{"title":"CFW500 G2","description":"","products":[{"product_id":"cfw500b06p5t4db20g2-weg-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B06P5T4DB20G2 WEG 5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B06P5T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e5 (ND\/VT)\u003cbr\u003e5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e6.5 (ND\/VT)\u003cbr\u003e6.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915857625181,"sku":"CFW500B06P5T4DB20G2","price":644.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/G42TQ7BT3VOOJ6T0.jpg?v=1766453376"},{"product_id":"cfw500b16p0t2db20g2-weg-5hp-variable-speed-drive-200-240-vac-3-phase","title":"CFW500B16P0T2DB20G2 WEG, 5HP Variable Speed Drive, 200 - 240 VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915857657949,"sku":"CFW500B16P0T2DB20G2","price":508.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V5CSNSG0VUOOJ6T0.jpg?v=1766453376"},{"product_id":"cfw500a02p6t4nb20g2-weg-1-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500A02P6T4NB20G2 WEG 1.5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A02P6T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e2 (ND\/VT)\u003cbr\u003e2 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e2.6 (ND\/VT)\u003cbr\u003e2.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915857690717,"sku":"CFW500A02P6T4NB20G2","price":392.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PA79JDG1VUOOJ6T0.jpg?v=1766453377"},{"product_id":"cfw500a04p3t4nb20g2-weg-3hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500A04P3T4NB20G2 WEG 3HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A04P3T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e4.3 (ND\/VT)\u003cbr\u003e4.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915857723485,"sku":"CFW500A04P3T4NB20G2","price":482.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/627CIBC3VUOOJ6T0.jpg?v=1766453379"},{"product_id":"cfw500a01p6b2nb20g2-weg-1-3hp-variable-speed-drive-200-240vac-single-3-phase","title":"CFW500A01P6B2NB20G2 WEG 1\/3HP Variable Speed Drive, 200-240VAC Single\/3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A01P6B2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e0.33 (ND\/VT)\u003cbr\u003e0.33 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e1.6 (ND\/VT)\u003cbr\u003e1.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858706525,"sku":"CFW500A01P6B2NB20G2","price":275.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/CTRLI55KSTS1ANB0.jpg?v=1766453394"},{"product_id":"cfw500a02p6b2nb20g2-weg-3-4hp-variable-speed-drive-200-240vac-single-3-phase","title":"CFW500A02P6B2NB20G2 WEG 3\/4HP Variable Speed Drive, 200-240VAC Single\/3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A02P6B2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VACVAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e0.75 (ND\/VT)\u003cbr\u003e0.75 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e2.6 (ND\/VT)\u003cbr\u003e2.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858739293,"sku":"CFW500A02P6B2NB20G2","price":282.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RNKJRBAKSTS1ANB0.jpg?v=1766453394"},{"product_id":"cfw500a04p3b2nb20g2-weg-1-5hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500A04P3B2NB20G2 WEG 1.5HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A04P3B2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e1.5 (ND\/VT)\u003cbr\u003e1.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e4.3 (ND\/VT)\u003cbr\u003e4.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858772061,"sku":"CFW500A04P3B2NB20G2","price":305.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Q0SSNQDKSTS1ANB0.jpg?v=1766453395"},{"product_id":"cfw500b07p3b2db20g2-weg-2hp-variable-speed-drive-200-240vac-single-3-phase","title":"CFW500B07P3B2DB20G2 WEG 2HP Variable Speed Drive, 200-240VAC Single\/3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B07P3B2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e1.5 (ND\/VT)\u003cbr\u003e1.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e7.3 (ND\/VT)\u003cbr\u003e7.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858804829,"sku":"CFW500B07P3B2DB20G2","price":409.