{"title":"Fuji FRENIC-HVAC 200-240V VFDs","description":"","products":[{"product_id":"frn001ar1l-2u-1-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN001AR1L-2U 1 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN001AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1\/4 HP with Single Phase Input\u003cbr\u003e1 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e1.9 Amps with Single Phase Input\u003cbr\u003e5.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e0.7 kVA with Single Phase Input\u003cbr\u003e1.9 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e1.9 Amps with Single Phase Input\u003cbr\u003e5 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e2.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: Ul Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915358437469,"sku":"FRN001AR1L-2U","price":709.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FAQBI76S035RON50.jpg?v=1766445061"},{"product_id":"frn001ar1m-2u-1-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN001AR1M-2U 1 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN001AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1\/4 HP with Single Phase Input\u003cbr\u003e1 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e1.9 Amps with Single Phase Input\u003cbr\u003e5.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1\/4 HP  with Single Phase Input\u003cbr\u003e1 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e0.7 kVA with Single Phase Input\u003cbr\u003e1.9 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e1.9 Amps with Single Phase Input\u003cbr\u003e5.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase\u003cbr\u003e200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase\u003cbr\u003e200 to 240VAC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e2.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase\u003cbr\u003e 200 to 240VAC 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003e+10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003eFrequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97% at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\/\u003cbr\u003eUL 50: UL Type 1 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003cbr\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eFieldbus\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Expansion\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915358535773,"sku":"FRN001AR1M-2U","price":576.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NTGKQA3T035RON50.jpg?v=1766445064"},{"product_id":"frn002ar1l-2u-2-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN002AR1L-2U 2 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN002AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP with Single Phase Input\u003cbr\u003e2 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e3.1 Amps with Single Phase Input\u003cbr\u003e8.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP  with Single Phase Input\u003cbr\u003e2 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e1.2 kVA with Single Phase Input\u003cbr\u003e3.1 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e3.1 Amps with Single Phase Input\u003cbr\u003e8.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e5.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.3 kVA with Single Phase Input\u003cbr\u003e2.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915358699613,"sku":"FRN002AR1L-2U","price":853.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NAM4030U035RON50.jpg?v=1766445068"},{"product_id":"frn002ar1m-2u-2-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN002AR1M-2U 2 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN002AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP with Single Phase Input\u003cbr\u003e2 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e3.1 Amps with Single Phase Input\u003cbr\u003e8.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1\/2 HP  with Single Phase Input\u003cbr\u003e2 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e1.2 kVA with Single Phase Input\u003cbr\u003e3.1 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e3.1 Amps with Single Phase Input\u003cbr\u003e8.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase 200 to 240VAC 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240 V 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e5.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.3 kVA with Single Phase Input\u003cbr\u003e2.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69'\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915358797917,"sku":"FRN002AR1M-2U","price":673.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RCFQ741U035RON50.jpg?v=1766445067"},{"product_id":"frn003ar1l-2u-3-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN003AR1L-2U 3 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN003AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1 HP with Single Phase Input\u003cbr\u003e3 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e4.2 Amps with Single Phase Input\u003cbr\u003e11.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3\/4 HP with Single Phase Input at 208VAC\u003cbr\u003e1 HP with Single Phase Input at 230VAC\u003cbr\u003e3 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e1.6 kVA with Single Phase Input\u003cbr\u003e4.3 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e4.2 Amps with Single Phase Input\u003cbr\u003e 11.0 Amps with Three Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e7.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.8 kVA with Single Phase Input\u003cbr\u003e3.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: Ul Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915358961757,"sku":"FRN003AR1L-2U","price":903.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RO9HSM7U035RON50.jpg?v=1766445071"},{"product_id":"frn003ar1m-2u-3-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN003AR1M-2U 3 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN003AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e1 HP with Single Phase Input\u003cbr\u003e3 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e4.2 Amps with Single Phase Input\u003cbr\u003e11.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3\/4 HP with Single Phase Input @ 208 VAC\u003cbr\u003e1 HP with Single Phase Input @ 230 VAC\u003cbr\u003e3 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e1.6 kVA with Single Phase Input\u003cbr\u003e4.3 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e4.2 Amps with Single Phase Input\u003cbr\u003e11 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e7.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e1.8 kVA with Single Phase Input\u003cbr\u003e3.