{"title":"3 Phase Explosion Proof","description":"","products":[{"product_id":"00158xt3e145tc-weg-1-5hp-explosion-proof-electric-motor-1800rpm","title":"00158XT3E145TC WEG 1.5HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet\"\u003e\n\u003cul class=\"nav nav-pills product-techspecs-tabs\" role=\"tablist\"\u003e\n\u003cli role=\"presentation\" class=\"active\"\u003e\u003ca href=\"#datasheet-0\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e208-230\/460 V 60 Hz 4P \u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e\u003ca href=\"#datasheet-1\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e380 V 50 Hz 4P IE2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e\u003ca href=\"#datasheet-2\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e400 V 50 Hz 4P IE2\u003c\/a\u003e\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e\u003ca href=\"#datasheet-3\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e415 V 50 Hz 4P IE3\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1760 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.22 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e4.53-4.10\/2.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e40.4-36.5\/18.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e8.9x(Code L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e2.28-2.64\/1.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e4.42 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e350 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e25s (cold) 14s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e51.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e79.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r81.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r85.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r86.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.58 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.70 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.78 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1440 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e4.00 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e15.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.6x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.40 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e200 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e260 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e79.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1450 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e3.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e16.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.2x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.43 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.36 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e229 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e290 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e79.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.62 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.74 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.81 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1450 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e3.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.27 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e17.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.7x(Code K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.49 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.36 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e79.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r82.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r85.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.58 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.71 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.79 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"margin-top:0; margin-bottom:30px;\"\u003e\n\u003ch4 class=\"pb10\"\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\u003cdiv class=\"col-xs-12 col-sm-12\"\u003e\u003ctable class=\"table table-striped table-hover\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame Material\u003c\/th\u003e\n\u003ctd\u003eCast Iron \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpregnation Method\u003c\/th\u003e\n\u003ctd\u003eDip and Bake Polyester \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain terminal box hole\u003c\/th\u003e\n\u003ctd\u003eNPT 3\/4\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Block\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShaft Locking Device\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShaft Material\u003c\/th\u003e\n\u003ctd\u003eSAE 1040\/45 Carbon Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePainting\u003c\/th\u003e\n\u003ctd\u003eRAL 5009 202P (ISO 12944 - C4) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrounding Lugs\u003c\/th\u003e\n\u003ctd\u003eSingle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan Cover material\u003c\/th\u003e\n\u003ctd\u003eRolled Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTropicalized Painting\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan material\u003c\/th\u003e\n\u003ctd\u003ePlastic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBearing cap\u003c\/th\u003e\n\u003ctd\u003eYes- Bearing Cap \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Material\u003c\/th\u003e\n\u003ctd\u003eCarbon Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWinding thermal protection\u003c\/th\u003e\n\u003ctd\u003eThermostat - 2 wires 1 per phase 155°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBalancing Method\u003c\/th\u003e\n\u003ctd\u003e1\/2 Key \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrip Cover\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915169857629,"sku":"00158XT3E145TC","price":993.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/ISJM8RBDP6QUF8U0.jpg?v=1766442326"},{"product_id":"00158xt3er145tc-weg-1-5hp-explosion-proof-electric-motor-1800rpm","title":"00158XT3ER145TC WEG 1.5HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e NEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e 208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e 1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e 1.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e Footless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e W-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e Left position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e IC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1760 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.22 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e4.53-4.10\/2.05 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e40.4-36.5\/18.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e8.9x(Code L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e2.28-2.64\/1.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e4.42 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e350 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e25s (cold) 14s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e51.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e73.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 81.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 85.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 86.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.58 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.70 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1440 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e4.00 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e15.