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/94O7MKHKSTS1ANB0.jpg?v=1766453396"},{"product_id":"cfw500b10p0b2db20g2-weg-3hp-variable-speed-drive-200-240vac-single-3-phase","title":"CFW500B10P0B2DB20G2 WEG 3HP Variable Speed Drive, 200-240VAC Single\/3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B10P0B2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle or 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e10.0 (ND\/VT)\u003cbr\u003e10.0 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858837597,"sku":"CFW500B10P0B2DB20G2","price":476.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/8EU7KELKSTS1ANB0.jpg?v=1766453396"},{"product_id":"cfw500a01p6s2nb20g2-weg-1-3hp-variable-speed-drive-200-240vac-single-phase","title":"CFW500A01P6S2NB20G2 WEG 1\/3HP Variable Speed Drive, 200-240VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A01P6S2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e0.33 (ND\/VT)\u003cbr\u003e0.33 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e1.6 (ND\/VT)\u003cbr\u003e1.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858870365,"sku":"CFW500A01P6S2NB20G2","price":272.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OOFEH2TKSTS1ANB0.jpg?v=1766453396"},{"product_id":"cfw500a02p6s2nb20g2-weg-3-4hp-variable-speed-drive-200-240vac-single-phase","title":"CFW500A02P6S2NB20G2 WEG 3\/4HP Variable Speed Drive, 200-240VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A02P6S2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e0.75 (ND\/VT)\u003cbr\u003e0.75 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e2.6 (ND\/VT)\u003cbr\u003e2.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858903133,"sku":"CFW500A02P6S2NB20G2","price":279.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/KSBPFS0LSTS1ANB0.jpg?v=1766453396"},{"product_id":"cfw500a04p3s2nb20g2-weg-1-1-2hp-variable-speed-drive-200-240vac-single-phase","title":"CFW500A04P3S2NB20G2 WEG 1 1\/2HP Variable Speed Drive, 200-240VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A04P3S2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e1.5 (ND\/VT)\u003cbr\u003e1.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e4.3 (ND\/VT)\u003cbr\u003e4.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915858935901,"sku":"CFW500A04P3S2NB20G2","price":301.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/GSQ66L3LSTS1ANB0.jpg?v=1766453398"},{"product_id":"cfw500a07p0s2nb20g2-weg-2hp-variable-speed-drive-200-240vac-single-phase","title":"CFW500A07P0S2NB20G2 WEG 2HP Variable Speed Drive, 200-240VAC Single Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A07P0S2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e2 (ND\/VT)\u003cbr\u003e2 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e7.3 (ND\/VT)\u003cbr\u003e7.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859001437,"sku":"CFW500A07P0S2NB20G2","price":382.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/CU96I69LSTS1ANB0.jpg?v=1766453398"},{"product_id":"cfw500a09p6t2nb20g2-weg-3hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500A09P6T2NB20G2 WEG 3HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A09P6T2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e9.6 (ND\/VT)\u003cbr\u003e9.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859034205,"sku":"CFW500A09P6T2NB20G2","price":466.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3TLPTTS03US1ANB0.jpg?v=1766453399"},{"product_id":"cfw500a07p0t2nb20g2-weg-2hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500A07P0T2NB20G2 WEG 2HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A07P0T2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e2 (ND\/VT)\u003cbr\u003e2 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e7.0 (ND\/VT)\u003cbr\u003e7.0 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859066973,"sku":"CFW500A07P0T2NB20G2","price":379.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6GBNF6R03US1ANB0.jpg?v=1766453399"},{"product_id":"cfw500c24p0t2db20g2-weg-7-5hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500C24P0T2DB20G2 WEG 7.5HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500C24P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e7.5 (ND\/VT)\u003cbr\u003e7.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e24 (ND\/VT)\u003cbr\u003e24 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e8.3\" x 5.3\" x 6.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859132509,"sku":"CFW500C24P0T2DB20G2","price":861.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/0IMMPC013US1ANB0.jpg?v=1766453401"},{"product_id":"cfw500d28p0t2db20g2-weg-10hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D28P0T2DB20G2 WEG 10HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500D28P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e28 (ND\/VT)\u003cbr\u003e28 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859165277,"sku":"CFW500D28P0T2DB20G2","price":1073.