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21 \u003cbr\u003eUL 50: Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359060061,"sku":"FRN003AR1M-2U","price":709.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FVIE2D8U035RON50.jpg?v=1766445074"},{"product_id":"frn005ar1l-2u-5-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN005AR1L-2U 5 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN005AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e2 HP with Single Phase Input\u003cbr\u003e5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e7.0 Amps with Single Phase Input\u003cbr\u003e18.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\"  (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1.5 HP with Single Phase Input at 208VAC\u003cbr\u003e2 HP with Single Phase Input at 230VAC\u003cbr\u003e5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e2.7 kVA with Single Phase Input\u003cbr\u003e7.1 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e7.0 Amps with Single Phase Input\u003cbr\u003e18.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e12.9 Ampst\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e3.0 kVA with Single Phase Input\u003cbr\u003e5.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359223901,"sku":"FRN005AR1L-2U","price":1004.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/V21QF4AU035RON50.jpg?v=1766445078"},{"product_id":"frn005ar1m-2u-5-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN005AR1M-2U 5 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN005AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e2 HP with Single Phase Input\u003cbr\u003e5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e7.0 Amps with Single Phase Input\u003cbr\u003e18.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e22 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e5.91\" x 18.30\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e1.5 HP  with Single Phase Input at 208VAC\u003cbr\u003e2 HP  with Single Phase Input at 230VAC\u003cbr\u003e5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e2.7 kVA with Single Phase Input\u003cbr\u003e7.1 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e7.0 Amps with Single Phase Input\u003cbr\u003e18.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e12.9 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e3.0 kVA with Single Phase Input\u003cbr\u003e5.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003cbr\u003e5.91\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e465 mm\u003cbr\u003e18.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e17.5 mm\u003cbr\u003e0.69\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e451 mm\u003cbr\u003e17.76\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31“ diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359322205,"sku":"FRN005AR1M-2U","price":813.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3U0GRGBU035RON50.jpg?v=1766445080"},{"product_id":"frn007ar1l-2u-7-5-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN007AR1L-2U 7.5 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e \u003cscript\u003e$(function(){$(\"#accordion\").accordion({heightStyle:\"content\",collapsible:true,active:false});});\u003c\/script\u003e \u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations\u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN007AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input\u003cbr\u003e7.5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e10.5 Amps with Single Phase Input\u003cbr\u003e27.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e2 HP with Single Phase Input at 208VAC\u003cbr\u003e3 HP with Single Phase Input at 230VAC\u003cbr\u003e7.5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e4.1 kVA with Single Phase Input\u003cbr\u003e10 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e10.5 Amps with Single Phase Input\u003cbr\u003e27 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e4.2 kVA with Single Phase Input\u003cbr\u003e7.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90 True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e \u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions\u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2\u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA\u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions\u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions\u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections\u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA\u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars\u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs\u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection\u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block\u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models\u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software\u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card\u003c\/li\u003e\n\u003cli\u003eReal Time Clock\u003c\/li\u003e\n\u003cli\u003eCustomizable Logic\u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control\u003c\/li\u003e\n\u003cli\u003e4-PID Controllers\u003c\/li\u003e\n\u003cli\u003eFire Mode\u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation\u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control\u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms\u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display\u003c\/li\u003e\n\u003cli\u003ePassword\u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In\u003c\/li\u003e\n\u003cli\u003eSingle Phase Input\u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e \u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e \u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e \u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e \u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359486045,"sku":"FRN007AR1L-2U","price":1180.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/J0K498DU035RON50.jpg?v=1766445081"},{"product_id":"frn007ar1m-2u-7-5-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN007AR1M-2U 7.5 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN007AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input\u003cbr\u003e7.5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e10.5 Amps with Single Phase Input\u003cbr\u003e27 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e2 HP  with Single Phase Input at 208VAC\u003cbr\u003e3 HP  with Single Phase Input at 230VAC\u003cbr\u003e7.5 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e4.1 kVA with Single Phase Input\u003cbr\u003e10 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e10.5 Amps with Single Phase Input\u003cbr\u003e27 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e4.2 kVA with Single Phase Input\u003cbr\u003e7.2 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e97 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359584349,"sku":"FRN007AR1M-2U","price":982.