{"title":"Fuji FRENIC-MEGA Variable Frequency Drives, 380-480VAC","description":"","products":[{"product_id":"frn001g1s-4u-fuji-frenic-mega-1hp-inverter-variable-frequency-drive-460vac","title":"FRN001G1S-4U Fuji FRENIC-MEGA 1HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN001G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e2.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e4.4 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e1 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e1.2 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e2.0 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e1.5 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e2.5 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e3.1 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e2.6 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e1.8 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e1.5 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e0.9 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e1.2 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e150%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e4.4 lbs\u003cbr\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e4.33\"\u003cbr\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e3.78\"\u003cbr\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.69\"\u003cbr\u003e246 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.28\"\u003cbr\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e5.71\"\u003cbr\u003e145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.45\"\u003cbr\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e1.26\"\u003cbr\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.12\"\u003cbr\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303223389,"sku":"FRN001G1S-4U","price":484.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LI50EN86525RON50.jpg?v=1766444197"},{"product_id":"frn002g1s-4u-fuji-frenic-mega-2hp-inverter-variable-frequency-drive-460vac","title":"FRN002G1S-4U Fuji FRENIC-MEGA 2HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN002G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e4.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5.7 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e2 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e2.0 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e3.2 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e2.4 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e4.0 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD\/HD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e5.9 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e5.1 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e3.5 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e2.6 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.7 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e2.2\/2.1 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e5.7 lbs\u003cbr\u003e2.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e5.91\"\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e5.35\"\u003cbr\u003e136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.69\"\u003cbr\u003e246 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.28\"\u003cbr\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e5.71\"\u003cbr\u003e145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.45\"\u003cbr\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e1.26\"\u003cbr\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.12\"\u003cbr\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303321693,"sku":"FRN002G1S-4U","price":551.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/136GREA6525RON50.jpg?v=1766444200"},{"product_id":"frn003g1s-4u-fuji-frenic-mega-3hp-inverter-variable-frequency-drive-460vac","title":"FRN003G1S-4U Fuji FRENIC-MEGA 3HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN003G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e5.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.0 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1.5 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e3 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e2.4 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e4.4 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e3.0 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e5.5 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e8.2 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e7.1 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e4.7 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e4 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e2.2 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e3.1\/3.2 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e6.0 lbs\u003cbr\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e5.91\"\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e5.35\"\u003cbr\u003e136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.69\"\u003cbr\u003e246 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.28\"\u003cbr\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e5.71\"\u003cbr\u003e145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.45\"\u003cbr\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e1.26\"\u003cbr\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.12\"\u003cbr\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303387229,"sku":"FRN003G1S-4U","price":628.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/DI797RB6525RON50.jpg?v=1766444202"},{"product_id":"frn005g1s-4u-fuji-frenic-mega-5hp-inverter-variable-frequency-drive-460vac","title":"FRN005G1S-4U Fuji FRENIC-MEGA 5HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN005G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e9 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e6.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e5 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e4.5 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e7.2 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e5.6 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e9.0 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e13.0 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e11.3 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e8.5 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e6.6 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e4.0 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e5.2\/5.3 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e6.6 lbs\u003cbr\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e5.91\"\u003cbr\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e5.35\"\u003cbr\u003e136 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.69\"\u003cbr\u003e246 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.28\"\u003cbr\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e5.71\"\u003cbr\u003e145 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.45\"\u003cbr\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e1.26\"\u003cbr\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.12\"\u003cbr\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303452765,"sku":"FRN005G1S-4U","price":816.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/98NNKID6525RON50.jpg?v=1766444203"},{"product_id":"frn007g1s-4u-fuji-frenic-mega-7-5hp-inverter-variable-frequency-drive-460vac","title":"FRN007G1S-4U Fuji FRENIC-MEGA 7.5HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN007G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e13.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e7.5 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e6.4 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e11 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e8.0 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e13.5 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e17.3 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e15 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e11.7 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e9.2 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e5.4 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e7.4 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e70% (LD Mode)\u003cbr\u003e100% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e3.7 Seconds (LD Mode)\u003cbr\u003e5 Seconds (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e2.2% (LD Mode)\u003cbr\u003e3% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003cbr\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e8.66\"\u003cbr\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e7.72\"\u003cbr\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.37\"\u003cbr\u003e238 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303518301,"sku":"FRN007G1S-4U","price":831.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/59532AF6525RON50.jpg?v=1766444206"},{"product_id":"frn010g1s-4u-fuji-frenic-mega-10hp-inverter-variable-frequency-drive-460vac","title":"FRN010G1S-4U Fuji FRENIC-MEGA 10HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN010G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e16.