{"title":"Teco-Westinghouse A510 Heavy Duty AC Drives, 460VAC","description":"","products":[{"product_id":"a510-4060-c3-u-teco-westinghouse-60hp-45kw-heavy-duty-ac-drive","title":"A510-4060-C3-U Teco-Westinghouse 60HP\/45kW Heavy Duty AC Drive","description":"A510 HEAVY DUTY\r\r\n\r\r\nA versatile AC Drive that can control today's demanding motor driven applications, this highly flexible drive has multiple control modes.\r\r\n\r\r\nAPPLICATIONS:\r\r\n• Mixing\r\r\n• Pumps (Centrifugal, Positive Displacement, Metering, etc.)\r\r\n• Conveyors\r\r\n• Extrusion and Injection Molding\r\r\n• Packaging Machines\r\r\n• Winders \/ Unwinders\r\r\n• Machine Tools\r\r\n• Crushers\/Grinders\r\r\n• Fans\r\r\n• Crane \/ Hoist\r\r\n• Compressors\r\r\n\r\r\nFEATURES:\r\r\n• Control Modes for V\/F, V\/F with PG feedback, Sensorless Vector, and Closed Loop Vector\r\r\n• Simple PLC Function Built-in\r\r\n• Advanced Regenerative Load Handling Capability\r\r\n• 1 to 200 HP (CT), 460V, 50\/ 60Hz,3-Phase\r\r\n• 1 to 250 HP (VT), 460V, 50\/ 60Hz,3-Phase\r\r\n• Conformal Coating on PC Boards\r\r\n• LCD Keypad that is Remotely Mountable\r\r\n• Flexible Input\/ Output Configurations that Accept Normally Open or Normally Closed Signals\r\r\n• 0 to 599 Hz Speed Range\r\r\n• PID Control \r\r\n• Diagnostics Registers for Troubleshooting\r\r\n• Built-in RS485 Modbus Protocol\r\r\n• Enhanced Design for Quiet Motor Operation\r\r\n• Pulse Output and Pulse Follower\r\r\n• Select Between Closed-Loop Speed and Torque Control in Vector Mode\r\r\n• 1-60HP NEMA 1 460V \u0026amp; 75HP and Above Protected chassis\r\r\n• UL, cUL, and CE approved","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915332550749,"sku":"A510-4060-C3-U","price":2948.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/UEI01GOO435RON50.jpg?v=1766444659"},{"product_id":"a510-4100-c3-ue-teco-westinghouse-100hp-heavy-duty-ac-drive-460vac","title":"A510-4100-C3-UE Teco-Westinghouse 100HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4100-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e100 HP (Constant Torque)\u003cbr\u003e125 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e150.0 Amps (Constant Torque)\u003cbr\u003e168.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e22.83 inches\u003cbr\u003e580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e13.7 inches\u003cbr\u003e344 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e11.81 inches\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e102.9 lbs\u003cbr\u003e46.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915332616285,"sku":"A510-4100-C3-UE","price":7198.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MF0CE7QO435RON50.jpg?v=1766444659"},{"product_id":"a510-4001-c3-ue-teco-westinghouse-1hp-heavy-duty-ac-drive-460vac","title":"A510-4001-C3-UE Teco-Westinghouse 1HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4001-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e1 HP (Constant Torque)\u003cbr\u003e2 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e3.4 Amps (Constant Torque)\u003cbr\u003e4.1 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e9.61 inches\u003cbr\u003e244 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e5.12 inches\u003cbr\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e5.91 inches\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e5.5 lbs\u003cbr\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915916968029,"sku":"A510-4001-C3-UE","price":439.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LU9QSHCROUS1ANB0.jpg?v=1766454282"},{"product_id":"a510-4002-c3-ue-teco-westinghouse-2hp-heavy-duty-ac-drive-460vac","title":"A510-4002-C3-UE Teco-Westinghouse 2HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4002-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e2 HP (Constant Torque)\u003cbr\u003e3 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e4.2 Amps (Constant Torque)\u003cbr\u003e5.4 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e9.61 inches\u003cbr\u003e244 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e5.12 inches\u003cbr\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e5.91 inches\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e5.5 lbs\u003cbr\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917000797,"sku":"A510-4002-C3-UE","price":459.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JCID83IROUS1ANB0.jpg?v=1766454282"},{"product_id":"a510-4003-c3-ue-teco-westinghouse-3hp-heavy-duty-ac-drive-460vac","title":"A510-4003-C3-UE Teco-Westinghouse 3HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4003-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e3 HP (Constant Torque)\u003cbr\u003e3 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e5.5 Amps (Constant Torque)\u003cbr\u003e6.9 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e9.61 inches\u003cbr\u003e244 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e5.12 inches\u003cbr\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e5.91 inches\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e5.5 lbs\u003cbr\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917033565,"sku":"A510-4003-C3-UE","price":547.