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.6x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.40 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e200 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e260 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e73.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1450 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e3.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e16.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.2x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.43 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.36 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e229 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e290 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e73.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.62 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.74 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.81 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e1.5 HP (1.1 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1450 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e3.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e2.27 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e17.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.7x(Code K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.49 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.36 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e27s (cold) 15s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1303 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e73.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 82.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 85.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.58 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.71 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.79 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915169890397,"sku":"00158XT3ER145TC","price":1010.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/IN4O8RBDP6QUF8U0.jpg?v=1766442328"},{"product_id":"00218xt3e145tc-weg-2hp-explosion-proof-electric-motor-1800rpm","title":"00218XT3E145TC WEG 2HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e NEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e 208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e 1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e 2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e Foot-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e F-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e Left position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e IC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1750 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.78 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e6.02-5.58\/2.79 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e53.5-49.7\/24.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e8.9x(Code L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e2.76-3.20\/1.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e5.92 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e19s (cold) 11s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1595 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e51.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e75.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 85.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 86.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.56 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.70 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1425 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e5.00 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e3.29 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e25.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.6x(Code K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e7.27 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e190 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e220 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1595 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e75.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 82.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.64 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1435 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e4.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e3.18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e24.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.8x(Code K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e1.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e7.22 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e220 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1595 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e75.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 82.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.59 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.73 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.81 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e143\/5TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e2 HP (1.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1445 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e3.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e3.18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e24.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.8x(Code K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e2.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e7.17 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e240 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e0.1595 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e49.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e75.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 82.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 84.0 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.55 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.69 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915169923165,"sku":"00218XT3E145TC","price":1021.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/KD6R8RBDP6QUF8U0.jpg?v=1766442328"},{"product_id":"00718xt3e213t-weg-7-5hp-explosion-proof-electric-motor-1800rpm","title":"00718XT3E213T WEG 7.5HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e NEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e 208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e 1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e 7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e Foot-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e Without\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e F-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e Left position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e IC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e213\/5T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e7.5 HP (5.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1765 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.94 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e20.8-18.8\/9.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e139-126\/63.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.7x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e6.90-8.00\/4.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e22.0 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e240 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e1.38 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e58.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e209 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 90.2 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 91.