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e5 HP with Single Phase Input (LD Mode)\u003cbr\u003e10 HP with 3-Phase Input (LD Mode)\u003cbr\u003e3 HP with Single Phase Input (HD Mode)\u003cbr\u003e7.5 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e8.8 kVA with Single Phase Input (LD Mode)\u003cbr\u003e13.1 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e6.4 kVA with Single Phase Input (HD Mode)\u003cbr\u003e11 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e11.0 Amps with Single Phase Input (LD Mode)\u003cbr\u003e16.5 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e8.0 Amps with Single Phase Input (HD Mode)\u003cbr\u003e13.5 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e23.2\/17.3 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e20.1\/15 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e15.7\/11.7 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e12.5\/9.2 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e7.3\/5.4 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e10\/7.4 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e70% (LD Mode)\u003cbr\u003e100% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e3.7 Seconds (LD Mode)\u003cbr\u003e5 Seconds (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e2.2% (LD Mode)\u003cbr\u003e3% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003cbr\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e8.66\"\u003cbr\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e7.72\"\u003cbr\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.37\"\u003cbr\u003e238 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303583837,"sku":"FRN010G1S-4U","price":872.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/10C8DMG6525RON50.jpg?v=1766444206"},{"product_id":"frn015g1s-4u-fuji-frenic-mega-15hp-inverter-variable-frequency-drive-460vac","title":"FRN015G1S-4U Fuji FRENIC-MEGA 15HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN015G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e23 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e7.5 HP with Single Phase Input (LD Mode)\u003cbr\u003e15 HP with 3-Phase Input (LD Mode)\u003cbr\u003e5 HP with Single Phase Input (HD Mode)\u003cbr\u003e10 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e12 kVA with Single Phase Input (LD Mode)\u003cbr\u003e18.3 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e9.6 kVA with Single Phase Input (HD Mode)\u003cbr\u003e15 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e15 Amps with Single Phase Input (LD Mode)\u003cbr\u003e23 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e12 Amps with Single Phase Input (HD Mode)\u003cbr\u003e18.5 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e33\/23.2 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e28.6\/20.1 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e24\/16.8 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e18.8\/12.4 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e11\/7.8 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e15\/9.9 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e70% (LD Mode)\u003cbr\u003e100(HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e3.4 Seconds (LD Mode)\u003cbr\u003e5 Seconds (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e1.4% (LD Mode)\u003cbr\u003e2% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e14.3 lbs\u003cbr\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e8.66\"\u003cbr\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e7.72\"\u003cbr\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.37\"\u003cbr\u003e238 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303649373,"sku":"FRN015G1S-4U","price":1121.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/DH3FO2I6525RON50.jpg?v=1766444206"},{"product_id":"frn020g1s-4u-fuji-frenic-mega-20hp-inverter-variable-frequency-drive-460vac","title":"FRN020G1S-4U Fuji FRENIC-MEGA 20HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN020G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e20 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e30.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e12.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input (LD Mode)\u003cbr\u003e20 HP with 3-Phase Input (LD Mode)\u003cbr\u003e7.5 HP with Single Phase Input (HD Mode)\u003cbr\u003e15 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e14 kVA with Single Phase Input (LD Mode)\u003cbr\u003e24 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e10 kVA with Single Phase Input (HD Mode)\u003cbr\u003e20 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e17 Amps with Single Phase Input (LD Mode)\u003cbr\u003e30.5 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e13 Amps with Single Phase Input (HD Mode)\u003cbr\u003e24.5 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e43.8\/33 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e38\/28.6 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e28.6\/21.5 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e25.1\/18.8 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e13\/9.9 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e20\/15 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e15% (LD Mode)\u003cbr\u003e20% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e12.8 lbs\u003cbr\u003e5.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e8.66\"\u003cbr\u003e220 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e7.72\"\u003cbr\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.37\"\u003cbr\u003e238 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303714909,"sku":"FRN020G1S-4U","price":1366.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P3MC3FJ6525RON50.jpg?v=1766444210"},{"product_id":"frn025g1s-4u-fuji-frenic-mega-25hp-inverter-variable-frequency-drive-460vac","title":"FRN025G1S-4U Fuji FRENIC-MEGA 25HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN025G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e37 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e20.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e25 HP with 3-Phase Input (LD Mode)\u003cbr\u003e20 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e16 kVA with Single Phase Input (LD Mode)\u003cbr\u003e29 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e14 kVA with Single Phase Input (HD Mode)\u003cbr\u003e25 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e20 Amps with Single Phase Input (LD Mode)\u003cbr\u003e37 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e17 Amps with Single Phase Input (HD Mode)\u003cbr\u003e32 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e52.3\/43.8 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e45.4\/38 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e34.6\/29 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e31.3\/25 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e16\/13 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e25\/20 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e15% (LD Mode)\u003cbr\u003e20% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e20.9 lbs\u003cbr\u003e9.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e9.84\"\u003cbr\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e8.9\"\u003cbr\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e15.75\"\u003cbr\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e14.88\"\u003cbr\u003e378 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303780445,"sku":"FRN025G1S-4U","price":1836.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5M8AERK6525RON50.jpg?v=1766444208"},{"product_id":"frn030g1s-4u-fuji-frenic-mega-30hp-inverter-variable-frequency-drive-460vac","title":"FRN030G1S-4U Fuji FRENIC-MEGA 30HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN030G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e45 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e20.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e15 HP with Single Phase Input (LD Mode)\u003cbr\u003e30 HP with 3-Phase Input (LD Mode)\u003cbr\u003e10 HP with Single Phase Input (HD Mode)\u003cbr\u003e25 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e18 kVA with Single Phase Input (LD Mode)\u003cbr\u003e36 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e16 kVA with Single Phase Input (HD Mode)\u003cbr\u003e31 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e23 Amps with Single Phase Input (LD Mode)\u003cbr\u003e45 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e20 Amps with Single Phase Input (HD Mode)\u003cbr\u003e39 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e60.6\/52.3 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e52.6\/45.4 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e40\/34.5 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e36.3\/31 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e18\/16 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e29\/25 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e15% (LD Mode)\u003cbr\u003e20% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e20.9 lbs\u003cbr\u003e9.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e9.84\"\u003cbr\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e8.9\"\u003cbr\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e15.75\"\u003cbr\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e14.88\"\u003cbr\u003e378 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303878749,"sku":"FRN030G1S-4U","price":2448.