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/D3P0AF213US1ANB0.jpg?v=1766453401"},{"product_id":"cfw500d47p0t2db20g2-weg-15hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D47P0T2DB20G2 WEG 15HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500D47P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e15 (ND\/VT)\u003cbr\u003e15 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e47 (ND\/VT)\u003cbr\u003e47 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859198045,"sku":"CFW500D47P0T2DB20G2","price":1757.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/AFIGEV613US1ANB0.jpg?v=1766453403"},{"product_id":"cfw500e56p0t2db20g2-weg-25hp-vt-20hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500E56P0T2DB20G2 WEG, 25HP-VT, 20HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500E56P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e20 (ND\/VT)\u003cbr\u003e20 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e56 (ND\/VT)\u003cbr\u003e56 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859230813,"sku":"CFW500E56P0T2DB20G2","price":2041.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/764PU1913US1ANB0.jpg?v=1766453402"},{"product_id":"cfw500f77p0t2db20g2-weg-25hp-vt-20hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500F77P0T2DB20G2 WEG 25HP-VT, 20HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F77P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e25 (ND\/VT)\u003cbr\u003e20 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e77 (ND\/VT)\u003cbr\u003e64 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859263581,"sku":"CFW500F77P0T2DB20G2","price":2506.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/4UCOCPA13US1ANB0.jpg?v=1766453403"},{"product_id":"cfw500f88p0t2db20g2-weg-30hp-vt-25hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500F88P0T2DB20G2 WEG 30HP-VT, 25HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F88P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e30 (ND\/VT)\u003cbr\u003e25 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e88 (ND\/VT)\u003cbr\u003e75 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859296349,"sku":"CFW500F88P0T2DB20G2","price":3140.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1CIHQGC13US1ANB0.jpg?v=1766453405"},{"product_id":"cfw500f0105t2db20g2-weg-40hp-vt-30hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500F0105T2DB20G2 WEG 40HP-VT, 30HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F0105T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e40 (ND\/VT)\u003cbr\u003e30 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e105 (ND\/VT)\u003cbr\u003e88 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859329117,"sku":"CFW500F0105T2DB20G2","price":4258.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/ETKRAJE13US1ANB0.jpg?v=1766453405"},{"product_id":"cfw500a01p0t4nb20g2-weg-1-2hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500A01P0T4NB20G2 WEG 1\/2HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A01P0T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e0.50 (ND\/VT)\u003cbr\u003e0.50 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e1.0 (ND\/VT)\u003cbr\u003e1.0 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\r\n\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859361885,"sku":"CFW500A01P0T4NB20G2","price":351.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BJES8CQ13US1ANB0.jpg?v=1766453404"},{"product_id":"cfw500a01p6t4nb20g2-weg-1hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500A01P6T4NB20G2 WEG 1HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A01P6T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e1 (ND\/VT)\u003cbr\u003e1 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e1.6 (ND\/VT)\u003cbr\u003e1.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859394653,"sku":"CFW500A01P6T4NB20G2","price":364.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/OPI9PES13US1ANB0.jpg?v=1766453405"},{"product_id":"cfw500a06p1t4nb20g2-weg-3hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500A06P1T4NB20G2 WEG 3HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500A06P1T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e6.1 (ND\/VT)\u003cbr\u003e6.1 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.5\" x 3.0\" x 5.9\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859427421,"sku":"CFW500A06P1T4NB20G2","price":593.