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 91.7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.60 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.73 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.80 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e213\/5T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e7.5 HP (5.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1460 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e11.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e61.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e5.5x(Code F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e4.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e26.6 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e170 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e200 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e1.38 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e56.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e209 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 88.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 89.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 89.5 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e213\/5T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e7.5 HP (5.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1460 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e10.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e68.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.4x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e4.40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e26.6 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e180 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e1.38 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e56.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e209 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 88.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 89.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 90.2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.63 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.75 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e213\/5T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e7.5 HP (5.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1465 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e10.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e72.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.8x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e4.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e26.5 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e210 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e21s (cold) 12s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e1.38 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e56.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e209 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 88.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 89.5 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 90.2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.61 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.73 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.80 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915170775133,"sku":"00718XT3E213T","price":1688.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/280HGSCDP6QUF8U0.jpg?v=1766442340"},{"product_id":"02518xt3er284tc-weg-25hp-explosion-proof-electric-motor-1800rpm","title":"02518XT3ER284TC WEG 25HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e NEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e 208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e 1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e 25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e Footless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e W-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e Left position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e IC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e284TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e25 HP (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1775 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.39 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e66.1-59.8\/29.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e542-490\/245 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e8.2x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e23.3-27.0\/13.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e73.0 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e4.54 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e68.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e484 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.6 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.67 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e284TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e25 HP (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1460 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e36.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e234 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.4x(Code G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e13.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e88.7 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e229 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e240 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e4.54 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e484 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 91.7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.72 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.81 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e284TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e25 HP (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1465 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e34.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e247 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.1x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e14.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e88.4 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e240 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e4.54 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e484 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.70 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.79 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e284TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e25 HP (18.5 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1465 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e34.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e258 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.6x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e15.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e88.4 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e260 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e270 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e4.54 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e484 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.68 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e \u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915173331037,"sku":"02518XT3ER284TC","price":3862.