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/17DQJFJROUS1ANB0.jpg?v=1766454283"},{"product_id":"a510-4005-c3-ue-teco-westinghouse-5hp-heavy-duty-ac-drive-460vac","title":"A510-4005-C3-UE Teco-Westinghouse 5HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4005-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e5 HP (Constant Torque)\u003cbr\u003e5 to 7.5 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e9.2 Amps (Constant Torque)\u003cbr\u003e12.1 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e12.40 inches\u003cbr\u003e315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e5.51 inches\u003cbr\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e6.97 inches\u003cbr\u003e177 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e8.8 lbs\u003cbr\u003e4.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917066333,"sku":"A510-4005-C3-UE","price":623.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FOVNURKROUS1ANB0.jpg?v=1766454283"},{"product_id":"a510-4008-c3-ue-teco-westinghouse-7-5hp-heavy-duty-ac-drive-460vac","title":"A510-4008-C3-UE Teco-Westinghouse 7.5HP HEavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4008-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e7.5 HP (Constant Torque)\u003cbr\u003e10 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e14.8 Amps (Constant Torque)\u003cbr\u003e17.5 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e12.40 inches\u003cbr\u003e315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e5.51 inches\u003cbr\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e6.97 inches\u003cbr\u003e177 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e8.8 lbs\u003cbr\u003e4.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917099101,"sku":"A510-4008-C3-UE","price":888.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T9IL98MROUS1ANB0.jpg?v=1766454284"},{"product_id":"a510-4010-c3-ue-teco-westinghouse-10hp-heavy-duty-ac-drive-460vac","title":"A510-4010-C3-UE Teco-Westinghouse 10HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4010-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e10 HP (Constant Torque)\u003cbr\u003e15 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps (Constant Torque)\u003cbr\u003e23.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e11.81 inches\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e8.27 inches\u003cbr\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e8.46 inches\u003cbr\u003e215 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e13.6 lbs\u003cbr\u003e6.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917131869,"sku":"A510-4010-C3-UE","price":1016.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RIIKDOQROUS1ANB0.jpg?v=1766454285"},{"product_id":"a510-4015-c3-ue-teco-westinghouse-15hp-heavy-duty-ac-drive-460vac","title":"A510-4015-C3-UE Teco-Westinghouse 15HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4015-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e15 HP (Constant Torque)\u003cbr\u003e20 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e24.0 Amps (Constant Torque)\u003cbr\u003e31.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e11.81 inches\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e8.27 inches\u003cbr\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e8.46 inches\u003cbr\u003e215 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e13.6 lbs\u003cbr\u003e6.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917164637,"sku":"A510-4015-C3-UE","price":1217.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9P6LO4SROUS1ANB0.jpg?v=1766454285"},{"product_id":"a510-4020-c3-ue-teco-westinghouse-20hp-heavy-duty-ac-drive-460vac","title":"A510-4020-C3-UE Teco-Westinghouse 20HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4020-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e20 HP (Constant Torque)\u003cbr\u003e25 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e31.0 Amps (Constant Torque)\u003cbr\u003e38.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e11.81 inches\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e8.27 inches\u003cbr\u003e210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e8.46 inches\u003cbr\u003e215 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e13.6 lbs\u003cbr\u003e6.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917197405,"sku":"A510-4020-C3-UE","price":1455.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NI6B4HTROUS1ANB0.jpg?v=1766454286"},{"product_id":"a510-4025-c3-ue-teco-westinghouse-25hp-heavy-duty-ac-drive-460vac","title":"A510-4025-C3-UE Teco-Westinghouse 25HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4025-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e25 HP (Constant Torque)\u003cbr\u003e30 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e39.0 Amps (Constant Torque)\u003cbr\u003e44.