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5HQ23L123US1ANB0.jpg?v=1766453406"},{"product_id":"cfw500b02p6t4db20g2-weg-1-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B02P6T4DB20G2 WEG 1.5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B02P6T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e2 (ND\/VT)\u003cbr\u003e2 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e2.6 (ND\/VT)\u003cbr\u003e2.6 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859460189,"sku":"CFW500B02P6T4DB20G2","price":427.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/2K1VGC323US1ANB0.jpg?v=1766453407"},{"product_id":"cfw500b04p3t4db20g2-weg-3hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B04P3T4DB20G2 WEG 3HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B04P3T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e3 (ND\/VT)\u003cbr\u003e3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e4.3 (ND\/VT)\u003cbr\u003e4.3 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859492957,"sku":"CFW500B04P3T4DB20G2","price":538.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/VLD4V3523US1ANB0.jpg?v=1766453407"},{"product_id":"cfw500c14p0t4db20g2-weg-10hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500C14P0T4DB20G2 WEG 10HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500C14P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e14 (ND\/VT)\u003cbr\u003e14 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e8.3\" x 5.3\" x 6.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859558493,"sku":"CFW500C14P0T4DB20G2","price":902.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/96KHBLA23US1ANB0.jpg?v=1766453407"},{"product_id":"cfw500b10p0t4db20g2-weg-7-5hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500B10P0T4DB20G2 WEG 7.5HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500B10P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e7.5 (ND\/VT)\u003cbr\u003e7.5 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e7.9\" x 4.0\" x 6.3\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859525725,"sku":"CFW500B10P0T4DB20G2","price":729.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/CP9FTT823US1ANB0.jpg?v=1766453407"},{"product_id":"cfw500d24p0t4db20g2-weg-15hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500D24P0T4DB20G2 WEG 15HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003eVAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003eVAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e (ND\/VT)\u003cbr\u003e (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e (ND\/VT)\u003cbr\u003e (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859624029,"sku":"CFW500D24P0T4DB20G2","price":1346.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEKGF5F23US1ANB0.jpg?v=1766453409"},{"product_id":"cfw500d31p0t4db20g2-weg-20-25hp-variable-speed-drive-380-480vac-3-ph","title":"CFW500D31P0T4DB20G2 WEG 20\/25HP Variable Speed Drive, 380-480VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500D31P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e25 (ND\/VT)\u003cbr\u003e25 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e24 (ND\/VT)\u003cbr\u003e24 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859656797,"sku":"CFW500D31P0T4DB20G2","price":1680.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JST9V7H23US1ANB0.jpg?v=1766453409"},{"product_id":"cfw500e39p0t4db20g2-weg-30hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500E39P0T4DB20G2 WEG 30HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500E39P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e30 (ND\/VT)\u003cbr\u003e30 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e39 (ND\/VT)\u003cbr\u003e39 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859689565,"sku":"CFW500E39P0T4DB20G2","price":2020.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/GU9FDVI23US1ANB0.jpg?v=1766453410"},{"product_id":"cfw500e49p0t4db20g2-weg-40hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500E49P0T4DB20G2 WEG 40HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500E49P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e40 (ND\/VT)\u003cbr\u003e40 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e49 (ND\/VT)\u003cbr\u003e49 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e13.8\" x 8.7\" x 7.