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/6BDKFMGDP6QUF8U0.jpg?v=1766442372"},{"product_id":"03018xt3er286tc-weg-30hp-explosion-proof-electric-motor-1800rpm","title":"03018XT3ER286TC WEG 30HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e NEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e 208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e 1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e 30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e Footless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e W-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e Left position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e IC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet\"\u003e\n\u003cul class=\"nav nav-pills product-techspecs-tabs\" role=\"tablist\"\u003e\n\u003cli role=\"presentation\" class=\"active\"\u003e \u003ca href=\"#datasheet-0\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e208-230\/460 V 60 Hz 4P \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#datasheet-1\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e380 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#datasheet-2\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e400 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#datasheet-3\" class=\"xtt-tab-resize-features\" role=\"tab\" data-toggle=\"tab\"\u003e415 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003ch4 class=\"pb10\"\u003eElectric Motors\u003c\/h4\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1775 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.39 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e79.6-72.0\/36.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e629-569\/284 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.9x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e25.0-29.0\/14.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e87.6 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e30s (cold) 17s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003cinput class=\"xtt-token hidden\" value=\"#{VAR_MOTOR.yforma_construtiva_mercado.desc}\" disabled\u003e\n\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e68.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e519 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.6 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1465 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e43.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e278 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.4x(Code G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e14.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e106 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e519 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of fullload.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 91.7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.71 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.80 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1470 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.00 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e41.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e298 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.2x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e15.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e106 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e519 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.68 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.78 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286TC\u003cinput class=\"xtt-tokenhidden\" value=\"#{VAR_MOTOR.ycarcaca_comercial}\" disabled\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1475 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e40.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e311 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.7x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e16.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e105 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e310 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e310 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eW-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e519 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e (1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e 0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e 0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr style=\"margin-top:0; margin-bottom:30px;\"\u003e\n\u003ch4 class=\"pb10\"\u003eFeatures\u003c\/h4\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\u003cdiv class=\"col-xs-12 col-sm-12\"\u003e\u003ctable class=\"table table-striped table-hover\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame Material\u003c\/th\u003e\n\u003ctd\u003eCast Iron \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpregnation Method\u003c\/th\u003e\n\u003ctd\u003eDip and Bake Polyester \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegreasing System\u003c\/th\u003e\n\u003ctd\u003eAt Drive end and Non-drive end \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain terminal box hole\u003c\/th\u003e\n\u003ctd\u003eNPT 1 1\/2\" \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Block\u003c\/th\u003e\n\u003ctd\u003eWithout \u003cinput class=\"xtt-token hidden\" value=\"#{VAR_COMPLEMENTO.ytipo_placa_borne}\" disabled\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShaft Locking Device\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrain\u003c\/th\u003e\n\u003ctd\u003eSinterized, Exd \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShaft Material\u003c\/th\u003e\n\u003ctd\u003eSAE 1040\/45 Carbon Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePainting\u003c\/th\u003e\n\u003ctd\u003eRAL 5009 202P (ISO 12944 - C4) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrounding Lugs\u003c\/th\u003e\n\u003ctd\u003eSingle \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan Cover material\u003c\/th\u003e\n\u003ctd\u003eCast Iron \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTropicalized Painting\u003c\/th\u003e\n\u003ctd\u003eWithout \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFan material\u003c\/th\u003e\n\u003ctd\u003ePlastic \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBearing cap\u003c\/th\u003e\n\u003ctd\u003eYes- Bearing Cap \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBolt Material\u003c\/th\u003e\n\u003ctd\u003eCarbon Steel \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWinding thermal protection\u003c\/th\u003e\n\u003ctd\u003eThermostat - 2 wires 1 per phase 155°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBalancing Method\u003c\/th\u003e\n\u003ctd\u003e1\/2 Key \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDrip Cover\u003c\/th\u003e\n\u003ctd\u003eWith \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"curve\"\u003e\n\u003cul class=\"nav nav-pills product-techspecs-tabs\" role=\"tablist\"\u003e\n\u003cli role=\"presentation\" class=\"active\"\u003e \u003ca href=\"#curve-0\" class=\"xtt-ajax-tab\" role=\"tab\" data-toggle=\"tab\" data-performance=\"0\" data-code=\"14407414\" data-typename=\"C10000008_CONTAINER\" data-url=\"\/catalog\/weg\/US\/en\/p\/14407414\/getCurve\"\u003e208-230\/460 V 60 Hz 4P \u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#curve-1\" class=\"xtt-ajax-tab\" role=\"tab\" data-toggle=\"tab\" data-performance=\"1\" data-code=\"14407414\" data-typename=\"C10000008_CONTAINER\" data-url=\"\/catalog\/weg\/US\/en\/p\/14407414\/getCurve\"\u003e380 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#curve-2\" class=\"xtt-ajax-tab\" role=\"tab\" data-toggle=\"tab\" data-performance=\"2\" data-code=\"14407414\" data-typename=\"C10000008_CONTAINER\" data-url=\"\/catalog\/weg\/US\/en\/p\/14407414\/getCurve\"\u003e400 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli role=\"presentation\"\u003e \u003ca href=\"#curve-3\" class=\"xtt-ajax-tab\" role=\"tab\" data-toggle=\"tab\" data-performance=\"3\" data-code=\"14407414\" data-typename=\"C10000008_CONTAINER\" data-url=\"\/catalog\/weg\/US\/en\/p\/14407414\/getCurve\"\u003e415 V 50 Hz 4P IE2\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"curve-0\"\u003e\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30\"\u003e\u003cp class=\"alert alert-danger text-center hidden\"\u003eThis document doesn't exist for this product.