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HTOANSL6525RON50.jpg?v=1766444210"},{"product_id":"frn040g1s-4u-fuji-frenic-mega-40hp-inverter-variable-frequency-drive-460vac","title":"FRN040G1S-4U Fuji FRENIC-MEGA 40HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN040G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e40 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e60 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e20 HP with Single Phase Input (LD Mode)\u003cbr\u003e40 HP with 3-Phase Input (LD Mode)\u003cbr\u003e15 HP with Single Phase Input (HD Mode)\u003cbr\u003e30 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e23 kVA with Single Phase Input (LD Mode)\u003cbr\u003e48 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e18 kVA with Single Phase Input (HD Mode)\u003cbr\u003e36 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e29 Amps with Single Phase Input (LD Mode)\u003cbr\u003e60 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e23 Amps with Single Phase Input (HD Mode)\u003cbr\u003e45 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e77.9\/60.6 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e67.7\/52.6 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e53.4\/41.6 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e50.2\/36 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e25\/19 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e40\/29 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e15% (LD Mode)\u003cbr\u003e20% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003cbr\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e9.84\"\u003cbr\u003e250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e8.9\"\u003cbr\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e15.75\"\u003cbr\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e14.88\"\u003cbr\u003e378 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.43\"\u003cbr\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e7.68\"\u003cbr\u003e195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.13\"\u003cbr\u003e105 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e3.54\"\u003cbr\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915303944285,"sku":"FRN040G1S-4U","price":2795.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T58229N6525RON50.jpg?v=1766444211"},{"product_id":"frn050g1s-4u-fuji-frenic-mega-50hp-inverter-variable-frequency-drive-460vac","title":"FRN050G1S-4U Fuji FRENIC-MEGA 50HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN050G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e50 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e75 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e55.1 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e25 HP with Single Phase Input (LD Mode)\u003cbr\u003e50 HP with 3-Phase Input (LD Mode)\u003cbr\u003e20 HP with Single Phase Input (HD Mode)\u003cbr\u003e40 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e30 kVA with Single Phase Input (LD Mode)\u003cbr\u003e60 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e24 kVA with Single Phase Input (HD Mode)\u003cbr\u003e48 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e37 Amps with Single Phase Input (LD Mode)\u003cbr\u003e75 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e30 Amps with Single Phase Input (HD Mode)\u003cbr\u003e60 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e94.3\/77.9 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e82\/67.7 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e69.1\/57.1 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e60.2\/50 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e32\/26 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e48\/40 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e55.1 lbs\u003cbr\u003e25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e12.6\"\u003cbr\u003e320 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e9.45\"\u003cbr\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e21.65\"\u003cbr\u003e550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.47\"\u003cbr\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e10.04\"\u003cbr\u003e255 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.53\"\u003cbr\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e5.51\"\u003cbr\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304009821,"sku":"FRN050G1S-4U","price":3284.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PFUSF0P6525RON50.jpg?v=1766444212"},{"product_id":"frn060g1s-4u-fuji-frenic-mega-60hp-inverter-variable-frequency-drive-460vac","title":"FRN060G1S-4U Fuji FRENIC-MEGA 60HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN060G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e60 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e91 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e57.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e30 HP with Single Phase Input (LD Mode)\u003cbr\u003e60 HP with 3-Phase Input (LD Mode)\u003cbr\u003e25 HP with Single Phase Input (HD Mode)\u003cbr\u003e50 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e37 kVA with Single Phase Input (LD Mode)\u003cbr\u003e30 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e73 kVA with Single Phase Input (HD Mode)\u003cbr\u003e60 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e46 Amps with Single Phase Input (LD Mode)\u003cbr\u003e38 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e91 Amps with Single Phase Input (HD Mode)\u003cbr\u003e75 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e114\/94.3 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e99.1\/82 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e84.3\/69.7 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e72.7\/60 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e39\/32 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e58\/48 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e57.3 lbs\u003cbr\u003e26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e12.6\"\u003cbr\u003e320 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e9.45\"\u003cbr\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e21.65\"\u003cbr\u003e550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.47\"\u003cbr\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e10.04\"\u003cbr\u003e255 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.53\"\u003cbr\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e5.51\"\u003cbr\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304108125,"sku":"FRN060G1S-4U","price":4005.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5MN6RCQ6525RON50.jpg?v=1766444213"},{"product_id":"frn075g1s-4u-fuji-frenic-mega-75hp-inverter-variable-frequency-drive-460vac","title":"FRN075G1S-4U Fuji FRENIC-MEGA 75HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN075G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e112 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e68.3 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e30 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e75 HP with 3-Phase Input (LD Mode)\u003cbr\u003e60 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e43 kVA with Single Phase Input (LD Mode)\u003cbr\u003e89 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e36 kVA with Single Phase Input (HD Mode)\u003cbr\u003e73 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e54 Amps with Single Phase Input (LD Mode)\u003cbr\u003e112 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e45 Amps with Single Phase Input (HD Mode)\u003cbr\u003e91 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e134\/114 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e121\/99.1 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e99.7\/84.5 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e89.1\/72 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e46\/39 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e71\/58 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e68.3 lbs\u003cbr\u003e31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e13.98\"\u003cbr\u003e355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e10.83\"\u003cbr\u003e275 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e24.21\"\u003cbr\u003e615 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e23.43\"\u003cbr\u003e595 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.47\"\u003cbr\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e10.63\"\u003cbr\u003e270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.53\"\u003cbr\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e6.1\"\u003cbr\u003e155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304173661,"sku":"FRN075G1S-4U","price":4466.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1OS86PR6525RON50.jpg?v=1766444216"},{"product_id":"frn1000g1s-4u-fuji-1000hp-frenic-mega-inverter-variable-frequecy-drive-460vac","title":"FRN1000G1S-4U Fuji 1000HP FRENIC-MEGA Inverter\/Variable Frequecy Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN1000G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1000 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e1370 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1170 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e400\/-\/300 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e1000\/-\/900 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e461\/-\/373 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e1092\/-\/932 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e579\/-\/469 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e1370\/-\/1170 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e1060\/-\/892 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e1093\/-\/970 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e488\/-\/410 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e871\/-\/773 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e1170 lbs\u003cbr\u003e530 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.81\"\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e61.02\"\u003cbr\u003e1550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e59.84\"\u003cbr\u003e1520 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e19.69\"\u003cbr\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e12.33\"\u003cbr\u003e313.