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/77T1FUDU035RON50.jpg?v=1766445083"},{"product_id":"frn010ar1l-2u-10-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN010AR1L-2U 10 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN010AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input\u003cbr\u003e10 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e12.4 Amps with Single Phase Input\u003cbr\u003e31.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3 HP  with Single Phase Input\u003cbr\u003e10 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e4.9 kVA with Single Phase Input\u003cbr\u003e12 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e12.4 Amps with Single Phase Input\u003cbr\u003e31.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e24.2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e5.6 kVA with Single Phase Input\u003cbr\u003e10 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359813725,"sku":"FRN010AR1L-2U","price":1429.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NBB672HU035RON50.jpg?v=1766445091"},{"product_id":"frn010ar1m-2u-10-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN010AR1M-2U 10 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN010AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e3 HP with Single Phase Input\u003cbr\u003e10 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e12.4 Amps with Single Phase Input\u003cbr\u003e31.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e3 HP  with Single Phase Input at 208 VAC\u003cbr\u003e10 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e4.9 kVA with Single Phase Input\u003cbr\u003e12 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e12.4 Amps with Single Phase Input\u003cbr\u003e31.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e24.2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e5.6 kVA with Single Phase Input\u003cbr\u003e10 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915359912029,"sku":"FRN010AR1M-2U","price":1191.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/B7M6DOHU035RON50.jpg?v=1766445092"},{"product_id":"frn015ar1l-2u-15-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN015AR1L-2U 15 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN015AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e5 HP with Single Phase Input\u003cbr\u003e15 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps with Single Phase Input\u003cbr\u003e46.2 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e5 HP  with Single Phase Input\u003cbr\u003e15 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e7.1 kVA with Single Phase Input\u003cbr\u003e18.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps with Single Phase Input\u003cbr\u003e46.2 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e36.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e8.3 kVA with Single Phase Input\u003cbr\u003e15 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360108637,"sku":"FRN015AR1L-2U","price":1818.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RL8JETLU035RON50.jpg?v=1766445096"},{"product_id":"frn015ar1m-2u-15-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN015AR1M-2U 15 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN015AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e5 HP with Single Phase Input\u003cbr\u003e15 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps with Single Phase Input\u003cbr\u003e46.2 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e40 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 23.00\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e5 HP  with Single Phase Input\u003cbr\u003e15 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e7.1 kVA with Single Phase Input\u003cbr\u003e18.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e18.0 Amps with Single Phase Input\u003cbr\u003e46.2 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e36.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e8.3 kVA with Single Phase Input\u003cbr\u003e15.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e585 mm\u003cbr\u003e23.03\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e571 mm\u003cbr\u003e22.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360239709,"sku":"FRN015AR1M-2U","price":1501.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/F7KDMUMU035RON50.jpg?v=1766445097"},{"product_id":"frn020ar1l-2u-20-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN020AR1L-2U 20 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN020AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e7.5 HP with Single Phase Input\u003cbr\u003e20 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e23.1 Amps with Single Phase Input\u003cbr\u003e59.4 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e51 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 25.40\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e5 HP with Single Phase Input at 208VAC\u003cbr\u003e7.5 HP with Single Phase Input at 230VAC\u003cbr\u003e20 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e9.2 kVA with Single Phase Input\u003cbr\u003e23.0 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e23.1 Amps with Single Phase Input\u003cbr\u003e59.4 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e48.6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e12 kVA with Single Phase Input\u003cbr\u003e20 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e645 mm\u003cbr\u003e25.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e631 mm\u003cbr\u003e24.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360403549,"sku":"FRN020AR1L-2U","price":2224.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/F0G871PU035RON50.jpg?v=1766445099"},{"product_id":"frn020ar1m-2u-20-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN020AR1M-2U 20 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN020AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e7.5 HP with Single Phase Input\u003cbr\u003e20 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e23.1 Amps with Single Phase Input\u003cbr\u003e59.4 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e51 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e25.40\" x 7.99\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e5 HP  with Single Phase Input at 208VAC\u003cbr\u003e7.5 HP  with Single Phase Input at 230VAC\u003cbr\u003e20 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e9.2 kVA with Single Phase Input\u003cbr\u003e23 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e23.1 Amps with Single Phase Input\u003cbr\u003e59.4 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e48.6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e12 kVA with Single Phase Input\u003cbr\u003e20 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e645 mm\u003cbr\u003e25.