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e14.17 inches\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e10.43 inches\u003cbr\u003e265 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e8.86 inches\u003cbr\u003e225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e22.0 lbs\u003cbr\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917230173,"sku":"A510-4025-C3-UE","price":1809.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LUDAH8VROUS1ANB0.jpg?v=1766454286"},{"product_id":"a510-4030-c3-ue-teco-westinghouse-30hp-heavy-duty-ac-drive-460vac","title":"A510-4030-C3-UE Teco-Westinghouse 30HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4030-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e30 HP (Constant Torque)\u003cbr\u003e40 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e45.0 Amps (Constant Torque)\u003cbr\u003e58.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e14.17 inches\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e10.43 inches\u003cbr\u003e265 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e8.86 inches\u003cbr\u003e225 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e22.0 lbs\u003cbr\u003e10.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917262941,"sku":"A510-4030-C3-UE","price":1925.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JKKFSK0SOUS1ANB0.jpg?v=1766454287"},{"product_id":"a510-4040-c3-ue-teco-westinghouse-40hp-heavy-duty-ac-drive-460vac","title":"A510-4040-C3-UE Teco-Westinghouse 40HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4040-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e40 HP (Constant Torque)\u003cbr\u003e50 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e60.0 Amps (Constant Torque)\u003cbr\u003e73.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e20.67 inches\u003cbr\u003e525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e11.18 inches\u003cbr\u003e284 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e9.92 inches\u003cbr\u003e252 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e66.1 lbs\u003cbr\u003e30.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917295709,"sku":"A510-4040-C3-UE","price":2556.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/H0KE5M1SOUS1ANB0.jpg?v=1766454287"},{"product_id":"a510-4050-c3-ue-teco-westinghouse-50hp-heavy-duty-ac-drive-460vac","title":"A510-4050-C3-UE Teco-Westinghouse 50HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4050-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e50 HP (Constant Torque)\u003cbr\u003e60 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e75.0 Amps (Constant Torque)\u003cbr\u003e88.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e20.67 inches\u003cbr\u003e525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e11.18 inches\u003cbr\u003e284 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e9.92 inches\u003cbr\u003e252 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e66.1 lbs\u003cbr\u003e30.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917328477,"sku":"A510-4050-C3-UE","price":3084.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V736G23SOUS1ANB0.jpg?v=1766454288"},{"product_id":"a510-4060-c3-ue-teco-westinghouse-60hp-heavy-duty-ac-drive-460vac","title":"A510-4060-C3-UE Teco-Westinghouse 60HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4060-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e60 HP (Constant Torque)\u003cbr\u003e75 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e91.0 Amps (Constant Torque)\u003cbr\u003e103.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e20.67 inches\u003cbr\u003e525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e11.18 inches\u003cbr\u003e284 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e9.92 inches\u003cbr\u003e252 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e66.1 lbs\u003cbr\u003e30.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917361245,"sku":"A510-4060-C3-UE","price":3515.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TU42RE4SOUS1ANB0.jpg?v=1766454289"},{"product_id":"a510-4075-c3-ue-teco-westinghouse-75hp-heavy-duty-ac-drive-460vac","title":"A510-4075-C3-UE Teco-Westinghouse 75HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4075-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e75 HP (Constant Torque)\u003cbr\u003e100 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e118.0 Amps (Constant Torque)\u003cbr\u003e145.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e20.67 inches\u003cbr\u003e525 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e11.18 inches\u003cbr\u003e284 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e9.92 inches\u003cbr\u003e252 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e77.1 lbs\u003cbr\u003e35.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eNEMA 1 (IP20) \/ F5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917394013,"sku":"A510-4075-C3-UE","price":4397.