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.35\"\u003cbr\u003e186.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304206429,"sku":"FRN1000G1S-4U","price":62555.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FEEOBFS6525RON50.jpg?v=1766444214"},{"product_id":"frn100g1s-4u-fuji-frenic-mega-100hp-inverter-variable-frequency-drive-460vac","title":"FRN100G1S-4U Fuji FRENIC-MEGA 100HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN100G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e100 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e150 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e72.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e40 HP with Single Phase Input (LD Mode)\u003cbr\u003e100 HP with 3-Phase Input (LD Mode)\u003cbr\u003e30 HP with Single Phase Input (HD Mode)\u003cbr\u003e75 HP with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e47 kVA with Single Phase Input (LD Mode)\u003cbr\u003e120 kVA with 3-Phase Input (LD Mode)\u003cbr\u003e44 kVA with Single Phase Input (HD Mode)\u003cbr\u003e89 kVA with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e59 Amps with Single Phase Input (LD Mode)\u003cbr\u003e150 Amps with 3-Phase Input (LD Mode)\u003cbr\u003e55 Amps with Single Phase Input (HD Mode)\u003cbr\u003e112 Amps with 3-Phase Input (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e110\/106 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e120\/89 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e51\/49 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e96\/71 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eAs Standard, Seperate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e72.8 lbs\u003cbr\u003e33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e13.98\"\u003cbr\u003e355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e10.83\"\u003cbr\u003e275 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e26.57\"\u003cbr\u003e675 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e25.79\"\u003cbr\u003e655 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.47\"\u003cbr\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e10.63\"\u003cbr\u003e270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.53\"\u003cbr\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e6.1\"\u003cbr\u003e155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304271965,"sku":"FRN100G1S-4U","price":5582.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RKB2P6U6525RON50.jpg?v=1766444216"},{"product_id":"frn125g1s-4u-fuji-125hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN125G1S-4U Fuji 125HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN125G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e125 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e176 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e93 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e50\/-\/40 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e125\/-\/100 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e55\/-\/48 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e140\/-\/120 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e70\/-\/61 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e176\/-\/150 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e132\/-\/113 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e143\/-\/120 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e61\/-\/53 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e114\/-\/96 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e93 lbs\u003cbr\u003e42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e13.98\"\u003cbr\u003e355 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e10.83\"\u003cbr\u003e275 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e29.13\"\u003cbr\u003e740 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e28.35\"\u003cbr\u003e720 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.47\"\u003cbr\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e10.63\"\u003cbr\u003e270 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.53\"\u003cbr\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e6.1\"\u003cbr\u003e155 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.39\"\u003cbr\u003e10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304337501,"sku":"FRN125G1S-4U","price":6686.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NMG44JV6525RON50.jpg?v=1766444217"},{"product_id":"frn150g1s-4u-fuji-150hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN150G1S-4U Fuji 150HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN150G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e150 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e210 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e137 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e50\/-\/50 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e150\/150\/125 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e65\/-\/57 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e167\/167\/140 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e99\/-\/72 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e253\/210\/176 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e158\/-\/137 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e175\/175\/143 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e73\/-\/63 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e137 lbs\u003cbr\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e16.93\"\u003cbr\u003e430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e38.19\"\u003cbr\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e14.17\"\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304403037,"sku":"FRN150G1S-4U","price":8143.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JOH6DK07525RON50.jpg?v=1766444218"},{"product_id":"frn200g1s-4u-fuji-200hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN200G1S-4U Fuji 200HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN200G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e200 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e 253Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e141 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e60\/-\/60 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e200\/200\/150 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e78\/-\/68 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e202\/202\/167 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e99\/-\/86 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e253\/253\/210 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e188\/-\/164 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e207\/207\/176 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e87\/-\/76 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e165\/165\/140 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e141 lbs\u003cbr\u003e64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e16.93\"\u003cbr\u003e430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e29.13\"\u003cbr\u003e740 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e27.95\"\u003cbr\u003e710 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e12.4\"\u003cbr\u003e315 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e5.31\"\u003cbr\u003e135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304435805,"sku":"FRN200G1S-4U","price":10764.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1BVQN027525RON50.jpg?v=1766444218"},{"product_id":"frn250g1s-4u-fuji-250hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN250G1S-4U Fuji 250HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN250G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e250 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e304 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e207 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e75\/-\/60 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e250\/250\/200 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e96\/-\/82 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e242\/242\/202 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e121\/-\/103 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e304\/304\/253 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e226\/-\/192 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e249\/249\/207 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e105\/-\/89 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e199\/199\/165 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e207 lbs\u003cbr\u003e94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e16.93\"\u003cbr\u003e430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e38.19\"\u003cbr\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e14.17\"\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304468573,"sku":"FRN250G1S-4U","price":12451.