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e631 mm\u003cbr\u003e24.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360534621,"sku":"FRN020AR1M-2U","price":1854.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3IR2F2QU035RON50.jpg?v=1766445102"},{"product_id":"frn025ar1l-2u-25-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN025AR1L-2U 25 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN025AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input\u003cbr\u003e25 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e29.1 Amps with Single Phase Input\u003cbr\u003e74.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e51 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e7.99\" x 25.40\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e7.5 HP with Single Phase Input at 208VAC\u003cbr\u003e10 HP with Single Phase Input at 208VAC\u003cbr\u003e25 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e11 kVA with Single Phase Input\u003cbr\u003e29 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e29.1 Amps with Single Phase Input\u003cbr\u003e74.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e60.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e14 kVA with Single Phase Input\u003cbr\u003e24 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e645 mm\u003cbr\u003e25.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e631 mm\u003cbr\u003e24.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360796765,"sku":"FRN025AR1L-2U","price":2786.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/JL5EQERU035RON50.jpg?v=1766445105"},{"product_id":"frn025ar1m-2u-25-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN025AR1M-2U 25 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN025AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input\u003cbr\u003e25 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e29.1 Amps with Single Phase Input\u003cbr\u003e74.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e51 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e25.40\" x 7.99\" x 10.30\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e7.5 HP  with Single Phase Input at 208VAC\u003cbr\u003e10 HP  with Single Phase Input at 230VAC\u003cbr\u003e25 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e11 kVA with Single Phase Input\u003cbr\u003e29 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e29.1 Amps with Single Phase Input\u003cbr\u003e74.8 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e60.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e14 kVA with Single Phase Input\u003cbr\u003e24 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 240VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e203 mm\u003cbr\u003e7.99\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e645 mm\u003cbr\u003e25.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e262 mm\u003cbr\u003e10.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e162 mm\u003cbr\u003e6.38\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003cbr\u003e3.94\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e158 mm\u003cbr\u003e6.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e22.5 mm\u003cbr\u003e0.89\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e631 mm\u003cbr\u003e24.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e7 mm\u003cbr\u003e0.28\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 8 mm diameter\u003cbr\u003e2x 0.31\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915360960605,"sku":"FRN025AR1M-2U","price":2322.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7MP4H7UU035RON50.jpg?v=1766445107"},{"product_id":"frn030ar1l-2u-30-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN030AR1L-2U 30 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN030AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input\u003cbr\u003e30 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e34.3 Amps with Single Phase Input\u003cbr\u003e88.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e110 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.40\" x 29.00\" x 11.20\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input\u003cbr\u003e30 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e13 kVA with Single Phase Input\u003cbr\u003e35 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e34.3 Amps with Single Phase Input\u003cbr\u003e88 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e71.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e17 kVA with Single Phase Input\u003cbr\u003e29 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e265 mm\u003cbr\u003e10.43\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e736 mm\u003cbr\u003e28.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e284 mm\u003cbr\u003e11.18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e184.5 mm\u003cbr\u003e7.26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e99.5 mm\u003cbr\u003e3.92\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e180 mm\u003cbr\u003e7.09\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e716 mm\u003cbr\u003e28.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361189981,"sku":"FRN030AR1L-2U","price":3412.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/N46DUUVU035RON50.jpg?v=1766445109"},{"product_id":"frn030ar1m-2u-30-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN030AR1M-2U 30 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN030AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input\u003cbr\u003e30 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e34.3 Amps with Single Phase Input\u003cbr\u003e88.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e110 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.40\" x 29.00\" x 11.20\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP  with Single Phase Input\u003cbr\u003e30 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e13 kVA with Single Phase Input\u003cbr\u003e35 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e34.3 Amps with Single Phase Input\u003cbr\u003e88.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC, 50\/60Hz (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e71.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e17 kVA with Single Phase Input\u003cbr\u003e29 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e265 mm\u003cbr\u003e10.43\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e736 mm\u003cbr\u003e28.