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"curve-1\"\u003e\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30\"\u003e\u003cp class=\"alert alert-danger text-center hidden\"\u003eThis document doesn't exist for this product.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"curve-2\"\u003e\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30\"\u003e\u003cp class=\"alert alert-danger text-center hidden\"\u003eThis document doesn't exist for this product.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"curve-3\"\u003e\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30\"\u003e\u003cp class=\"alert alert-danger text-center hidden\"\u003eThis document doesn't exist for this product.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane\" id=\"graphic\"\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30 xtt-overflow-x\"\u003e \u003csection id=\"focal\"\u003e\u003cdiv class=\"parent\" style=\"overflow: hidden; position: relative;\"\u003e\u003cdiv class=\"panzoom\" style=\"transform: none; transform-origin: 50% 50%; cursor: move;\"\u003e\u003cdiv id=\"zoomgraphic\" name=\"zoomgraphic\"\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv id=\"zoomButtons\" name=\"zoomButtons\" align=\"right\" style=\"\"\u003e \u003cinput type=\"range\" id=\"zoom-range\" step=\"0.05\" min=\"1\" max=\"6\"\u003e \u003cbutton class=\"btn btn-primary\" id=\"zoom-in\"\u003e\u003ci class=\"icon ion-plus-circled\" style=\"font-size: 18px;\"\u003e\u003c\/i\u003e\u003c\/button\u003e \u003cbutton class=\"btn btn-primary\" id=\"zoom-out\" style=\"margin-left:8px;\"\u003e\u003cspan class=\"icon ion-minus-circled\" style=\"font-size: 18px;\"\u003e\u003c\/span\u003e\u003c\/button\u003e \u003cbutton class=\"btn btn-primary\" id=\"reset\" style=\"margin-left:8px;\"\u003e\u003cspan class=\"icon ion-arrow-expand\" style=\"font-size: 18px;\"\u003e\u003c\/span\u003e\u003c\/button\u003e\n\u003c\/div\u003e \u003c\/section\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-7\"\u003e\n\u003ch4 class=\"p10\"\u003eBearing details\u003c\/h4\u003e\n\u003ctable class=\"xtt-table table table-striped table-hover xtt-table-graphic\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:50%;\"\u003e \u003c\/th\u003e\n\u003cth style=\"width:25%;\" class=\"text-center\"\u003eDrive End\u003c\/th\u003e\n\u003cth style=\"width:25%;\" class=\"text-center\"\u003eNon Drive End\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width:50%\" class=\"wrap\"\u003eBearing type\u003c\/th\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e6311 C3 \u003c\/td\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e6211 C3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:50%\" class=\"wrap\"\u003eSealing\u003c\/th\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003eRetentor com mola \u003c\/td\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003eLip Seal \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:50%\" class=\"wrap\"\u003eLubrication interval\u003c\/th\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e12213 h \u003c\/td\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e13608 h \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:50%\" class=\"wrap\"\u003eLubricant amount\u003c\/th\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e18 g \u003c\/td\u003e\n\u003ctd style=\"width:25%\" class=\"wrap\"\u003e11 g \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:50%\" class=\"wrap\"\u003eGrease Type\u003c\/th\u003e\n\u003ctd style=\"width:50%\" colspan=\"2\" class=\"text-center wrap\"\u003eMobil Polyrex EM \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-md-5\"\u003e\n\u003ch4 class=\"p10\"\u003eFoundation loads\u003c\/h4\u003e\n\u003ctable class=\"xtt-table table table-striped table-hover xtt-table-graphic\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width:50%;\" class=\"text-center\"\u003eMax. traction\u003c\/th\u003e\n\u003cth style=\"width:50%;\" class=\"text-center\"\u003eMax. compression\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"width:50%;\" class=\"wrap\"\u003e1184 lb \u003c\/td\u003e\n\u003ctd style=\"width:50%;\" class=\"wrap\"\u003e1704 lb \u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"plate\"\u003e\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-xs-12 pb30\"\u003e\u003cp class=\"alert alert-danger text-center hidden\"\u003eThis Plate doesn't exist for this product.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e \u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915173527645,"sku":"03018XT3ER286TC","price":4234.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MA57NNHDP6QUF8U0.jpg?v=1766442375"},{"product_id":"03018xt3e286t-weg-30hp-explosion-proof-electric-motor-1800rpm","title":"03018XT3E286T WEG 30HP Explosion Proof Electric Motor, 1800RPM","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"https:\/\/witmermotor.com\/cdn\/shop\/files\/WEGSubpage.css\"\u003e\n\u003cdiv class=\"col-xs-12 col-md-6 product-row-info\"\u003e\n\u003cdiv class=\"xtt-product-description\"\u003eWEG Explosion-proof motor was especially designed to operate in environments with the presence of explosive atmospheres. It has robust construction, a flame retention system with gaps between the parts carefully designed, accurate machining on the terminal box and screws with high mechanical strength. It meets the requirements of explosive atmospheres like Division I\/Zone 1. All ratings meet NEMA Premium Efficiency. Motors are certified for VFD service.\u003c\/div\u003e\n\u003ch5\u003eProduct features\u003c\/h5\u003e\n\u003cdiv class=\"row product-info-specs\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard\u003c\/th\u003e\n\u003ctd\u003e\rNEMA MG-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e\r60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd data-feature-code=\"ytensao_completa_resumo\"\u003e\r208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e\r4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003e\rIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronous speed\u003c\/th\u003e\n\u003ctd\u003e\r1800 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput rating\u003c\/th\u003e\n\u003ctd data-feature-code=\"ypotencia_completa_resumo\"\u003e\r30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e\rFoot-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlange\u003c\/th\u003e\n\u003ctd\u003e\rWithout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003e\rF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal box¹\u003c\/th\u003e\n\u003ctd\u003e\rLeft position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003e\rIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane active\" id=\"datasheet-0\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1775 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.39 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e208-230\/460 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e79.6-72.0\/36.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e629-569\/284 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.9x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e25.0-29.0\/14.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e87.6 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e320 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e30s (cold) 17s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e68.