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859722333,"sku":"CFW500E49P0T4DB20G2","price":2545.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TQ6MRMK23US1ANB0.jpg?v=1766453410"},{"product_id":"cfw500f77p0t4db20g2-weg-50-60hp-vt-50hp-ct-variable-speed-drive-380-480vac-3ph","title":"CFW500F77P0T4DB20G2 WEG 50\/60HP-VT, 50HP-CT Variable Speed Drive, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F77P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e60 (ND\/VT)\u003cbr\u003e50 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e77 (ND\/VT)\u003cbr\u003e61 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859755101,"sku":"CFW500F77P0T4DB20G2","price":3442.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/QTHIBPM23US1ANB0.jpg?v=1766453411"},{"product_id":"cfw500f88p0t4db20g2-weg-75hp-vt-60hp-ct-variable-speed-drive-380-480vac-3ph","title":"CFW500F88P0T4DB20G2 WEG 75HP-VT, 60HP-CT Variable Speed Drive, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F88P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e75 (ND\/VT)\u003cbr\u003e60 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e88 (ND\/VT)\u003cbr\u003e73 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859787869,"sku":"CFW500F88P0T4DB20G2","price":4409.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NVTNPGO23US1ANB0.jpg?v=1766453411"},{"product_id":"cfw500f0105t4db20g2-weg-75hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500F0105T4DB20G2 WEG 75HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500F0105T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e75 (ND\/VT)\u003cbr\u003e75 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e105 (ND\/VT)\u003cbr\u003e88 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e21.6\" x 11.8\" x 10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859820637,"sku":"CFW500F0105T4DB20G2","price":5375.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/KMB088Q23US1ANB0.jpg?v=1766453412"},{"product_id":"cfw500d33p0t2db20g2-weg-10hp-variable-speed-drive-200-240vac-3-phase","title":"CFW500D33P0T2DB20G2 WEG 10HP Variable Speed Drive, 200-240VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500D33P0T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e33 (ND\/VT)\u003cbr\u003e33 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e12.1\" x 7.1\" x 6.6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.5 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859853405,"sku":"CFW500D33P0T2DB20G2","price":1296.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RLDPJQ343US1ANB0.jpg?v=1766453412"},{"product_id":"cfw500g0145t2nb20g2-weg-50hp-vt-40hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0145T2NB20G2 WEG 50HP-VT, 40HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0145T2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e50 (ND\/VT)\u003cbr\u003e40 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e145 (ND\/VT)\u003cbr\u003e115 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859886173,"sku":"CFW500G0145T2NB20G2","price":5134.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/N8LUPL843US1ANB0.jpg?v=1766453413"},{"product_id":"cfw500g0180t2nb20g2-weg-60hp-vt-50hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0180T2NB20G2 WEG 60HP-VT, 50HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0180T2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e60 (ND\/VT)\u003cbr\u003e50 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e180 (ND\/VT)\u003cbr\u003e145 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859918941,"sku":"CFW500G0180T2NB20G2","price":6191.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3ABFJPB43US1ANB0.jpg?v=1766453413"},{"product_id":"cfw500g0211t2nb20g2-weg-75hp-vt-60hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0211T2NB20G2 WEG 75HP-VT, 60HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0211T2NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e75 (ND\/VT)\u003cbr\u003e60 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e211 (ND\/VT)\u003cbr\u003e180 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859951709,"sku":"CFW500G0211T2NB20G2","price":8154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FNUJE8F43US1ANB0.jpg?v=1766453414"},{"product_id":"cfw500g0145t2db20g2-weg-50hp-vt-40hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0145T2DB20G2 WEG 50HP-VT, 40HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0145T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e50 (ND\/VT)\u003cbr\u003e40 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e145 (ND\/VT)\u003cbr\u003e115 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915859984477,"sku":"CFW500G0145T2DB20G2","price":5493.