 50% of synchronous speed, the start circuit is reconnected to reinitiate starting torque.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 4. Soldered Heat Sink:\u003c\/b\u003e High cycling.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 5. Transient Protection:\u003c\/b\u003e Transient protection tested per IEEE C62.41 – 1991 Category A3.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 6. Universal Design\u003c\/b\u003e 50\/60 Hz operation. Will work on 2, 4 or 6 pole motors of any manufacturer. Reduced inventory.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e 7. Line Voltage Compensation:\u003c\/b\u003e No modifications or changes are required for line voltage variations. SINPAC Switches will operate in areas susceptible to brownouts or low voltage due to long wiring runs. It also means there will be less stress on the starting capacitor due to over voltage.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"productspecifications\"\u003e\r\u003cbr\u003e\t\u003cheader class=\"productspecifications-header\"\u003e\r\u003cbr\u003e\t\t\u003ch3\u003eGeneral Information\u003c\/h3\u003e\r\u003cbr\u003e\t\u003c\/header\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTypical Max Motor Horsepower (HP)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e3 HP\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eTypical Full Load Motor Nameplate Current Rating (Amps)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e25 Amps @ 115 Volts\u003cbr\u003e25\/12.5 Amps @ 115\/230 Volts\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eSwitch Rating \u0026amp; Permissible Maximum Start Circuit Current (Amps)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e50 Amps\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eStart Circuit Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e115\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCut Out Voltage (Typical)\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e165\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCut In Voltage Typical\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e37\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePackage Style\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e12\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eCatalog Number\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eCV-50-165\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003ePart Number\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003eLeeson 002785.04\u003cbr\u003eStearns 4-7-21050-12-U01\u003cbr\u003e Stearns Sinpak with Gasket 472105012U0K\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\t\u003cheader class=\"productspecifications-header\"\u003e\r\u003cbr\u003e\t\t\u003ch3\u003eAdditional Features\u003c\/h3\u003e\r\u003cbr\u003e\t\u003c\/header\u003e\r\u003cbr\u003e\t\u003ctable\u003e\r\u003cbr\u003e\t\t\u003ctbody\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eUL Recognition (E71115) to US and Canadian Standards\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Temperature\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e-40°C to 65°C (-40°F to 149°F)\u003cbr\u003eFor Operation between 65°C and 85°C (149°F and 185°F), Consult Factory.\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\t\u003ctr\u003e\r\u003cbr\u003e\t\t\t\t\u003cth\u003eOperating Voltage\u003c\/th\u003e\r\u003cbr\u003e\t\t\t\t\u003ctd\u003e115 Vac SINPAC Switch: 90-130 Vac\u003cbr\u003eFor Dual Voltage motor equipped with center-tapped main winding: 90-130 Vac or 180-265 Vac.\u003c\/td\u003e\r\u003cbr\u003e\t\t\t\u003c\/tr\u003e\r\u003cbr\u003e\t\t\u003c\/tbody\u003e\r\u003cbr\u003e\t\u003c\/table\u003e\r\u003cbr\u003e\u003cp\u003e\u003cb\u003eSelection\u003c\/b\u003e\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMotor HP ratings are typical. For an accurate selection procedure, measure start capacitor current during a normal start or at locked rotor and select a SINPAC Switch with higher maximum current  rating than that measured.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e1. Be sure switch series matches motor type.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e2. Be sure switch voltage rating matches (start) circuit voltage rating.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e3. Selection can be based on actual measurement of start capacitor current or two times the motor nameplate FLA rating.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e4. Switch current rating must match or exceed the motor start capacitor current requirements. Always select a SINPAC Switch with the next higher current rating for:\r\u003cbr\u003e\u003cbr\u003ea) High cycling applications.\r\u003cbr\u003e\u003cbr\u003eb) Long acceleration time.\r\u003cbr\u003e\u003cbr\u003ec) High ambients: Greater than 55° C.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e5. To assure proper motor operation, the voltage across the start winding must reach the SINPAC Switch cut out reference voltage between 70% to 85% of motors synchronous speed.\r\u003cbr\u003e\u003cbr\u003eCaution: SINPAC Switches are line voltage compensated. Changes in the line voltage will not affect system operation unless an overload condition causes reduced running speed, along with reduced voltage across the start winding.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e6. Higher current switches can be used in place of lower rated switches of the same series.\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLine Voltage Compensation Charts\u003c\/b\u003e\r\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eInduced voltage across the start winding is directly proportional to motor speed and line voltage. All SINPAC Switches use this voltage to switch the start capacitor out of the circuit. Your motor with a SINPAC Switch must generate a voltage that is 20% greater than the switch cut out voltage to assure cut out of the start capacitor. Refer to charts above.\r\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\r\u003cbr\u003e\u003c\/htmlonly\u003e","brand":"Stearns\/Rexnord Corporation","offers":[{"title":"Default Title","offer_id":43915278745693,"sku":"CV50-165","price":180.98,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/QDSAHAM5Q6QUF8U0.jpg?v=1766443827"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/5S5991UUR8K0FAR0.jpg?v=1766430645","url":"https:\/\/witmermotor.com\/collections\/cv-2cv-series.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}