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e284 mm\u003cbr\u003e11.18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e184.5 mm\u003cbr\u003e7.26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e99.5 mm\u003cbr\u003e3.92\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e180 mm\u003cbr\u003e7.09\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e716 mm\u003cbr\u003e28.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361321053,"sku":"FRN030AR1M-2U","price":2844.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/R50C4L0V035RON50.jpg?v=1766445111"},{"product_id":"frn040ar1l-2u-40-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN040AR1L-2U 40 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN040AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e15 HP with Single Phase Input\u003cbr\u003e40 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e44.8 Amps with Single Phase Input\u003cbr\u003e115 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e110 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.40\" x 29.00\" x 11.20\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP with Single Phase Input at 208VAC\u003cbr\u003e15 HP with Single Phase Input at 230VAC\u003cbr\u003e40 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e17 kVA with Single Phase Input\u003cbr\u003e45 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e44.8 Amps with Single Phase Input\u003cbr\u003e115 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e96.9 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e23.0 kVA with Single Phase Input\u003cbr\u003e39 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e265 mm\u003cbr\u003e10.43\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e736 mm\u003cbr\u003e28.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e284 mm\u003cbr\u003e11.18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e184.5 mm\u003cbr\u003e7.26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e99.5 mm\u003cbr\u003e3.92\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e180 mm\u003cbr\u003e7.09\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e716 mm\u003cbr\u003e28.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361484893,"sku":"FRN040AR1L-2U","price":4237.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/RE7Q755V035RON50.jpg?v=1766445113"},{"product_id":"frn040ar1m-2u-40-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN040AR1M-2U 40 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN040AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e15 HP with Single Phase Input\u003cbr\u003e40 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e44.8 Amps with Single Phase Input\u003cbr\u003e115 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e110 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e10.40\" x 29.00\" x 11.20\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e10 HP  with Single Phase Input at 208VAC\u003cbr\u003e15 HP  with Single Phase Input at 230VAC\u003cbr\u003e40 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e17 kVA with Single Phase Input\u003cbr\u003e45 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e44.8 Amps with Single Phase Input\u003cbr\u003e115 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e96.9 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e23 kVA with Single Phase Input\u003cbr\u003e39 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e265 mm\u003cbr\u003e10.43\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e736 mm\u003cbr\u003e28.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e284 mm\u003cbr\u003e11.18\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e184.5 mm\u003cbr\u003e7.26\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e99.5 mm\u003cbr\u003e3.92\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e180 mm\u003cbr\u003e7.09\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e716 mm\u003cbr\u003e28.19\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361615965,"sku":"FRN040AR1M-2U","price":3528.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FAIQDR5V035RON50.jpg?v=1766445114"},{"product_id":"frn050ar1l-2u-50-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN050AR1L-2U 50 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN050AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e20 HP with Single Phase Input\u003cbr\u003e50 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e56.9 Amps with Single Phase Input\u003cbr\u003e146 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e154 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e11.80\" x  34.80\" x 14.50\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e15 HP with Single Phase Input at 208VAC\u003cbr\u003e20 HP with Single Phase Input at 230VAC\u003cbr\u003e50 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e22 kVA with Single Phase Input\u003cbr\u003e58 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e56.9 Amps with Single Phase Input\u003cbr\u003e146 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e121 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e28 kVA with Single Phase Input\u003cbr\u003e49 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e300 mm\u003cbr\u003e11.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e885 mm\u003cbr\u003e34.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e367.9 mm\u003cbr\u003e14.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e240.8 mm\u003cbr\u003e9.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e127.1 mm\u003cbr\u003e5.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e215 mm\u003cbr\u003e8.46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e855 mm\u003cbr\u003e33.66\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e15.5 mm\u003cbr\u003e0.61\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e14.5 mm\u003cbr\u003e0.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 15 mm diameter\u003cbr\u003e2x 0.59\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e15 mm\u003cbr\u003e0.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361845341,"sku":"FRN050AR1L-2U","price":4881.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FDLR098V035RON50.jpg?v=1766445117"},{"product_id":"frn050ar1m-2u-50-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN050AR1M-2U 50 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN050AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e20 HP with Single Phase Input\u003cbr\u003e50 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e56.9 Amps with Single Phase Input\u003cbr\u003e146 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e154 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e11.80\" x 34.80\" x 14.50\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e15 HP with Single Phase Input at 208VAC\u003cbr\u003e20 HP with Single Phase Input at 230VAC\u003cbr\u003e50 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e22 kVA with Single Phase Input\u003cbr\u003e55 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e56.9 Amps with Single Phase Input\u003cbr\u003e146 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e145 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e28 kVA with Single Phase Input\u003cbr\u003e49 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e300 mm\u003cbr\u003e11.