{"title":"Fuji FRENIC-MEGA G2 Variable Speed Drives, 460VAC","description":"","products":[{"product_id":"frenic-mega-g2-series-1-2hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 1\/2HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121833565,"sku":"FRN0002G2S-4GU","price":575.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/A28H86MCE1T1ANB0.jpg?v=1766457454"},{"product_id":"frenic-mega-g2-series-1hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 1HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121866333,"sku":"FRN0003G2S-4GU","price":580.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PEVHAGUCE1T1ANB0.jpg?v=1766457457"},{"product_id":"frenic-mega-g2-series-2hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 2HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121899101,"sku":"FRN0004G2S-4GU","price":660.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PREM3K1DE1T1ANB0.jpg?v=1766457455"},{"product_id":"frenic-mega-g2-series-3hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 3HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121931869,"sku":"FRN0006G2S-4GU","price":752.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PUVM746DE1T1ANB0.jpg?v=1766457455"},{"product_id":"frenic-mega-g2-series-5hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 5HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121964637,"sku":"FRN0009G2S-4GU","price":917.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PUUG3J9DE1T1ANB0.jpg?v=1766457457"},{"product_id":"frenic-mega-g2-series-10hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 10HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916121997405,"sku":"FRN0018G2S-4GU","price":996.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P0KOU1DDE1T1ANB0.jpg?v=1766457457"},{"product_id":"frenic-mega-g2-series-15hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 15HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122030173,"sku":"FRN0023G2S-4GU","price":1344.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P84BTRGDE1T1ANB0.jpg?v=1766457457"},{"product_id":"frenic-mega-g2-series-20hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 20HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122062941,"sku":"FRN0035G2S-4GU","price":1638.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PJ12PAKDE1T1ANB0.jpg?v=1766457460"},{"product_id":"frenic-mega-g2-series-25hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 25HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122095709,"sku":"FRN0041G2S-4GU","price":2201.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PT72N4ODE1T1ANB0.jpg?v=1766457459"},{"product_id":"frenic-mega-g2-series-30hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 30HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122128477,"sku":"FRN0045G2S-4GU","price":2934.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9C2ALURDE1T1ANB0.jpg?v=1766457459"},{"product_id":"frenic-mega-g2-series-40hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 40HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122161245,"sku":"FRN0060G2S-4GU","price":3351.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PT5ME2VDE1T1ANB0.jpg?v=1766457460"},{"product_id":"frenic-mega-g2-series-50hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 50HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122194013,"sku":"FRN0085G2S-4GU","price":3937.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9AEGF73EE1T1ANB0.jpg?v=1766457460"},{"product_id":"frenic-mega-g2-series-60hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 60HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122226781,"sku":"FRN0105G2S-4GU","price":4802.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PJ56HC7EE1T1ANB0.jpg?v=1766457462"},{"product_id":"frenic-mega-g2-series-75hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 75HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122259549,"sku":"FRN0139G2S-4GU","price":5355.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9689CRAEE1T1ANB0.jpg?v=1766457462"},{"product_id":"frenic-mega-g2-series-150hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 150HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122292317,"sku":"FRN0217G2W-4GU","price":8631.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9T3IN6KEE1T1ANB0.jpg?v=1766457463"},{"product_id":"frenic-mega-g2-series-100hp-inverter-variable-frequency-drive-460vac-3-phase","title":"FRENIC-MEGA G2 Series 100HP Inverter \/ Variable Frequency Drive, 460VAC 3-Phase","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\u003cp\u003eA high-performance, multi-functional inverter optimized for a wide variety of HVAC applications that delivers greater longevity, simplifies system design and helps reduce energy use. Utilizing FRENIC-MEGA (G2)’s customizable logic, end users can program the VFD to their unique application requirements and eliminate additional external control components traditionally needed, such as relays, timers, temperature controllers, small PLCs, etc. This results in streamlined system designs with fewer points of failure, increasing overall reliability while also delivering additional performance.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eFaster Motor Operating Speeds (0-599Hz)\u003c\/li\u003e\n\u003cli\u003eEnhanced Response Times: 1000Hz Current Sampling\u003c\/li\u003e\n\u003cli\u003eEnhanced Torque Control\u003c\/li\u003e\n\u003cli\u003eAdvanced Dynamic Torque Vector Control\u003c\/li\u003e\n\u003cli\u003eImproved ability to handle impact loads\u003c\/li\u003e\n\u003cli\u003eNew Auto-Tuning Features for any motor.\u003c\/li\u003e\n\u003cli\u003eHigh-Precision Positioning Control\u003c\/li\u003e\n\u003cli\u003eCapable of Rotator Orientation Positioning\u003c\/li\u003e\n\u003cli\u003ePID Auto-Tuning\u003c\/li\u003e\n\u003cli\u003eLoad Limiter\u003c\/li\u003e\n\u003cli\u003eAdaptive Load Control\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic Functions (260 Steps, 58 Logical Functions)\u003c\/li\u003e\n\u003cli\u003ePID Control (with up to 4 PIDS)\u003c\/li\u003e\n\u003cli\u003eCascade Operation\u003c\/li\u003e\n\u003cli\u003eClogged Air Filter Remediation\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eSupports a variety of networks via option cards\u003c\/li\u003e\n\u003cli\u003eRS-485 Communication via Terminal Block\u003c\/li\u003e\n\u003cli\u003eSame mounting dimensions as FRENIC-MEGA (G1) Series\u003c\/li\u003e\n\u003cli\u003eEasy Parameter Migration\u003c\/li\u003e\n\u003cli\u003eHistory\/Traceback Function\u003c\/li\u003e\n\u003cli\u003eEnhanced PC Loader Functions\u003c\/li\u003e\n\u003cli\u003e10 year design life expectancy with Diagnosis and Maintenance Functions\u003c\/li\u003e\n\u003cli\u003eAccepts Safety Interlocking\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eGlobally compliant with safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application1.