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RPFR7CI43US1ANB0.jpg?v=1766453414"},{"product_id":"cfw500g0180t2db20g2-weg-60hp-vt-50hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0180T2DB20G2 WEG 60HP-VT, 50HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0180T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e60 (ND\/VT)\u003cbr\u003e50 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e180 (ND\/VT)\u003cbr\u003e145 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860017245,"sku":"CFW500G0180T2DB20G2","price":6622.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/714LT4L43US1ANB0.jpg?v=1766453415"},{"product_id":"cfw500g0211t2db20g2-weg-75hp-vt-60hp-ct-variable-speed-drive-200-240vac-3-ph","title":"CFW500G0211T2DB20G2 WEG 75HP-VT, 60HP-CT Variable Speed Drive, 200-240VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0211T2DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e200-240VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e230VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e75 (ND\/VT)\u003cbr\u003e60 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e211 (ND\/VT)\u003cbr\u003e180 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860050013,"sku":"CFW500G0211T2DB20G2","price":8724.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JTLHHIN43US1ANB0.jpg?v=1766453416"},{"product_id":"cfw500c16p0t4db20g2-weg-10hp-variable-speed-drive-380-480vac-3-phase","title":"CFW500C16P0T4DB20G2 WEG 10HP Variable Speed Drive, 380-480VAC 3 Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500C16P0T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e10 (ND\/VT)\u003cbr\u003e10 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e16 (ND\/VT)\u003cbr\u003e16 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e8.3\" x 5.3\" x 6.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860082781,"sku":"CFW500C16P0T4DB20G2","price":1017.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V3POT3T43US1ANB0.jpg?v=1766453417"},{"product_id":"cfw500g0142t4nb20g2-weg-100-125hp-vt-100hp-ct-variable-speed-380-480vac-3ph","title":"CFW500G0142T4NB20G2 WEG 100\/125HP-VT, 100HP-CT, Variable Speed, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0142T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e125 (ND\/VT)\u003cbr\u003e100 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e142 (ND\/VT)\u003cbr\u003e115 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860115549,"sku":"CFW500G0142T4NB20G2","price":6160.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RE63KSV43US1ANB0.jpg?v=1766453417"},{"product_id":"cfw500g0180t4nb20g2-weg-150hp-vt-125hp-ct-variable-speed-drive-380-480vac-3ph","title":"CFW500G0180T4NB20G2 WEG 150HP-VT, 125HP-CT Variable Speed Drive, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0180T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e150 (ND\/VT)\u003cbr\u003e125 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e180 (ND\/VT)\u003cbr\u003e142 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860148317,"sku":"CFW500G0180T4NB20G2","price":7550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7OCA7A253US1ANB0.jpg?v=1766453417"},{"product_id":"cfw500g0211t4nb20g2-weg-175hp-vt-150hp-ct-variable-speed-drive-380-480vac-3-ph","title":"CFW500G0211T4NB20G2 WEG 175HP-VT, 150HP-CT Variable Speed Drive, 380-480VAC 3 PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0211T4NB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e175 (ND\/VT)\u003cbr\u003e150 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e211 (ND\/VT)\u003cbr\u003e180 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860181085,"sku":"CFW500G0211T4NB20G2","price":8758.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3R8SQN453US1ANB0.jpg?v=1766453417"},{"product_id":"cfw500g0142t4db20g2-weg-100-125hp-vt-100hp-ct-variable-speed-380-480vac-3ph","title":"CFW500G0142T4DB20G2 WEG 100\/125HP-VT, 100HP-CT Variable Speed, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0142T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e125 (ND\/VT)\u003cbr\u003e100 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e142 (ND\/VT)\u003cbr\u003e115 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.60 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860213853,"sku":"CFW500G0142T4DB20G2","price":6592.