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e885 mm\u003cbr\u003e34.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e367.9 mm\u003cbr\u003e14.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e240.8 mm\u003cbr\u003e9.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e127.1 mm\u003cbr\u003e5.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e215 mm\u003cbr\u003e8.46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e855 mm\u003cbr\u003e33.66\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e15.5 mm\u003cbr\u003e0.61\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e14.5 mm\u003cbr\u003e0.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 15 mm diameter\u003cbr\u003e2x 0.59\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e15 mm\u003cbr\u003e0.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915361976413,"sku":"FRN050AR1M-2U","price":4068.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/390S6V8V035RON50.jpg?v=1766445119"},{"product_id":"frn060ar1l-2u-60-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN060AR1L-2U 60 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN060AR1L-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 12\u003cbr\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e25 HP with Single Phase Input\u003cbr\u003e60 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e70.2 Amps with Single Phase Input\u003cbr\u003e180 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e154 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e11.80\" x 34.80\" x 14.50\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e20 HP with Single Phase Input at 208VAC\u003cbr\u003e25 HP with Single Phase Input at 230VAC\u003cbr\u003e60 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e27 kVA with Single Phase Input\u003cbr\u003e71 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e70.2 Amps with Single Phase Input\u003cbr\u003e180 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e145 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e34 kVA with Single Phase Input\u003cbr\u003e58 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP55\u003cbr\u003eUL 50: UL Type 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Type 12: -10 to 40°C (14 to 104°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e300 mm\u003cbr\u003e11.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e885 mm\u003cbr\u003e34.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e367.9 mm\u003cbr\u003e14.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e240.8 mm\u003cbr\u003e9.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e127.1 mm\u003cbr\u003e5.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e215 mm\u003cbr\u003e8.46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e855 mm\u003cbr\u003e33.66\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e15.5 mm\u003cbr\u003e0.61\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e14.5 mm\u003cbr\u003e0.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 15 mm diameter\u003cbr\u003e2x 0.59\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e15 mm\u003cbr\u003e0.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915362205789,"sku":"FRN060AR1L-2U","price":5983.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3GBOM1BV035RON50.jpg?v=1766445121"},{"product_id":"frn060ar1m-2u-60-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN060AR1M-2U 60 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN060AR1M-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Type 1\u003cbr\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e25 HP with Single Phase Input\u003cbr\u003e60 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e70.2 Amps with Single Phase Input\u003cbr\u003e180.0 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e154 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e11.80\" x 34.80\" x 14.50\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e20 HP  with Single Phase Input at 208VAC\u003cbr\u003e25 HP  with Single Phase Input at 230VAC\u003cbr\u003e60 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e27 kVA with Single Phase Input\u003cbr\u003e71 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e70.2 Amps with Single Phase Input\u003cbr\u003e180 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e145 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e34 kVA with Single Phase Input\u003cbr\u003e58 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C2 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eBuilt-in (IEC\/EN 61000-3-2, IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP21\u003cbr\u003eUL 50: UL Type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e70 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open\/Type 1: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e300 mm\u003cbr\u003e11.81\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e885 mm\u003cbr\u003e34.84\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e367.9 mm\u003cbr\u003e14.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e240.8 mm\u003cbr\u003e9.48\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e127.1 mm\u003cbr\u003e5.00\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e215 mm\u003cbr\u003e8.46\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e42.5 mm\u003cbr\u003e1.67\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e855 mm\u003cbr\u003e33.66\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e15.5 mm\u003cbr\u003e0.61\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e14.5 mm\u003cbr\u003e0.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 15 mm diameter\u003cbr\u003e2x 0.59\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e15 mm\u003cbr\u003e0.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915362336861,"sku":"FRN060AR1M-2U","price":4986.