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RL6U5R5SOUS1ANB0.jpg?v=1766454288"},{"product_id":"a510-4125-c3-ue-teco-westinghouse-125hp-heavy-duty-ac-drive-460vac","title":"A510-4125-C3-UE Teco-Westinghouse 125HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4125-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e125 HP (Constant Torque)\u003cbr\u003e150 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e180.0 Amps (Constant Torque)\u003cbr\u003e208.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e22.83 inches\u003cbr\u003e580 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e13.7 inches\u003cbr\u003e344 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e11.81 inches\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e102.9 lbs\u003cbr\u003e46.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917426781,"sku":"A510-4125-C3-UE","price":9233.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BKE8P88SOUS1ANB0.jpg?v=1766454289"},{"product_id":"a510-4150-c3-ue-teco-westinghouse-150hp-heavy-duty-ac-drive-460vac","title":"A510-4150-C3-UE Teco-Westinghouse 150HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4150-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e150 HP (Constant Torque)\u003cbr\u003e200 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e216.0 Amps (Constant Torque)\u003cbr\u003e250.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e31.10 inches\u003cbr\u003e790 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e18.08 inches\u003cbr\u003e459 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e12.78 inches\u003cbr\u003e324.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e194.0 lbs\u003cbr\u003e88.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917459549,"sku":"A510-4150-C3-UE","price":10675.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/90E72A9SOUS1ANB0.jpg?v=1766454290"},{"product_id":"a510-4215-c3-ue-teco-westinghouse-200hp-heavy-duty-ac-drive-460vac","title":"A510-4215-C3-UE Teco-Westinghouse 200HP HEavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4215-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e200 HP (Constant Torque)\u003cbr\u003e250 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e295.0 Amps (Constant Torque)\u003cbr\u003e328.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e31.10 inches\u003cbr\u003e790 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e18.08 inches\u003cbr\u003e459 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e12.78 inches\u003cbr\u003e324.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e194.0 lbs\u003cbr\u003e88.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917492317,"sku":"A510-4215-C3-UE","price":12401.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/N7TUCMASOUS1ANB0.jpg?v=1766454290"},{"product_id":"a510-4270-c3-ue-teco-westinghouse-250hp-heavy-duty-ac-drive-460vac","title":"A510-4270-C3-UE Teco-Westinghouse 250HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4270-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e250 HP (Constant Torque)\u003cbr\u003e250 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e380.0 Amps (Constant Torque)\u003cbr\u003e435.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e39.37 inches\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e27.16 inches\u003cbr\u003e690 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e16.14 inches\u003cbr\u003e410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e405 lbs\u003cbr\u003e184 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917525085,"sku":"A510-4270-C3-UE","price":15504.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LUUQN2CSOUS1ANB0.jpg?v=1766454291"},{"product_id":"a510-4300-c3-ue-teco-westinghouse-300hp-heavy-duty-ac-drive-460vac","title":"A510-4300-C3-UE Teco-Westinghouse 300HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4300-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e300 HP (Constant Torque)\u003cbr\u003e300 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e450.0 Amps (Constant Torque)\u003cbr\u003e515.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e39.37 inches\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e27.16 inches\u003cbr\u003e690 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e16.14 inches\u003cbr\u003e410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e405 lbs\u003cbr\u003e184 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917557853,"sku":"A510-4300-C3-UE","price":15826.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3GDO04DSOUS1ANB0.jpg?v=1766454292"},{"product_id":"a510-4375-c3-ue-teco-westinghouse-350hp-heavy-duty-ac-drive-460vac","title":"A510-4375-C3-UE Teco-Westinghouse 350HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4375-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e350 HP (Constant Torque)\u003cbr\u003e400 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e523.0 Amps (Constant Torque)\u003cbr\u003e585.