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application2.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application3.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application4.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application5.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application6.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application7.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application8.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application9.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/Application10.jpg\" alt=\"Fuji FRENIC-MEGA G2 Application\" width=\"80%\"\u003e\n\u003c\/center\u003e\n\u003cp align=\"right\"\u003e\u003ca href=\"#\"\u003eGo to top\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eHow to Read Model Numbers\u003c\/h3\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/readmodel.jpg\" alt=\"Fuji FRENIC-MEGA G2 Model Numbers\" width=\"80%\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003ch3\u003eWiring Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BasicWiring_sm.jpg\" alt=\"Fuji FRENIC-MEGA G2 Wiring Diagram\" width=\"80%\"\u003e\u003c\/center\u003e\n\u003col\u003e\n\u003cli\u003eInstall the molded case circuit breaker (MCCB) or earth leakage circuit breaker (ELCB) (with overcurrent protection function) recommended for each inverter on the inverter input side (primary side) to protect wiring. Do\r\r\r\r\r\nnot use a circuit breaker that exceeds the recommended rated current.\u003c\/li\u003e\n\u003cli\u003eAn MCCB or ELCB is also used if isolating the inverter from the power supply, and therefore the magnetic contactor (MC) recommended for each inverter should be installed if required. Please note that if installing a coil\r\r\r\r\r\nsuch as an MC or solenoid near the inverter, connect a surge absorber in parallel.\u003c\/li\u003e\n\u003cli\u003eIf you wish to retain the integrated alarm signal issued if the protective function is triggered even when the inverter main power supply is cut off, or to constantly display the keypad, connect these terminals to the power supply. (on FRN0008G2[][]-2G or higher \/FRN0008G2[][]-4G or higher) The inverter can be run even without inputting the power supply to these terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eRemove the shorting bar between the inverter main circuit terminals P1 and P(+) before connecting the DC reactor (DCR) (option). Be sure to connect the DC reactor in the case of FRN0139G2[][]-4G ND \/ FRN0288G2[][]-2G HND \/ FRN0179G2[][]-4G HND, HD, ND specification and FRN0346G2[][]-2G or higher \/ FRN0217G2[][]-4G or higher inverters. Use a DC reactor (DCR) when the capacity of the power supply transformer is 500 kVA or more and is 10 times or more the inverter rated capacity, or when there are \"thyristor driven\" loads.\u003c\/li\u003e\n\u003cli\u003eFRN0288G2[][]-2G or lower \/ FRN0217G2[][]-4G or lower inverters are equipped with a built-in braking transistor, allowing direct connection of braking resistors between P(+) and DB. If connecting a braking resistor (DB) (option) to FRN0346G2[][]-2G or higher \/ FRN0261G2[][]-4G or higher inverters, a braking unit (BU) (option) is necessary. A built-in braking resistor is connected between terminals P(+) and DB on FRN0046G2[][]-2G or lower \/FRN0023G2[][]-4G or lower inverters. If connecting a braking resistor (DB), be sure to disconnect the built-in braking resistor.\u003c\/li\u003e\n\u003cli\u003eThis terminal is used for grounding the motor. Connect if required.\u003c\/li\u003e\n\u003cli\u003eUse twisted wire or shielded wire for control signal lines. Shielded wires are generally grounded, however, if subject to significant induction noise from outside, it may be possible to suppress the effect of the noise by connecting wires to [CM]. Isolate control signal lines from the main circuit wiring as best as possible, and do not run inside the same duct (a distance of 10 cm or greater is recommended.) If lines intersect, ensure that they do so almost perpendicularly to the main circuit wiring.\u003c\/li\u003e\n\u003cli\u003eEach of the functions described for terminals [FWD] and [REV], terminals [X1] to [X9] (digital input), terminals [Y1] to [Y4] (transistor output), terminal [Y5A\/C], and terminal [30A\/B\/C] (contact output) indicate functions assigned by factory default.\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eThese are the switches on the control PCBs and are used to specify settings for inverter operation. Refer to the User's Manual Section 2.2.7 for details.\u003c\/li\u003e\n\u003cli\u003eSafety function terminals [EN1] and [EN2] are disabled with SW7 (2-pole switch) on the control PCB by factory default. If using this terminal function, be sure to change the respective SW7 switches to the OFF position and connect.\u003c\/li\u003e\n\u003cli\u003eInstall a thermal relay if necessary. Make the circuit breakers (MCCB) or the magnetic contactors (MC) trip by the thermal relay auxiliary contacts (manual recovery).\u003c\/li\u003e\n\u003cli\u003e[0V] and (0V) are separated and insulated.\u003c\/li\u003e\n\u003cli\u003eThe factory default setting for SW1 of FRN[][][][]G2E-4G is \"SOURCE\".\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0166b__MEGA_G2.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Catalog (PDF, 66 Pages, 13.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-G2_IM_E_INR-SI47-2599-E.pdf?v=1773771562\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Instruction Manual (PDF, 2 Pages, 507KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEA-ACDR-AN-204-MEGAG2-Single-Phase-Rating.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA (G2) Single Phase Rating Application Note (PDF, 5 Pages, 371KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43916122325085,"sku":"FRN0179G2W-4GU","price":6693.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9FFI8AEEE1T1ANB0.jpg?v=1766457463"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/KVE8KIBBE1T1ANB0.jpg?v=1766431041","url":"https:\/\/witmermotor.com\/collections\/460vac-2.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}