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/7H5NSNBV035RON50.jpg?v=1766445123"},{"product_id":"frn075ar1s-2u-75-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN075AR1S-2U 75 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN075AR1S-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIP00\u003cbr\u003eUL Open Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e30 HP with Single Phase Input\u003cbr\u003e75 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e95 Amps with Single Phase Input\u003cbr\u003e215 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e93 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e14.20\" x 29.10\" x 10.90\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e30 HP  with Single Phase Input\u003cbr\u003e75 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e37 kVA with Single Phase Input\u003cbr\u003e85 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e95 Amps with Single Phase Input\u003cbr\u003e215 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e178 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e41 kVA with Single Phase Input\u003cbr\u003e71 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eBuilt-In\u003cbr\u003eEMC standards compliance : Category C3 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard Accessory (Included; Seperately Mounted and Wired)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP00\u003cbr\u003eUL 50: UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open Type: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e355 mm\u003cbr\u003e13.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e740 mm\u003cbr\u003e29.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e270 mm\u003cbr\u003e10.63\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e155 mm\u003cbr\u003e6.10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e275 mm\u003cbr\u003e10.83\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003cbr\u003e1.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e720 mm\u003cbr\u003e28.35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915362730077,"sku":"FRN075AR1S-2U","price":6447.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/NUD0KLIV035RON50.jpg?v=1766445128"},{"product_id":"frn100ar1s-2u-100-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN100AR1S-2U 100 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN100AR1S-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e30 HP with Single Phase Input\u003cbr\u003e100 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e102 Amps with Single Phase Input\u003cbr\u003e283 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e95 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e14.20\" x 29.10\" x 10.90\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e30 HP  with Single Phase Input\u003cbr\u003e100 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e40 kVA with Single Phase Input\u003cbr\u003e112 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e102 Amps with Single Phase Input\u003cbr\u003e283 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e246 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e57 kVA with Single Phase Input\u003cbr\u003e98 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eEMC standards compliance : Category C3 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard Accessory\u003cbr\u003e(IEC\/EN 61000-3-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP00\u003cbr\u003eUL 50: UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e43 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open Type: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e355 mm\u003cbr\u003e13.98\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e740 mm\u003cbr\u003e29.13\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e270 mm\u003cbr\u003e10.63\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e115 mm\u003cbr\u003e4.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e155 mm\u003cbr\u003e6.10\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e275 mm\u003cbr\u003e10.83\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003cbr\u003e1.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e720 mm\u003cbr\u003e28.35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003cbr\u003e0.47\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003cbr\u003e0.31\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 10 mm diameter\u003cbr\u003e2x 0.39\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e10 mm\u003cbr\u003e0.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915363057757,"sku":"FRN100AR1S-2U","price":7812.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/BUA1PARV035RON50.jpg?v=1766445131"},{"product_id":"frn125ar1s-2u-125-hp-fuji-hvac-variable-frequency-drive-vfd","title":"FRN125AR1S-2U 125 HP Fuji HVAC Variable Frequency Drive (VFD)","description":"\u003chtmlonly\u003e\u003clink rel=\"stylesheet\" href=\"\/Static\/css\/VendorBranding\/accordion.css\"\u003e\n\u003cscript\u003e$( function() {$( \"#accordion\" ).accordion({heightStyle:\"content\", collapsible: true, active:false});} );\u003c\/script\u003e\u003cdiv id=\"accordion\"\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cp\u003eFuji Electric’s FRENIC-HVAC Drive has been designed with features and functions specifically targeted to HVAC Motor Control Applications. The result is a low voltage drive that that provides the optimal environmental control to maintain comfortable conditions in commercial spaces and industrial facilities while generating efficiency beyond typical motor starters.\u003c\/p\u003e\n\u003cp\u003eDeveloped with unyielding standards of quality and flexibility to meet the demands of various applications within HVAC motor control requirements the FRENIC-HVAC Drive is the right choice for a full range of HVAC installations \u003c\/p\u003e\n\u003cp\u003eFuji Electric’s robust design standards and Ease of Commissioning make the FRENIC-HVAC Drive a Service Provider’s favorite choice for quick and sustainable results. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel Number\u003c\/th\u003e\n\u003ctd\u003eFRN125AR1S-2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eUL\/NEMA Open Type\u003cbr\u003eIP00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e208\/230VAC 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP Rating\u003c\/th\u003e\n\u003ctd\u003e30 HP with Single Phase Input\u003cbr\u003e125 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Current\u003c\/th\u003e\n\u003ctd\u003e131 Amps with Single Phase Input\u003cbr\u003e346 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e137 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e21.10\" x 29.50\" x 11.50\" (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e3 Years from date of shipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Applied Motor (Rated Output)\u003c\/th\u003e\n\u003ctd\u003e40 HP with Single Phase Input at 208VAC\u003cbr\u003e50 HP with Single Phase Input at 230VAC\u003cbr\u003e125 HP with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Capacity\u003c\/th\u003e\n\u003ctd\u003e52 