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e39.37 inches\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e27.16 inches\u003cbr\u003e690 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e16.14 inches\u003cbr\u003e410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e405 lbs\u003cbr\u003e184 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917590621,"sku":"A510-4375-C3-UE","price":18460.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/18ABBGESOUS1ANB0.jpg?v=1766454293"},{"product_id":"a510-4425-c3-ue-teco-westinghouse-400hp-heavy-duty-ac-drive-460vac","title":"A510-4425-C3-UE Teco-Westinghouse 400HP Heavy Duty AC Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/accordion.css\"\u003e\n\u003cscript\u003e$(function() {\r\r\n $(\"#accordion\").accordion({\r\r\nheightStyle: \"content\",\r\r\ncollapsible: true,\r\r\nactive: false\r\r\n });\r\r\n});\r\r\n \u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe A510 Heavy Duty AC Drive is an easily configured versatile drive product that will control all general applications such as fans, pumps, conveyors, and mixers. It comes standard with a simple to select preset application parameters for many commonly used applications.\u003c\/p\u003e\n\u003cp\u003eDespite its simple and easy approach, the A510 is loaded with features to solve tough and demanding applications such as reciprocating pumps, compressors and high torque\/ high inertia loads\u003c\/p\u003e\n\u003cp\u003eAdvanced algorithms allow the A510 to perform tight and precise speed control when coupled with encoder feedback on the motor being controlled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eTeco-Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eA510-4425-C3-UE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480VAC\u003cbr\u003e50\/60Hz\u003cbr\u003e3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e400 HP (Constant Torque)\u003cbr\u003e400 HP (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003ctd\u003e585.0 Amps (Constant Torque)\u003cbr\u003e585.0 Amps (Variable Torque)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e39.37 inches\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e27.16 inches\u003cbr\u003e690 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e16.14 inches\u003cbr\u003e410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEst. Weight\u003c\/th\u003e\n\u003ctd\u003e405 lbs\u003cbr\u003e184 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagram\u003c\/th\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking DC Link Reactor\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eOpen Chassis (IP00) \/ F8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eCompressors\u003c\/li\u003e\n\u003cli\u003eMetals Processing: Industrial Saws, Punch Press and Screw and Bolt Manufacturing\u003c\/li\u003e\n\u003cli\u003eMachine Tool Operations: Grinding, Milling and Lathes\u003c\/li\u003e\n\u003cli\u003ePlastic and Rubber Process Machines: Extruders and Rubber Compounding\u003c\/li\u003e\n\u003cli\u003eCranes, Hoists and Materials Handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eSelectable Control Modes: \u003cbr\u003eV\/F Mode with constant and variable torque settings \u003cbr\u003eV\/F Mode with PG encoder feedback \u003cbr\u003eSensorless Vector \u003cbr\u003eSensorless Vector with permanent magnet motors \u003cbr\u003eClosed Loop Vector \u003cbr\u003eClosed Loop Vector with Permanent Magnet Motors \u003cbr\u003eSensorless vector control with dynamic control and rotational tuning \u003c\/li\u003e\n\u003cli\u003eAttains High Torque Levels: \u003cbr\u003e200% Starting torque in sensorless vector modes \u003cbr\u003e200% Holding torque in closed-loop vector modes \u003c\/li\u003e\n\u003cli\u003eSelect matching application type for quick setting of parameter defaults\u003c\/li\u003e\n\u003cli\u003eAdvanced regenerative energy handling capabilities with overvoltage suppression\u003c\/li\u003e\n\u003cli\u003eExtensive Monitoring and Display capabilities: \u003cbr\u003eDisplay over 40 different operating and status information variables \u003cbr\u003eRetains 4 most recent faults in a log \u003c\/li\u003e\n\u003cli\u003ePLC functionality built-in\u003c\/li\u003e\n\u003cli\u003eAdvanced tuning\/ motor matching capabilities\u003c\/li\u003e\n\u003cli\u003ePulse Width Modulation (PWM) technology\u003c\/li\u003e\n\u003cli\u003e32 Bit, 100 MHz processor for extremely fast response\u003c\/li\u003e\n\u003cli\u003eDigital I\/O: \u003cbr\u003e8 configurable digital inputs \u003cbr\u003e3 digital outputs \u003cbr\u003eSafety input contact for user’s interlock circuit \u003c\/li\u003e\n\u003cli\u003eAnalog I\/O: \u003cbr\u003e2 analog inputs \u003cbr\u003e1 0-10VDC analog output \u003cbr\u003e0-10VDC\/ 4-20mA output \u003c\/li\u003e\n\u003cli\u003ePulse I\/O: \u003cbr\u003e1 pulse input channel capable of up to 32 kHz \u003cbr\u003e1 pulse output channel capable of up to 32 kHz \u003c\/li\u003e\n\u003cli\u003eRemovable I\/O terminal strip\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOperating Characteristics\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eControl