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V3J40237525RON50.jpg?v=1766444219"},{"product_id":"frn300g1s-4u-fuji-300hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN300G1S-4U Fuji 300HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN300G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e300 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e377 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e216 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e100\/-\/75 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e300\/300\/250 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e116\/-\/97 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e300\/300\/242 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e146\/-\/122 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e377\/377\/304 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e283\/-\/234 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e311\/311\/250 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e130\/-\/108 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e248\/24\/199 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e216 lbs\u003cbr\u003e98 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e20.87\"\u003cbr\u003e530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e16.93\"\u003cbr\u003e430 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e38.19\"\u003cbr\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e14.17\"\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304501341,"sku":"FRN300G1S-4U","price":15276.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T75B8347525RON50.jpg?v=1766444219"},{"product_id":"frn350g1s-4u-fuji-350hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN350G1S-4U Fuji 350HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN350G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e350 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e415 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e284 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e100\/-\/100 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e350\/350\/300 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e128\/-\/118 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e331\/331\/300 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e161\/-\/149 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e415\/415\/377 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e309\/-\/286 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e340\/340\/311 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e143\/-\/132 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e271\/271\/248 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e284 lbs\u003cbr\u003e129 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e26.77\"\u003cbr\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.42\"\u003cbr\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e38.19\"\u003cbr\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e14.17\"\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304534109,"sku":"FRN350G1S-4U","price":16739.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RO7SDP47525RON50.jpg?v=1766444220"},{"product_id":"frn450g1s-4u-fuji-450hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN450G1S-4U Fuji 450HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN450G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e450 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e520 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e309 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e125\/-\/100 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e450\/350\/350 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e160\/-\/133 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e414\/373\/330 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e202\/-\/167 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e520\/468\/415 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e392\/-\/319 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e435\/386\/340 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e181\/-\/147 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e347\/308\/271 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e309 lbs\u003cbr\u003e140 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e26.77\"\u003cbr\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.42\"\u003cbr\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e38.19\"\u003cbr\u003e970 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e14.17\"\u003cbr\u003e360 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.16\"\u003cbr\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304566877,"sku":"FRN450G1S-4U","price":18748.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PV67JF57525RON50.jpg?v=1766444221"},{"product_id":"frn500g1s-4u-fuji-500hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN500G1S-4U Fuji 500HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN500G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e500 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e650 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e540 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e150\/-\/125 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e500\/450\/400 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e198\/-\/162 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e518\/466\/414 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e250\/-\/204 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e650\/585\/520 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e492\/-\/395 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e547\/486\/436 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e227\/-\/182 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e436\/388\/347 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e540 lbs\u003cbr\u003e245 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e26.77\"\u003cbr\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.42\"\u003cbr\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e55.12\"\u003cbr\u003e1400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e53.94\"\u003cbr\u003e1370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e17.32\"\u003cbr\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304599645,"sku":"FRN500G1S-4U","price":27485.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/N5BRO567525RON50.jpg?v=1766444220"},{"product_id":"frn600g1s-4u-fuji-600hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN600G1S-4U Fuji 600HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN600G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e600 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e740 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e540 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e200\/-\/150 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e600\/500\/450 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e229\/-\/184 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e590\/518\/466 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e288\/-\/231 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e740\/650\/585 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e558\/-\/446 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e613\/547\/487 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e257\/-\/206 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e489\/436\/388 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e540 lbs\u003cbr\u003e245 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e26.77\"\u003cbr\u003e680 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.42\"\u003cbr\u003e290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e55.12\"\u003cbr\u003e1400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e53.94\"\u003cbr\u003e1370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e17.32\"\u003cbr\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304632413,"sku":"FRN600G1S-4U","price":31943.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5SSAUR67525RON50.jpg?v=1766444222"},{"product_id":"frn700g1s-4u-fuji-700hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN700G1S-4U Fuji 700HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN700G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e700 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e840 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e805 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e200\/-\/150 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e700\/600\/500 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e259\/-\/206 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e669\/590\/518 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e326\/-\/259 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e840\/740\/650 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e633\/-\/512 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e686\/613\/547 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e291\/-\/236 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e547\/489\/436 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e805 lbs\u003cbr\u003e365 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e34.65\"\u003cbr\u003e880 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e55.12\"\u003cbr\u003e1400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e53.94\"\u003cbr\u003e1370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e17.32\"\u003cbr\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304665181,"sku":"FRN700G1S-4U","price":37100.