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e516 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r93.6 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r93.6 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-1\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1465 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.33 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e380 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e43.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e278 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e6.4x(Code G)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e14.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e106 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e250 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e516 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r91.7 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.71 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.80 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.84 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-2\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1470 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e2.00 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e41.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e298 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.2x(Code H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e15.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e106 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e280 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e516 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.68 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.78 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.83 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv role=\"tabpanel\" class=\"tab-pane \" id=\"datasheet-3\"\u003e\n\u003cdiv class=\"row xtt-row-no-pad\"\u003e\u003cdiv class=\"clearfix\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e286T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003ctd\u003e30 HP (22 kW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated speed\u003c\/th\u003e\n\u003ctd\u003e1475 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSlip\u003c\/th\u003e\n\u003ctd\u003e1.67 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated voltage\u003c\/th\u003e\n\u003ctd\u003e415 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current\u003c\/th\u003e\n\u003ctd\u003e40.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eL. R. Amperes\u003c\/th\u003e\n\u003ctd\u003e311 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLRC\u003c\/th\u003e\n\u003ctd\u003e7.7x(Code J)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo load current\u003c\/th\u003e\n\u003ctd\u003e16.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated torque\u003c\/th\u003e\n\u003ctd\u003e105 ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor torque\u003c\/th\u003e\n\u003ctd\u003e310 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreakdown torque\u003c\/th\u003e\n\u003ctd\u003e310 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLocked rotor time\u003c\/th\u003e\n\u003ctd\u003e36s (cold) 20s (hot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\u003ctable class=\"table table-striped table-hover xtt-table-50 \"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMoment of inertia (J)\u003c\/th\u003e\n\u003ctd\u003e5.16 sq.ft.lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInsulation Class\u003c\/th\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService factor\u003c\/th\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature rise\u003c\/th\u003e\n\u003ctd\u003e80 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eCont.(S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStarting Method\u003c\/th\u003e\n\u003ctd\u003eDirect On Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e1000 m.a.s.l.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIC411 - TEFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eF-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRotation¹\u003c\/th\u003e\n\u003ctd\u003eBoth (CW and CCW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise level²\u003c\/th\u003e\n\u003ctd\u003e64.0 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight³\u003c\/th\u003e\n\u003ctd\u003e516 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row xtt-engine-notes\"\u003e\u003cdiv class=\"col-xs-12\"\u003e\r(1) Looking the motor from the shaft end.; (2) Measured at 1m and with tolerance of +3dB(A).; (3) Approximate weight, subject to be changed after manufacturing process.; (4) At 100% of full load.\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003eEfficiency\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r92.4 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r93.0 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r92.4 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-xs-12 col-sm-6\"\u003e\n\u003ch4 class=\"pb10\"\u003ePower factor\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"text-center\"\u003e50%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e75%\u003c\/th\u003e\n\u003cth class=\"text-center\"\u003e100%\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-center\"\u003e\r0.66 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.77 \u003c\/td\u003e\n\u003ctd class=\"text-center\"\u003e\r0.82 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"WEG Electric Corporation","offers":[{"title":"Default Title","offer_id":43915173560413,"sku":"03018XT3E286T","price":3823.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/MPJBLCHDP6QUF8U0.jpg?v=1766442375"},{"product_id":"xp0014c-teco-westinghouse-1hp-explosion-proof-electric-motor-1800-rpm","title":"XP0014C Teco-Westinghouse 1HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354701917,"sku":"XP0014C","price":669.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9R9M5U7H635RON50.jpg?v=1766445000"},{"product_id":"xp0016-teco-westinghouse-1hp-explosion-proof-electric-motor-1200-rpm","title":"XP0016 Teco-Westinghouse 1HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 HP\r\n • 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354800221,"sku":"XP0016","price":549.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RSJEKTDJ635RON50.jpg?v=1766445002"},{"product_id":"xp0016c-teco-westinghouse-1hp-explosion-proof-electric-motor-1200-rpm","title":"XP0016C Teco-Westinghouse 1HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354832989,"sku":"XP0016C","price":769.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7BIIPIMJ635RON50.jpg?v=1766445004"},{"product_id":"xp0018-teco-westinghouse-1hp-explosion-proof-electric-motor-900-rpm","title":"XP0018 Teco-Westinghouse 1HP Explosion Proof Electric Motor, 900 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 HP\r\n • 900 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354865757,"sku":"XP0018","price":769.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3U6HSTMJ635RON50.jpg?v=1766445004"},{"product_id":"xp0022-teco-westinghouse-2hp-explosion-proof-electric-motor-3600-rpm","title":"XP0022 Teco-Westinghouse 2HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 2 HP\r\n • 3600 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354898525,"sku":"XP0022","price":559.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/F19BV8NJ635RON50.jpg?v=1766445004"},{"product_id":"xp0022c-teco-westinghouse-2hp-explosion-proof-electric-motor-3600-rpm","title":"XP0022C Teco-Westinghouse 2HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354931293,"sku":"XP0022C","price":779.