Modes\u003c\/th\u003e\n\u003ctd\u003eV\/F \u003cbr\u003eV\/F+PG \u003cbr\u003eSLV \u003cbr\u003eSV \u003cbr\u003ePMSV \u003cbr\u003ePMSLV \u003cbr\u003eSLV2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Control Range\u003c\/th\u003e\n\u003ctd\u003e0.1Hz to 599.99Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Accuracy (Temperature Change)\u003c\/th\u003e\n\u003ctd\u003eDigital references: ±0.01% (-10 to +40ºC) \u003cbr\u003eAnalog references: ±0.1% (25ºC ±10ºC) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpeed Control Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% (closed loop vector control) \u003cbr\u003e±0.5% (sensorless vector mode) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Resolution\u003c\/th\u003e\n\u003ctd\u003eDigital references: 0.01Hz \u003cbr\u003eAnalog references: 0.06Hz\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload Tolerance rated output current\u003c\/th\u003e\n\u003ctd\u003e150%\/1 min \u003cbr\u003e200%\/2sec (CT mode) \u003cbr\u003e120%\/1 min (VT mode) \u003cbr\u003efactory setting of 150%\/1 min \u003cbr\u003e200%\/2 sec \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency Setting Signal\u003c\/th\u003e\n\u003ctd\u003e0 to +10VDC \u003cbr\u003e4 to 20mA \u003cbr\u003e-10VDC to +10VDC \u003cbr\u003epulse–type frequency command \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAcceleration \/ Deceleration Time\u003c\/th\u003e\n\u003ctd\u003e0.0 to 6000.0 sec (separately set acceleration and deceleration times)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage and frequency characteristics\u003c\/th\u003e\n\u003ctd\u003eCan set custom V\/ F-curve based on parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking torque\u003c\/th\u003e\n\u003ctd\u003eApproxiamtely 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain control functions\u003c\/th\u003e\n\u003ctd\u003eAuto tuning \u003cbr\u003eshaft lock \u003cbr\u003etorque control \u003cbr\u003eposition control \u003cbr\u003edroop control \u003cbr\u003esoft-switching in PWM \u003cbr\u003eover-voltage protection \u003cbr\u003edynamic braking \u003cbr\u003espeed search \u003cbr\u003efrequency traversing \u003cbr\u003einstantaneous power fault restart \u003cbr\u003ePID control \u003cbr\u003eautomatic torque compensation \u003cbr\u003eslip compensation \u003cbr\u003eRS-485 communication MODBUS standard \u003cbr\u003espeed feedback control \u003cbr\u003esimple PLC functionality \u003cbr\u003e2 sets of analog output \u003cbr\u003esafety switch interlock \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional control functions\u003c\/th\u003e\n\u003ctd\u003eRecord of elapsed power-up and operation times \u003cbr\u003e4 most recent occurrences of faults and the most recent fault record \u003cbr\u003estatus \u003cbr\u003eenergy-saving function setting, single phasing protection \u003cbr\u003esmart braking \u003cbr\u003eDC braking \u003cbr\u003edwell \u003cbr\u003eS-curve acceleration and deceleration \u003cbr\u003eUp \/ Down operation \u003cbr\u003eMODBUS communication type \u003cbr\u003escale pulse output \u003cbr\u003eengineering unit display \u003cbr\u003eLocal\/remote switching keys \u003cbr\u003eSINK\/ SOURCE input interface options \u003cbr\u003estall protection \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication function\u003c\/th\u003e\n\u003ctd\u003eRS-485 standard with built-in (MODBUS) (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePLC function\u003c\/th\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMI protection\u003c\/th\u003e\n\u003ctd\u003eThe added noise filter complies with EM61800-3, 460V; 215 HP or below can be built-in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMS protection\u003c\/th\u003e\n\u003ctd\u003eFollows EN61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eProtection Features\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStall Protection\u003c\/th\u003e\n\u003ctd\u003eThreshold current can be set (in acceleration or constant speed, it can be set separately. In deceleration, it can be set on or off )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstantaneous Over Current (OC) \u003cbr\u003eOutput Short Circuit (SC) \u003c\/th\u003e\n\u003ctd\u003enverter shuts off when the current exceeds 200% of the inverter related current.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInverter Overload protection (OL2)\u003c\/th\u003e\n\u003ctd\u003eInverter rated current is 150%\/1 min, at 200%\/2 sec, inverter stops (CT type), carrier frequency factory setting is 8~2 kHz. At 120%\/1 min, inverter stops (VT type), carrier frequency factory setting is 2 kHz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Overload (OL1) protection\u003c\/th\u003e\n\u003ctd\u003eElectrical overload protection curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOver Voltage (OV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage exceeds 410V (230V units)\/ 820V (460V units), 1,050V (575V units)\/ 1,230V (690V units), the drive faults out regardless of whether it is in run mode or stopped.