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3DVR3I77525RON50.jpg?v=1766444222"},{"product_id":"frn800g1s-4u-fuji-800hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN800G1S-4U Fuji 800HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN800G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e800 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e960 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e805 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e250\/-\/200 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e800\/700\/600 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e305\/-\/236 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e765\/669\/590 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e384\/-\/297 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e960\/840\/740 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e717\/-\/575 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e766\/686\/614 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e330\/-\/265 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e611\/547\/489 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e805 lbs\u003cbr\u003e365 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e34.65\"\u003cbr\u003e880 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e55.12\"\u003cbr\u003e1400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e53.94\"\u003cbr\u003e1370 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e17.32\"\u003cbr\u003e440 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.09\"\u003cbr\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304697949,"sku":"FRN800G1S-4U","price":45923.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HEF89887525RON50.jpg?v=1766444223"},{"product_id":"frn900g1s-4u-fuji-900hp-frenic-mega-inverter-variable-frequency-drive-460vac","title":"FRN900G1S-4U Fuji 900HP FRENIC-MEGA Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN900G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e900 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e1170 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1170 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e300\/-\/250 HP with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e900\/-\/800 HP with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e368\/-\/305 kVA with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e932\/-\/765 kVA with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e579\/-\/384 Amps with Single Phase Input (LD\/MD\/HD Mode)\u003cbr\u003e1170\/-\/960 Amps with 3-Phase Input (LD\/MD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 120% for 1 Minute\u003cbr\u003eMD Mode: 150% for 1 Minute\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e878\/-\/707 Amps (Single Phase Input with DCR, LD\/MD\/HD)\u003cbr\u003e970\/-\/767 Amps (3 Phase Input with DCR, LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e404\/-\/325 kVA with Single Phase Input with DCR (LD\/MD\/HD)\u003cbr\u003e773\/-\/611 kVA with 3-Phase Input and DCR (LD\/MD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e7 to 12% (LD\/MD Mode)\u003cbr\u003e10 to 15% (HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard, Separate Component.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e1170 lbs\u003cbr\u003e530 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e39.37\"\u003cbr\u003e1000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e11.81\"\u003cbr\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e61.02\"\u003cbr\u003e1550 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e59.84\"\u003cbr\u003e1520 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.61\"\u003cbr\u003e15.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e19.69\"\u003cbr\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e12.33\"\u003cbr\u003e313.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e7.35\"\u003cbr\u003e186.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.25\"\u003cbr\u003e6.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.59\"\u003cbr\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304730717,"sku":"FRN900G1S-4U","price":57972.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/VE4UEU87525RON50.jpg?v=1766444223"},{"product_id":"frnf50g1s-4u-fuji-frenic-mega-1-2hp-inverter-variable-frequency-drive-460vac","title":"FRNF50G1S-4U Fuji FRENIC-MEGA 1\/2HP Inverter\/Variable Frequency Drive, 460VAC","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e drive series are high performance, multifunctional inverters providing the industry’s highest performance for three-phase motor applications. They offer expanded power ratings and flexible configurations that support 1\/2 HP through 1000 HP motors. They are designed for 24\/7 operation with embedded motor protection and critical maintenance functions.\u003c\/p\u003e\n\u003cp\u003eFuji Electric's \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e continues to provide the highest level of quality, robust design, easy to use interface, and competitive price for general-purpose industrial drives. Additionally the \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series offers more high-performance features and functions that are typically only found on “high-end” drives allowing one product family to cover a broader range of applications.\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003eFRENIC-MEGA\u003c\/b\u003e series includes a common interface, common programming and industrial network connectivity and is exceptionally suited for industrial applications where standardizing on one product across a facility can lead to increased productivity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRNF50G1S-4U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480 VAC\u003cbr\u003e50\/60Hz\u003cbr\u003eSingle or Three Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd\u003e380-480 VAC\u003cbr\u003eThree Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e1.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e3.8 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003cb\u003eOutput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1\/4 HP with Single Phase Input (LD\/HD Mode)\u003cbr\u003e1\/2 HP with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e0.8 kVA with Single Phase Input (LD\/HD Mode)\u003cbr\u003e1.2 kVA with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e0.9 Amps with Single Phase Input (LD\/HD Mode)\u003cbr\u003e1.5 Amps with 3-Phase Input (LD\/HD Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 380-480VAC (with AVR function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003eLD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003eHD Mode: 150% for 1 Minute, 200% for 3 Seconds\u003cbr\u003e(Overload capability interval: IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003eV\/F, Dynamic Torque Vector Control: 0-500Hz (HD Mode) or 0-120Hz (MD\/LD Mode)\u003cbr\u003eSensorless Vector Control: 0-120Hz\u003cbr\u003eClosed Loop Vector Control: 0-200Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eInput Ratings:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Voltage\u003c\/th\u003e\n\u003ctd\u003e380 to 480VAC +10%\/-15%\u003cinterphase voltage unbalance:\u003e\u003c\/interphase\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e1.7 Amps (Single Phase Input, LD\/HD)\u003cbr\u003e1.4 Amps (3 Phase Input, LD\/HD)\u003cbr\u003e1.0 Amps (Single Phase Input with DCR, LD\/HD)\u003cbr\u003e0.7 Amps (3 Phase Input with DCR, LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e0.5 kVA with Single Phase Input with DCR (LD\/HD)\u003cbr\u003e0.6 kVA with 3-Phase Input and DCR (LD\/HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eBraking:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e150%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Transistor\u003c\/th\u003e\n\u003ctd\u003e-Built-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Resistor\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Time\u003c\/th\u003e\n\u003ctd\u003e5 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eED\u003c\/th\u003e\n\u003ctd\u003e5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\u003cb\u003eOther:\u003c\/b\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003eMulti-function Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Standards\u003c\/th\u003e\n\u003ctd\u003eUL508C, C22.2 No.14, EN61800-5-1:2007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP20, UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eNatural Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e3.8 lbs\u003cbr\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 65°C (-13 to 149°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eEN ISO13849-1, EN954-1, Category 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eUL, cUL: UL508C, C22.2 No. 14, EN61800-5:2007\u003cbr\u003eCE: EN61800-5-1\u003cbr\u003eRoHS: 2002\/96\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (Dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e56 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10VDC or 4 to 20mA\u003cbr\u003eCan be Configured to Provide Output Signal Proportional to 15 Different Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24VDC Output Terminal Rated 100mA \u003c\/li\u003e\n\u003cli\u003eHigh Performance LED \u0026amp; LCD Keypad with NEMA\/UL Type 4 Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating and Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eHeatsink can be mounted through the back of an enclosed design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eMotor Control\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eMultiple Power Ratings:\u003cbr\u003e  LD (Low Duty): 120% for 1 Min\u003cbr\u003e  MD (Medium Duty): 150% for 1 Min \u003cbr\u003e  HD (High Duty): 200% for 3s \/ 150% for 1 Min \u003c\/li\u003e\n\u003cli\u003eHigh Performance Closed Loop Vector Control with Option Card \u003c\/li\u003e\n\u003cli\u003eHigh Performance Sensor-less Vector Control \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Transistor Up to 40HP(LD)\/30HP(HD) \u003c\/li\u003e\n\u003cli\u003eBuilt-in Braking Resistor up to 15HP(LD)\/10HP(HD) \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input for