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V87BGG753US1ANB0.jpg?v=1766453418"},{"product_id":"cfw500g0180t4db20g2-weg-150hp-vt-125hp-ct-variable-speed-drive-380-480vac-3ph","title":"CFW500G0180T4DB20G2 WEG 150HP-VT, 125HP-CT Variable Speed Drive, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0180T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e150 (ND\/VT)\u003cbr\u003e125 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e180 (ND\/VT)\u003cbr\u003e142 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860246621,"sku":"CFW500G0180T4DB20G2","price":8078.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RM1Q3U953US1ANB0.jpg?v=1766453419"},{"product_id":"cfw500g0211t4db20g2-weg-175hp-vt-150hp-ct-variable-speed-drive-380-480vac-3ph","title":"CFW500G0211T4DB20G2 WEG 175HP-VT, 150HP-CT Variable Speed Drive, 380-480VAC 3PH","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWEG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eCFW500G0211T4DB20G2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Voltage\u003c\/td\u003e\n\u003ctd\u003e460VAC\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor HP\u003c\/td\u003e\n\u003ctd\u003e175 (ND\/VT)\u003cbr\u003e150 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive Amps\u003c\/td\u003e\n\u003ctd\u003e211 (ND\/VT)\u003cbr\u003e180 (HD\/CT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Transistor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd\u003e26.6\" x 13.2\" x 12.4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e114.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e  \u003cul\u003e\n\u003cli\u003eExtruders\u003c\/li\u003e\n\u003cli\u003eConveyor Belts\u003c\/li\u003e\n\u003cli\u003eRoller Tables\u003c\/li\u003e\n\u003cli\u003eFan \/ Exhausters\u003c\/li\u003e\n\u003cli\u003eCentrifugal Pumps\u003c\/li\u003e\n\u003cli\u003eGranulators \/ Palletizers\u003c\/li\u003e\n\u003cli\u003eCutting and Welding Machines\u003c\/li\u003e\n\u003cli\u003eDryers and Rotary Ovens\u003c\/li\u003e\n\u003cli\u003eProcess Dosing Pumps\u003c\/li\u003e\n\u003cli\u003eStirrers \/ Mixers\u003c\/li\u003e\n\u003cli\u003eRotary Filters\u003c\/li\u003e\n\u003cli\u003eWinding Machines \/ Uncoiling Machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSpecial engineering units (RPM, ï¿½C, Nm, mA, %, kW, kWh)\u003c\/li\u003e\n\u003cli\u003ePassword to protect the parameters\u003c\/li\u003e\n\u003cli\u003eBackup of all parameters (via SuperDrive G2 software, or plugin memory MMF)\u003c\/li\u003e\n\u003cli\u003ePossibility to save up to two different settings on the memory of the CFW500\u003c\/li\u003e\n\u003cli\u003eSetting of the switching frequency according to the application requirements\u003c\/li\u003e\n\u003cli\u003eSpeed reference via electronic potentiometer\u003c\/li\u003e\n\u003cli\u003eMultispeed with up to eight programmable speeds\u003c\/li\u003e\n\u003cli\u003eSlip compensation\u003c\/li\u003e\n\u003cli\u003eManual or automatic torque boost (V\/F scalar mode) or self-adjustment (VVW and vector modes)\u003c\/li\u003e\n\u003cli\u003ePermanent magnet motor control: VVW PM\u003c\/li\u003e\n\u003cli\u003eAcceleration\/deceleration ramps\u003c\/li\u003e\n\u003cli\u003eï¿½Sï¿½ type ramp\u003c\/li\u003e\n\u003cli\u003eDC braking\u003c\/li\u003e\n\u003cli\u003eInternal dynamic braking (except frame size A)\u003c\/li\u003e\n\u003cli\u003ePID controller to control processes in closed loop\u003c\/li\u003e\n\u003cli\u003eFlying start \/ Ride-through\u003c\/li\u003e\n\u003cli\u003eSleep mode\u003c\/li\u003e\n\u003cli\u003eSkip frequencies or frequency ranges function adjustable\u003c\/li\u003e\n\u003cli\u003eOverload and overtemperature protection\u003c\/li\u003e\n\u003cli\u003eOvercurrent protection\u003c\/li\u003e\n\u003cli\u003eDC link voltage supervision\u003c\/li\u003e\n\u003cli\u003eFault log\u003c\/li\u003e\n\u003cli\u003eSafety functions: STO and SS1\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eTolerance: -15 to +10%\u003cbr\u003eFrequency: 50\/60Hz (48 to 62 Hz)\u003cbr\u003ePhase Imbalance: =3% of the rated phase-phase input voltage\u003cbr\u003eTransient Voltages and Overvoltages according to Category III (EN 61010\/UL 508C)\u003cbr\u003eMaximum of 10 (line) connections per hour (1 every 6 minutes)\u003cbr\u003eTypical efficiency: =97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/F (scalar)\u003cbr\u003eVVW: voltage vector control\u003cbr\u003eVector without encoder (sensorless) and closed loop vector with encoder\u003cbr\u003ePM VVW: voltage vector control for permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 500 Hz\u003cbr\u003e0.015 Hz Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated input. Levels: (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003e\r\nLinearity error =0.25%\u003cbr\u003e\r\nImpedance: 100 kO for voltage input, 500 O for current input\u003cbr\u003e\r\nProgrammable functions, including PTC input\u003cbr\u003e\r\nMaximum voltage accepted in the inputs: 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e4 isolated inputs\u003cbr\u003eProgrammable functions:\u003cbr\u003eActive high (PNP): maximum low level of 15 VDC; minimum high level of 20 VDC\u003cbr\u003eActive low (NPN): maximum low level of 5 VDC; minimum high level of 9 VDC\u003cbr\u003eMaximum input voltage of 30 VDC\u003cbr\u003eInput current: 4.5 mA\u003cbr\u003eMaximum input current: 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated output. Levels (0 to 10) V or (0 to 20) mA or (4 to 20) mA\u003cbr\u003eLinearity error =0.25%\u003cbr\u003eProgrammable functions\u003cbr\u003eRL =10 kO (0 to 10 V) or RL =500 O (0 to 20 mA \/ 4 to 20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e1 relay with NO\/NC contact\u003cbr\u003eMaximum voltage: 240 VAC\u003cbr\u003eMaximum current of 0.5 A\u003cbr\u003eProgrammable functions\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransistor Outputs\u003c\/td\u003e\n\u003ctd\u003e1 isolated open sink digital output (using as reference the 24 V dc power supply)\u003cbr\u003eMaximum current of 150 mA (maximum capacity of the 24 V dc power supply)\u003cbr\u003eProgrammable functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC power supply\u003cbr\u003eMaximum capacity: 150 mA\u003cbr\u003ePower supply of 10 VDC\u003cbr\u003eMaximum capacity: 2 mA\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Options\u003c\/td\u003e\n\u003ctd\u003eFieldbus: Modbus-RTU, CANopen, DeviceNet, Profibus-DP, EtherNet\/IP, Modbus-TCP, PROFINET IO, USB, RS485 and RS232 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Protection\u003c\/td\u003e\n\u003ctd\u003ePhase-Phase \/ Phase-Ground overcurrent \/ Short Circuit\u003cbr\u003eUndervoltage\/Overvoltage\u003cbr\u003eHeatsink Overtemperature\u003cbr\u003eMotor Overload\u003cbr\u003ePower Module (IGBTs) Overload\u003cbr\u003eExternal fault \/ alarm\u003cbr\u003eProgramming error\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Interface\u003c\/td\u003e\n\u003ctd\u003e9 keys: Run\/Stop, Increment, Decrement, Direction of rotation, Jog, Local\/Remote, Back\/Esc and Enter\/Menu\u003cbr\u003e\r\nLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Degree\u003c\/td\u003e\n\u003ctd\u003eIP20 ï¿½ Sizes A, B, C, D, E, F and G\u003cbr\u003eNEMA1 ï¿½ Sizes A, B, C, D, E, F and G with NEMA1 Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 1,000 m (maximum altitude under normal conditions)\u003cbr\u003e1,000 to 4,000 m: current derating of 1% for each 100 m above 1,000 m of altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 ï¿½C to 50 ï¿½C - IP20 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - NEMA 1 (sizes A to E)\u003cbr\u003e-10 ï¿½C to 40 ï¿½C - IP20, NEMA 1 (size F)\u003cbr\u003e-10 ï¿½C to 45 ï¿½C - IP20, NEMA 1 (size G)\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\n\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/Dimensions.webp\" style=\"Width:80%;\" alt=\"WEG CFW500 Dimensions\"\u003e \u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEG-CFW500-IP20-G2-brochure-50109053-en.pdf\" target=\"_blank\"\u003eWEG CFW500 Variable Speed Drive Brochure (PDF, 20 Pages, 9.45MB)\u003c\/a\u003e\u003c\/div\u003e\n\u003ch3\u003eVideo\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003ciframe width=\"80%\" height=\"80%\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/L7StJzGIWXo\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915860279389,"sku":"CFW500G0211T4DB20G2","price":9371.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7041L0C53US1ANB0.jpg?v=1766453420"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/9DHO0SDF0US1ANB0.jpg?v=1766430835","url":"https:\/\/witmermotor.com\/collections\/cfw500-g2.oembed?page=4","provider":"Witmer Motor Service","version":"1.0","type":"link"}