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnder Voltage (UV)\u003c\/th\u003e\n\u003ctd\u003eWhen the main circuit DC voltage is under 190V (230V units)\/ 380V (460V units), 546V (575V units)\/ 575V (690V units), the drive faults out regardless of whether it is in run mode or stopped. The DC voltage trigger level can be adjusted.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutomatic restart after instantaneous power fault\u003c\/th\u003e\n\u003ctd\u003ePower fault exceeds 15 ms. This is programmable to 2 seconds.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverheat protection (OH)\u003c\/th\u003e\n\u003ctd\u003eBy direct temperature detection in the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGround Fault protection (GF)\u003c\/th\u003e\n\u003ctd\u003eUses current feedback for protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection in charge state\u003c\/th\u003e\n\u003ctd\u003eWhen main circuit DC voltage exceeds 50V, the “CHARGE” LED is on.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Phase Loss Protection (OPL)\u003c\/th\u003e\n\u003ctd\u003eAutomatically stops motor rotation and faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003chr\u003e\n\u003ch4\u003eEnvironmental Specifications\u003c\/h4\u003e\n\u003cdiv class=\"productspecifications\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLocation\u003c\/th\u003e\n\u003ctd\u003eIndoor (protected from corrosive gases and dust)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 to +40°C without de-rating (IP20\/NEMA1) \u003cbr\u003e-10 to +50°C (IP00) \u003cbr\u003ewith de-rating, its maximum operation temperature is 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e95%RH or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003eAltitude of 1,000 m (3,300 ft) or lower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration\u003c\/th\u003e\n\u003ctd\u003ebelow 5.9 m\/s2 (0.6G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eConnection Diagram\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ccenter\u003e\u003cimg src=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510UE_Wiring.png\" alt=\"Teco-Westinghouse A510 UE Wiring Diamgram\" width=\"80%\" height=\"80%\"\u003e\u003c\/center\u003e\n\u003cp\u003eNotes:\u003c\/p\u003e\n\u003cp\u003e1: Models 230V 1  to 25HP and 460V 1 to 30HP or lower ratings have a built-in braking transistor. To use this braking transistor a braking resistor can be connected between B1 and B2.\u003c\/p\u003e\n\u003cp\u003e2: Use SW6 to select between Sink (NPN, with 24VG common) or Source (PNP, with +24V common) for multi-function digital input terminals S1 to S8.\u003c\/p\u003e\n\u003cp\u003e3: Use SW3\/SW4 to switch between voltage (0 to 10V) and current (4 to 20mA) input for Multi-function analog input 2 (AI2). Besides please also check parameter 04-00 for proper setting.\u003c\/p\u003e\n\u003cp\u003e4: Run Permissive input SF1 and SF2 is a normally closed input. This input should be closed to enable the inverter output. To activate this input remove the jumper wire between SF1\/ SF2 and SG.\u003c\/p\u003e\n\u003cp\u003e5: When using the open collector for pulse input, it doesn’t need resistance because of built-in pull-up resistance.\u003c\/p\u003e\n\u003cp\u003e6: AO1\/AO2 default setting is 0~+10V.\u003c\/p\u003e\n\u003cp\u003e7: Both 230V class 50HP to 150HP and 460V class 100HP to 425HP have built-in DC reactors.\u003c\/p\u003e\n\u003cp\u003e8: It need turn on the switch for the terminal resistor RS485 in the last inverter when many inverters in parallel connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_brochure.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Brochure (PDF, 16 Pages, 1.05MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_comm_addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Communication Addendum (PDF, 39 Pages, 1.66MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_instruction_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Instruction Manual (PDF, 459 Pages, 11.6MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_PLC_Addendum.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 PLC Addendum (PDF, 13 Pages, 825KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/A510_startup_installation_manual.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Start-Up and Installation Manual (PDF, 275 Pages, 9.44MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/510_copy_module.pdf\" target=\"_blank\"\u003eTeco-Westinghouse A510 Copy Module Instruction Manual (PDF, s Pages, 458KB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915917623389,"sku":"A510-4425-C3-UE","price":26288.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V9A4MSFSOUS1ANB0.jpg?v=1766454292"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/G77S3D5QOUS1ANB0.jpg?v=1766431031","url":"https:\/\/witmermotor.com\/collections\/460vac-1.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}