All Models \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input Compliant with EN ISO13849-1, EN954-1, Category 3\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS Directive Compliance\u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type 1 by Option Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Expansion Options:\u003c\/b\u003e\u003cli\u003eEthernet (OPC-ETH)\u003c\/li\u003e\n\u003cli\u003eCC-Link (OPC-G1-CCL)\u003c\/li\u003e\n\u003cli\u003eDeviceNet (OPC-G1-DEV)\u003c\/li\u003e\n\u003cli\u003eProfibus DP (OPC-G1-PDP\/OPC-G1-PDP2)\u003c\/li\u003e\n\u003cli\u003eCANopen (OPC-G1-COP)\u003c\/li\u003e\n\u003cli\u003eT-Link (OPC-G1-TL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion Options:\u003c\/b\u003e\u003cli\u003eKeypad with USB Port (TP-E1U)\u003c\/li\u003e\n\u003cli\u003eRelay Output (OPC-G1-RY)\u003c\/li\u003e\n\u003cli\u003eDigital Inputs (OPC-G1-DI)\u003c\/li\u003e\n\u003cli\u003eDigital Outputs (OPC-G1-DO)\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs (OPC-G1-AIO)\u003c\/li\u003e\n\u003cli\u003ePG (Encoder) (OPC-G1-PG 12V \/ OPC-G1-PG2 5V)\u003c\/li\u003e\n\u003cli\u003ePG Synchronization (OPC-G1-PG22)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eOther Expansion Options:\u003c\/b\u003e\u003cli\u003eDC\/AC Reactor \u003c\/li\u003e\n\u003cli\u003eCE Filter \u003c\/li\u003e\n\u003cli\u003eBraking Unit \u003c\/li\u003e\n\u003cli\u003eBraking Resistor \u003c\/li\u003e\n\u003cli\u003eNEMA\/UL Type1 Kit \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e4.33\"\u003cbr\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e3.78\"\u003cbr\u003e96 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e10.24\"\u003cbr\u003e260 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e9.69\"\u003cbr\u003e246 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e0.28\"\u003cbr\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e5.2\"\u003cbr\u003e132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e4.45\"\u003cbr\u003e113 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e0.75\"\u003cbr\u003e19 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD3\u003c\/th\u003e\n\u003ctd\u003e0.12\"\u003cbr\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eøA\u003c\/th\u003e\n\u003ctd\u003e0.24\"\u003cbr\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cbr\u003e\u003cb\u003eManuals \u0026amp; Specifications:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Quick_Start_Guide-FECA-MEGAQRG.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Quick Reference Guide (PDF, 2 pages, 1.61MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_MEGA_Brochure.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Brochure (PDF, 4 pages, 1.62MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-MEGA-Datasheet-FEA-ACDR-DS-105.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Datasheet (PDF, 2 pages, 1.84MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_General_Spec_FECA-TE-120.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA General Specifications (PDF, 22 pages, 633KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"hhttps:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_INR-SI47-1457a-E_1fafc46c-110b-4930-b599-5324341f971f.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Instruction Manual (PDF, 358 pages, 6.54MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_User_s_Manual_MEHT536b.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA User Manual (PDF, 680 pages, 21.3MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FrenicMEGA_Catalog_MEH535a.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Catalog (PDF, 52 pages, 6.75MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Efficiencies_FECA-TE-125.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Efficiency (PDF, 3 pages, 139KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Watts_Loss_FECA-TE-122A.pdf\" target=\"_blank\"\u003eFuji FRENIC-MEGA Drive Watts Loss (PDF, 1 page, 65KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eApplication Notes:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Auto_Restart_FECA-AN-139.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Automatic Restart after Power Failure (PDF, 2 pages, 67KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HOAwithPIDandPOT_FEAC-AN-159.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto with PID and a Potentiometer (PDF, 3 pages, 272KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Keypad_HOA_FECA-AN-144.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Hand-Off-Auto Switch Wiring Setup and Parameters (PDF, 2 pages, 54KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_PID_with_Transducer_FECA-AN-132A.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: PID Control with Pressure Transducer Wiring and Function Code Settings (PDF, 2 pages, 113KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_Pre-Set_Speed_FECA-AN-125.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Pre-Set Speed Operation Wiring and Function Codes (PDF, 2 pages, 74KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_RS-485_Converter_FECA-AN-128A_0.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: USB to RS-485 Converter Usage (PDF, 4 pages 429KB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MEGA_three-wire_start-stop_FECA-AN-122.pdf\" target=\"_blank\"\u003eFRENIC-MEGA Application Note: Three-Wire Start\/Stop Wiring and Function Codes (PDF, 1 page, 45KB)\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSoftware:\u003c\/b\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/The-USB-communication-driver-for-FRENIC-series-Loader-For-Windows-8_1_10.zip\" target=\"_blank\"\u003eUSB Communication Driver for Win 8.1\/10 (ZIP, 5.5MB)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-Mini_C1__Mini_C2__Eco_Multi_MEGA_Ace_Loader_Software_FRENIC_Loader_3_3_ver7_3_4_1a_For_U_S_A_9e749291-33e6-4346-a122-699124aa4a81.ZIP\" target=\"_blank\"\u003eFRENIC Loader 3.3 Version 7.3.4.1a EN (ZIP, 18.9MB)\u003c\/a\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManufacturer Information\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/vendorBranding\/fujele.css\"\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eIdeal for highly accurate control such as positioning\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003ePG vector control * This option card is sold separately.\u003c\/h5\u003e\n\u003cp\u003eEffective in providing highly accurate control for applications such as printing presses.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:1500\r\u003cbr\u003eSpeed response: 100Hz\r\u003cbr\u003eSpeed control accuracy: ±0.01%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\r\u003cbr\u003e* The above specifications may vary depending on the environment or conditions of use.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/001_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFuji’s original dynamic torque vector control has further evolved.\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eBesides the dynamic torque vector control, the inverter is equipped with the motor constant tuning for compensating even a voltage error of the main circuit devices and the magnetic flux observer of a new system. This allows a high starting torque of 200% even at a low-speed rotation of 0.3Hz.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/003_1426.png\" width=\"713\" h=\"\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved durability in overload operation\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter performs short-time acceleration and deceleration with the maximum capacity by extending the time specification of overload current ratings compared with our previous models. This improves the operation efficiency of cutting machines or conveyance equipment.\r\u003cbr\u003eOverload durability: 200% for 3 sec and 150% for 1 min.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpTextBlock01\"\u003e\u003cp\u003eThe standard model is available in two specifications concerning the operational load.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpDataTable01 partsMarginB_40\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eClassification\u003c\/th\u003e\n\u003cth\u003eOverload current rating\u003c\/th\u003e\n\u003cth\u003eMajor use\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHD (High duty) spec\u003c\/td\u003e\n\u003ctd\u003e200% for 3 sec, 150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under heavy load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMD (Middle duty) spec\u003c\/td\u003e\n\u003ctd\u003e150% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under constant torque load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLD (Low duty) spec\u003c\/td\u003e\n\u003ctd\u003e120% for 1 min\u003c\/td\u003e\n\u003ctd\u003eOperation under light load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eExpanded capacity for the braking circuit built-in type\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eA braking circuit is built in the 22kW or smaller models as a standard feature. These inverters are applicable to machines that use regenerative loads such as a vertical conveyance machinery.\r\u003cbr\u003e(7.5kW or smaller models also incorporate a braking resistor.)\r\u003cbr\u003e* Inverters with built-in braking circuit are available on request for 30kW to 160kW models in 400V series.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMaximizing the performance of a general-purpose motor\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eSpeed sensor-less vector control\u003c\/h5\u003e\n\u003cp\u003eUseful for the applications that require a high starting torque, such as a gondola type multi-level car parking tower.