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/R4B52KNJ635RON50.jpg?v=1766445004"},{"product_id":"xp0024-teco-westinghouse-2hp-explosion-proof-electric-motor-1800-rpm","title":"XP0024 Teco-Westinghouse 2HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 2 HP\r\n • 1800 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354964061,"sku":"XP0024","price":539.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7JBS4VNJ635RON50.jpg?v=1766445005"},{"product_id":"xp0024c-teco-westinghouse-2hp-explosion-proof-electric-motor-1800-rpm","title":"XP0024C Teco-Westinghouse 2HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915354996829,"sku":"XP0024C","price":749.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JMDM7AOJ635RON50.jpg?v=1766445006"},{"product_id":"xp0026-teco-westinghouse-2hp-explosion-proof-electric-motor-1200-rpm","title":"XP0026 Teco-Westinghouse 2HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355029597,"sku":"XP0026","price":689.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V4EDALOJ635RON50.jpg?v=1766445005"},{"product_id":"xp0026c-teco-westinghouse-2hp-explosion-proof-electric-motor-1200-rpm","title":"XP0026C Teco-Westinghouse 2HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355062365,"sku":"XP0026C","price":929.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BJI4FBPJ635RON50.jpg?v=1766445006"},{"product_id":"xp0032-teco-westinghouse-3hp-explosion-proof-electric-motor-3600-rpm","title":"XP0032 Teco-Westinghouse 3HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 3 HP\r\n • 3600 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355095133,"sku":"XP0032","price":639.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JV5NK1QJ635RON50.jpg?v=1766445008"},{"product_id":"xp0034-teco-westinghouse-3hp-explosion-proof-electric-motor-1800-rpm","title":"XP0034 Teco-Westinghouse 3HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 3 HP\r\n • 1800 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355127901,"sku":"XP0034","price":649.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/R6QNVDRJ635RON50.jpg?v=1766445009"},{"product_id":"xp0032cteco-westinghouse-3hp-explosion-proof-electric-motor-3600-rpm","title":"XP0032CTeco-Westinghouse 3HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355160669,"sku":"XP0032C","price":869.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V28HNCQJ635RON50.jpg?v=1766445008"},{"product_id":"xp0034c-teco-westinghouse-3hp-explosion-proof-electric-motor-1800-rpm","title":"XP0034C Teco-Westinghouse 3HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355193437,"sku":"XP0034C","price":869.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7ASH2PRJ635RON50.jpg?v=1766445008"},{"product_id":"xp0036-teco-westinghouse-3hp-explosion-proof-electric-motor-1200-rpm","title":"XP0036 Teco-Westinghouse 3HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355226205,"sku":"XP0036","price":869.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3IIJ54SJ635RON50.jpg?v=1766445009"},{"product_id":"xp0036c-teco-westinghouse-3hp-explosion-proof-electric-motor-1200-rpm","title":"XP0036C Teco-Westinghouse 3HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355258973,"sku":"XP0036C","price":1199.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FLKD8FSJ635RON50.jpg?v=1766445010"},{"product_id":"xp0038-teco-westinghouse-3hp-explosion-proof-electric-motor-900-rpm","title":"XP0038 Teco-Westinghouse 3HP Explosion Proof Electric Motor, 900 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 3 HP\r\n • 900 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355291741,"sku":"XP0038","price":1399.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/R3L4BQSJ635RON50.jpg?v=1766445012"},{"product_id":"xp0052-teco-westinghouse-5hp-explosion-proof-electric-motor-3600-rpm","title":"XP0052 Teco-Westinghouse 5HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355324509,"sku":"XP0052","price":799.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/N180E5TJ635RON50.jpg?v=1766445010"},{"product_id":"xp0052c-teco-westinghouse-5hp-explosion-proof-electric-motor-3600-rpm","title":"XP0052C Teco-Westinghouse 5HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355357277,"sku":"XP0052C","price":999.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JU35JRTJ635RON50.jpg?v=1766445011"},{"product_id":"xp0054c-teco-westinghouse-5hp-explosion-proof-electric-motor-1800-rpm","title":"XP0054C Teco-Westinghouse 5HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355390045,"sku":"XP0054C","price":999.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9GQU434K635RON50.jpg?v=1766445011"},{"product_id":"xp0056-teco-westinghouse-5hp-explosion-proof-electric-motor-1200-rpm","title":"XP0056 Teco-Westinghouse 5HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 5 HP\r\n • 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355422813,"sku":"XP0056","price":1099.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/LJSO7E4K635RON50.jpg?v=1766445013"},{"product_id":"xp0056c-teco-westinghouse-5hp-explosion-proof-electric-motor-1200-rpm","title":"XP0056C Teco-Westinghouse 5HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355455581,"sku":"XP0056C","price":1499.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1NUIAP4K635RON50.jpg?v=1766445012"},{"product_id":"xp0102-teco-westinghouse-10hp-explosion-proof-electric-motor-3600-rpm","title":"XP0102 Teco-Westinghouse 10HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 10 HP\r\n • 3600 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355488349,"sku":"XP0102","price":1099.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PT27GF5K635RON50.jpg?v=1766445014"},{"product_id":"xp0102c-teco-westinghouse-10hp-explosion-proof-electric-motor-3600-rpm","title":"XP0102C Teco-Westinghouse 10HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355521117,"sku":"XP0102C","price":1699.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/L6KVIQ5K635RON50.jpg?v=1766445013"},{"product_id":"xp0104-teco-westinghouse-10hp-explosion-proof-electric-motor-1800-rpm","title":"XP0104 Teco-Westinghouse 10HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 10 HP\r\n • 1800 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355553885,"sku":"XP0104","price":1199.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/1AMPL56K635RON50.jpg?v=1766445015"},{"product_id":"xp0104c-teco-westinghouse-10hp-explosion-proof-electric-motor-1800-rpm","title":"XP0104C Teco-Westinghouse 10HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355586653,"sku":"XP0104C","price":1699.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TSAOOG6K635RON50.jpg?v=1766445015"},{"product_id":"xp0106-teco-westinghouse-10hp-explosion-proof-electric-motor-1200-rpm","title":"XP0106 Teco-Westinghouse 10HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 10HP\r\n • 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355619421,"sku":"XP0106","price":1699.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9AGORR6K635RON50.jpg?v=1766445017"},{"product_id":"xp0106c-teco-westinghouse-10hp-explosion-proof-electric-motor-1200-rpm","title":"XP0106C Teco-Westinghouse 10HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355652189,"sku":"XP0106C","price":2099.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5J1HU67K635RON50.jpg?v=1766445015"},{"product_id":"xp0152-teco-westinghouse-15hp-explosion-proof-electric-motor-3600-rpm","title":"XP0152 Teco-Westinghouse 15HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355684957,"sku":"XP0152","price":1399.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/TRHOHQTM635RON50.jpg?v=1766445016"},{"product_id":"xp0152c-teco-westinghouse-15hp-explosion-proof-electric-motor-3600-rpm","title":"XP0152C Teco-Westinghouse 15HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 15 HP\r\n • 3600 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355717725,"sku":"XP0152C","price":1999.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/9KLLK5UM635RON50.jpg?v=1766445019"},{"product_id":"xp0154c-teco-westinghouse-15hp-explosion-proof-electric-motor-1800-rpm","title":"XP0154C Teco-Westinghouse 15HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 15 HP\r\n • 1800 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355750493,"sku":"XP0154C","price":1999.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5E5O580N635RON50.jpg?v=1766445019"},{"product_id":"xp0156-teco-westinghouse-15hp-explosion-proof-electric-motor-1200-rpm","title":"XP0156 Teco-Westinghouse 15HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355783261,"sku":"XP0156","price":2299.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/12PDAU0N635RON50.jpg?v=1766445018"},{"product_id":"xp0156c-teco-westinghouse-15hp-explosion-proof-electric-motor-1200-rpm","title":"XP0156C Teco-Westinghouse 15HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355816029,"sku":"XP0156C","price":2899.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/DQSAD91N635RON50.jpg?v=1766445018"},{"product_id":"xp0202-teco-westinghouse-20hp-explosion-proof-electric-motor-3600-rpm","title":"XP0202 Teco-Westinghouse 20HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 20HP\r\n • 3600 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355848797,"sku":"XP0202","price":1899.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5B45JV1N635RON50.jpg?v=1766445020"},{"product_id":"xp0202c-teco-westinghouse-20hp-explosion-proof-electric-motor-3600-rpm","title":"XP0202C Teco-Westinghouse 20HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355881565,"sku":"XP0202C","price":2399.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/19N0MA2N635RON50.jpg?v=1766445020"},{"product_id":"xp0204-teco-westinghouse-20hp-explosion-proof-electric-motor-1800-rpm","title":"XP0204 Teco-Westinghouse 20HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 20HP\r\n • 1800 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355914333,"sku":"XP0204","price":1899.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T6ASOL2N635RON50.jpg?v=1766445022"},{"product_id":"xp0204c-teco-westinghouse-20hp-explosion-proof-electric-motor-1800-rpm","title":"XP0204C Teco-Westinghouse 20HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355947101,"sku":"XP0204C","price":2399.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/P4TNR03N635RON50.jpg?v=1766445021"},{"product_id":"xp0206-teco-westinghouse-20hp-explosion-proof-electric-motor-1200-rpm","title":"XP0206 Teco-Westinghouse 20HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915355979869,"sku":"XP0206","price":2699.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/L2GJUB3N635RON50.jpg?v=1766445022"},{"product_id":"xp0206c-teco-westinghouse-20hp-explosion-proof-electric-motor-1200-rpm","title":"XP0206C Teco-Westinghouse 20HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915356012637,"sku":"XP0206C","price":3299.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/16ID1N3N635RON50.jpg?v=1766445021"},{"product_id":"xp0252-teco-westinghouse-25hp-explosion-proof-electric-motor-3600-rpm","title":"XP0252 Teco-Westinghouse 25HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915356045405,"sku":"XP0252","price":2199.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/PA8KB35N635RON50.jpg?v=1766445022"},{"product_id":"xp0252c-teco-westinghouse-25hp-explosion-proof-electric-motor-3600-rpm","title":"XP0252C Teco-Westinghouse 25HP Explosion Proof Electric Motor, 3600 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915356078173,"sku":"XP0252C","price":2799.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/5EAEEE5N635RON50.jpg?v=1766445023"},{"product_id":"xp0254c-teco-westinghouse-25hp-explosion-proof-electric-motor-1800-rpm","title":"XP0254C Teco-Westinghouse 25HP Explosion Proof Electric Motor, 1800 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915356110941,"sku":"XP0254C","price":2899.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HRKGS57N635RON50.jpg?v=1766445024"},{"product_id":"xp0256-teco-westinghouse-25hp-explosion-proof-electric-motor-1200-rpm","title":"XP0256 Teco-Westinghouse 25HP Explosion Proof Electric Motor, 1200 RPM","description":"\r\nAPPLICATIONS:\r\n\r\n • Grain Elevators\r\n • Applications Where Explosive Gases are Present\r\n • Pumps\r\n • Applications Where Explosive Dusts\/ Grains are Present\r\n • Blowers\r\n\r\nFEATURES:\r\n\r\n • 1 - 150 hp\r\n • 1 - 100 hp – Foot Mounted with C-Flange or 1 - 75 hp Round Body with C-Flange\r\n • 3600, 1800, 1200 RPM\r\n • Toally Enclosed Fan Cooled - Explosion Proof (IP55 Rating)\r\n • UL and CSA Listed for Class I, Division I, Group D and Class II, Groups E, F, G; Temp Code T2D\/T3B\r\n • UL File #: E84757\r\n • CSA File #: 64671\r\n • NEMA Premium Efficient Design\r\n • Meets or Exceeds EPAct Efficiency Levels on the Round Body C-Face Design\r\n • Department of Energy Efficiency Certification #CC002A\r\n • 36 Month Warranty from Date of Manufacture\r\n • 60 Hz - 230\/ 460V (Usable on 208V). 150 hp is 460V Only\r\n • 1.15 Service Factor – Continuous\r\n • Class F Insulation with Phenolic Alkyd Resin Varnish\r\n • Standard with Klixon 9700K Temperature Limiting Switch, 1 per Phase\r\n • Class B Temperature Rise\r\n • NEMA Design B Torques\r\n • Oversized Main Conduit Box Rotatable in 90 Degree Increments – Fully Gasketed with NPT Threaded Entrance – F1 Mounted.\r\n • Designed for 40°C Ambient Temperature - Note (1)\r\n • Designed for 3300 ft. Elevation - Note (2)\r\n • Bidirectional Rotation\r\n • Cast Iron Frame, Fan Cover, End Bells, and Main Conduit Box. Capable of Withstanding Explosion Force as Required by UL.\r\n • Stainless Steel Breather Drains with Bronze Filters\r\n • 1045 Carbon Steel Shaft\r\n • Aluminum Die Cast Squirrel Cage Rotor Construction\r\n • Paint System: Phenolic Rust Proof Base Plus Polyurethane Top Coat\r\n • Paint Color: Dark Blue – Munsell 5PB 4.5\/ 2\r\n • Vacuum De-Gassed Regreasable Ball (or Roller) Bearings on Frames 280TS - 445T\/ TS Using Polyrex EM Grease\r\n • Double Shielded Bearings on Frames 140T-280T Pre-Packed with MULTEMP SRL Grease\r\n • Brass Flinger on Both Ends\r\n • Cast Iron Inner and Outer Bearing Caps for Frames 280TS - 445T\/ TS\r\n • Grounding Terminal Inside Main Box\r\n • Stainless Steel Nameplate\r\n • UL Listed for Inverter Duty - Note (3)\r\n • Inverter Duty Magnet Wire Capable of Withstanding Voltage Spikes of Up to 2200 Volts\r\n • Speed Ranges: VT = 3 - 60 H • CT for 140 - 210 frames = 10 - 60 Hz. CT for 250 - 320 frames = 13 - 60 H • CT for 360 - 440 frames = 16 - 60 Hz\r\n • 9 Leads for 5 hp and Below, 12 Leads for 7.5 hp to 125 hp, 6 Leads for 150 hp\r\n • Precautions should be taken to eliminate or reduce shaft currents that may be imposed on the motor by the VFD as stated per NEMA MG1, Part 31.4.4.3.\r\n\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/ProdDesc\/XP.pdf\"\u003eProduct Description\u003c\/a\u003e\r\n\u003ca href=\"https:\/\/buy.tecowestinghouse.com\/EcommerceFiles\/Manuals\/TWMC%20Instruction%20Manual_143%20to%20449%20frame.pdf\"\u003eInstruction Manual\u003c\/a\u003e","brand":"TECO-Westinghouse","offers":[{"title":"Default Title","offer_id":43915356143709,"sku":"XP0256","price":3299.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/T9L7VG7N635RON50.jpg?v=1766445024"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/C156GDDB025RON50.jpg?v=1766430626","url":"https:\/\/witmermotor.com\/collections\/3-phase-explosion-proof.oembed?page=13","provider":"Witmer Motor Service","version":"1.0","type":"link"}