\u003c\/p\u003e\n\u003cdiv class=\"locgryabox\"\u003eSpeed control range: 1:200\r\u003cbr\u003eSpeed response: 20Hz\r\u003cbr\u003eSpeed control accuracy: ±0.5%\r\u003cbr\u003eCurrent response: 500Hz\r\u003cbr\u003eTorque accuracy: ±10%\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/002_710.jpg\" width=\"170\" height=\"226\" alt=\"\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eImproved reaction to the fluctuation of impact load\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eWhen a load fluctuation occurs, the inverter can provide a torque response in the class-top level. It controls the flux to minimize the fluctuation in the motor speed while suppressing the vibration. This function is best suited for the equipment that requires stable speed such as a cutting machine.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/004_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eQuicker response to the operation commands\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe terminal response to the operation commands has had an established reputation. FRENIC-MEGA has further shortened this response time, achieving the industry's top response time.\r\u003cbr\u003eThis function is effective in shortening the tact time per cycle in processes which include frequent repetitions.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/005_1426.png\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eConvenient function for operations at the specified speed\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eThe pulse train input function is equipped as standard.\u003c\/h5\u003e\n\u003cp\u003eIt is possible to issue the speed command with the pulse train input (single-phase pulse and a sign of command value) from the pulse generator, etc. (Maximum pulse input frequency: 100kHz)\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/006_710_a649f586-0267-4370-bfef-aaa045abff4e.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\n\u003ch5\u003eRatio operation\u003c\/h5\u003e\n\u003cp\u003eThe ratio operation is the function particularly convenient for adjusting two or more conveyance systems. The ratio of the main axis speed to the two or more trailing axes can be set as a frequency command. On the machine that handles load variation such as a conveyance machine, the conveyance speed can be adjusted easily.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/008_710_ca249151-5b82-47ae-b80a-86fddfb4641b.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eThorough protection of the braking circuit\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e\u003cp\u003eThe inverter protects the braking resistor by monitoring the braking transistor operation. The inverter outputs a dedicated signal for the detection of the braking transistor failure. A circuit for shutting off the input power supply must be provided outside of the inverter. When this signal is output, the power is shut off; thus protecting the braking circuit.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eOptimum function for preventing an object from slipping down\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTwoColBlock02 partsMarginB_40\"\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cp\u003eThe reliability of the brake signal was increased for uses such as vertical conveyance.\r\u003cbr\u003eConventionally, the current and frequency values have been monitored when the brake signal is output. By adding a torque value to these two values, the brake timing can be adjusted more easily.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv class=\"smpCategoryUnit\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/007_710.jpg\" width=\"344\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDancer control function optimum for winding control\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe PID value, calculated by comparing the target value and the feedback value, is added to or subtracted from the reference speed. Since the PID calculator gain (in proportional range) can be set to a low value, the inverter can be applied to the automatic control system that requires quick response such as a speed controller.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/009_1426.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eMore functions are available to meet various requirements\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_20\"\u003e(1) Analog inputs: voltage input through 2 terminals with polarity, current input through 1 terminal\r\u003cbr\u003e(2) Slow flowrate level stop function (Pressurized operation is possible before slow flowrate operation stop.)\r\u003cbr\u003e(3) Non-linear V\/f pattern at 3 points\r\u003cbr\u003e(4) Dummy failure output function\r\u003cbr\u003e(5) Selection of 4 motors\r\u003cbr\u003e(6) S-shape accel.\/decel. range setting\r\u003cbr\u003e(7) Detecting disconnection of the PID feedback\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eAdvanced network function\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003ch5\u003eRS-485 communications is possible as a standard function (terminal base).\u003c\/h5\u003e\n\u003cp\u003eBesides the port (RJ-45 connector) shared with the keypad, an additional RS-485 port is provided as a standard function. Since the interface is connected through the terminal strip, multi-drop connections can be easily made.\u003c\/p\u003e\n\u003cdiv class=\"alignC\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/019_1426_6e6502b8-7f50-4bbe-91bd-ddb621ac1140.jpg\" width=\"713\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eDesigned life 10 years\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe designed lives of the various consumable parts inside the inverter have been extended to 10 years, which also extends equipment maintenance cycles.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConsumable part\u003c\/th\u003e\n\u003cth\u003eDesigned life\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMain circuit capacitor\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrolytic capacitor on PCB\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling fan\u003c\/th\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"locgryabox\"\u003e\u003cp\u003e\u003cstrong\u003eThe conditions used for the calculation of the parts' life are:\u003c\/strong\u003e an ambient air temperature of 40°C and under the load rate of 100% (HD spec) or 80% (LD spec) * The design life is a calculated value and is not guaranteed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eFull support of life warnings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\n\u003cp\u003eThe inverter is equipped with the functions for facilitating the maintenance of the equipment.\u003c\/p\u003e\n\u003cdiv class=\"smpDataTableScroll03 partsMarginB_40\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eCumulative inverter run time (h)\u003c\/th\u003e\n\u003ctd\u003eDisplays the total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inverter startups\u003c\/th\u003e\n\u003ctd\u003eDisplays the number of times the inverter has started the equipment.\r\u003cbr\u003e\u003cbr\u003eExample of use:\r\u003cbr\u003eThis data indicates the time to replace the equipment parts (such as a timing belt) operating under the normal load.\r\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEquipment maintenance warning Cumulative run time (h) Number of startups\u003c\/th\u003e\n\u003ctd\u003eBy inputting the signal for operation with the commercial power supply, the time without the inverter operation time can also be measured.\r\u003cbr\u003eThis makes it possible to manage the total run time of the equipment and the number of startups. Such data is usable for preparing the maintenance schedule.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay of inverter life warning\u003c\/th\u003e\n\u003ctd\u003eThe displayed contents include:\r\u003cbr\u003emain circuit capacitor capacity, total run time of the cooling fan (with ON\/OFF compensation), total run time of the electrolytic capacitor on the printed circuit board, and total run time of the inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"scrollBtnOuter\" style=\"display: none;\"\u003e\u003ca href=\"javascript:void(0)\" class=\"smpBtnStyle01\"\u003e\u003cspan\u003eScroll\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 class=\"smpStyle_h4_01\"\u003e\u003cspan\u003eCompliance with RoHS Directives\u003c\/span\u003e\u003c\/h4\u003e\n\u003cdiv class=\"smpTextBlock01 partsMarginB_40\"\u003e\u003cp\u003eMEGA complies with European regulations that limit the use of specific hazardous substances (RoHS) as a standard. This inverter is environment-friendly as the use of the following six hazardous substances are restricted: Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated biphenyl ether (PBDE)\r\u003cbr\u003e\u003cbr\u003eAbout RoHS:\r\u003cbr\u003eThe Directive 2011\/65\/EU, promulgated by the European Parliament and European Council, limits the use of specific hazardous substances included in electrical and electronic devices.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915304796253,"sku":"FRNF50G1S-4U","price":480.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BF81BDC7525RON50.jpg?v=1766444225"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/QSKHF50T4SS1ANB0.jpg?v=1766430954","url":"https:\/\/witmermotor.com\/collections\/380-480vac.oembed","provider":"Witmer Motor Service","version":"1.0","type":"link"}