kVA with Single Phase Input\u003cbr\u003e137 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Output Current\u003c\/th\u003e\n\u003ctd\u003e131 Amps with Single Phase Input\u003cbr\u003e346 Amps with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd\u003e120Hz Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Stability\u003c\/th\u003e\n\u003ctd\u003eAnalog Setting: ±0.2% of Maximum Frequency\u003cbr\u003eDigital Setting: ±0.01% of Maximum Frequency (By Keypad) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Voltage\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 230VAC (with AVR Function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput Overload Capability\u003c\/th\u003e\n\u003ctd\u003e110% for 1 Minute\u003cbr\u003e(Overload capability interval : IEC 61800-2 compliant) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Frequency\u003c\/th\u003e\n\u003ctd\u003e50, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMain Power Supply Input\u003c\/th\u003e\n\u003ctd\u003eThree Phase, 200 to 220VAC, 50Hz\u003cbr\u003eThree Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Input Current\u003c\/th\u003e\n\u003ctd\u003e291 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired Input Power Supply Capacity\u003c\/th\u003e\n\u003ctd\u003e67 kVA with Single Phase Input\u003cbr\u003e116 kVA with 3-Phase Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Control Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 230VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Main Power Supply\u003c\/th\u003e\n\u003ctd\u003eSingle Phase, 200 to 220VAC, 50Hz\u003cbr\u003eSingle Phase, 200 to 230VAC, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \u0026amp; Frequency Variations\u003c\/th\u003e\n\u003ctd\u003eVoltage: +10 to -15%\u003cbr\u003eInterphase Voltage Unbalance: 2% or less\u003cbr\u003e Frequency: +5 to -5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking Torque\u003c\/th\u003e\n\u003ctd\u003e10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Injection Braking\u003c\/th\u003e\n\u003ctd\u003eStarting frequency:0.0 to 60.0Hz\u003cbr\u003eBraking time:0.0 to 30.0s \u003cbr\u003eBraking level:0 to 60% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEMC Filter\u003c\/th\u003e\n\u003ctd\u003eEMC standards compliance : Category C3 (emission) \/ 2nd Env. (Immunity) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Reactor\u003c\/th\u003e\n\u003ctd\u003eStandard Accessory\u003cbr\u003e(IEC\/EN 61000-3-12) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Factor (at Rated Load)\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;0.98 Displacement P.F. (cosf)\u003cbr\u003e\u0026gt;=0.90  True Power Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003e98 % at Rated Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60529: IP00\u003cbr\u003eUL 50: UL Open Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eFan Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\/Mass\u003c\/th\u003e\n\u003ctd\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd\u003eNEMA\/UL Open Type: -10 to 50°C (14 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temperature\u003c\/th\u003e\n\u003ctd\u003e-25 to 70°C (-13 to 158°F) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5 to 95% RH (Without Condensation) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstallation Location\u003c\/th\u003e\n\u003ctd\u003eIEC60664-1 Pollution Degree 2\u003cbr\u003e(Free from Corrosive Gases, Flammable Gases, Oil Mist, Dust and Direct Sunlight)\u003cbr\u003eIndoor Use Only \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAltitude\u003c\/th\u003e\n\u003ctd\u003e0 to 3,300ft (1,000m)\u003cbr\u003e3,300ft (1,000m) to 9,900ft (3,000m) with Derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cb\u003eControl Inputs \u0026amp; Outputs\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e9 Digital Inputs: X1 – X7, FWD, \u0026amp; REV Programmable\u003cbr\u003e67 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Safety Input (dedicated): EN1, EN2 \u003c\/li\u003e\n\u003cli\u003e3 Analog Inputs: (2) 0 to +10Vdc \u0026amp; (1) 4 to 20mA \u003c\/li\u003e\n\u003cli\u003e6 Digital Outputs: (2) Relays (1 Form C \u0026amp; 1 Form A) \u0026amp; (4) Transistor\u003cbr\u003e77 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 Analog Output: Selectable Type: 0 to 10Vdc or 4 to 20mA\u003cbr\u003e43 Selectable Functions \u003c\/li\u003e\n\u003cli\u003e2 RS-485 Connections: RJ45 Keypad Port \u0026amp; RS485 Control Terminal Block Connections \u003c\/li\u003e\n\u003cli\u003e24Vdc Output Terminal: Rated 200mA \u003c\/li\u003e\n\u003cli\u003eKeypad with large LCD Display Indicating HVAC System Operation and Associated Unit Conversion Displayed \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eRobust Design\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eNickel (Ni) \u0026amp; Tin (Sn) Plated Bus Bars \u003c\/li\u003e\n\u003cli\u003eConformal Coated PCBs \u003c\/li\u003e\n\u003cli\u003eCooling Fan Board Coating + Anti-Rust Protection \u003c\/li\u003e\n\u003cli\u003e10 Year Design Life of Cooling Fan and Capacitor with Maintenance Alarm Output Signal \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eFlexibility \u0026amp; Functionality\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eRemovable Control Terminal Block \u003c\/li\u003e\n\u003cli\u003eCE Filter Built-In for All Models \u003c\/li\u003e\n\u003cli\u003eDCR for All Models\u003c\/li\u003e\n\u003cli\u003ePC Programming \u0026amp; Troubleshooting Software \u003c\/li\u003e\n\u003cli\u003eUSB Port on Control Card \u003c\/li\u003e\n\u003cli\u003eReal Time Clock \u003c\/li\u003e\n\u003cli\u003eCustomizable Logic \u003c\/li\u003e\n\u003cli\u003eAutomatic Energy Savings Control \u003c\/li\u003e\n\u003cli\u003e4-PID Controllers \u003c\/li\u003e\n\u003cli\u003eFire Mode \u003c\/li\u003e\n\u003cli\u003eCatch a Spinning Motor\u003c\/li\u003e\n\u003cli\u003eFilter Clogging Prevention\/Reversing Operation \u003c\/li\u003e\n\u003cli\u003eWet-Bulb Temperature Presumption Control \u003c\/li\u003e\n\u003cli\u003eSelectable “Light” Alarms \u003c\/li\u003e\n\u003cli\u003ePID Units of Measurement Display \u003c\/li\u003e\n\u003cli\u003ePassword \u003c\/li\u003e\n\u003cli\u003e3 Option Card Ports Built-In \u003c\/li\u003e\n\u003cli\u003eSingle Phase Input \u003c\/li\u003e\n\u003cli\u003eBACnet MS\/TP, Metasys N2, Modbus RTUD Embedded \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\u003cb\u003eSafety \u0026amp; Standards\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003eSafety Input\u003c\/li\u003e\n\u003cli\u003eUL 508C, CE\u003c\/li\u003e\n\u003cli\u003eUL Plenum Rating\u003c\/li\u003e\n\u003cli\u003eRoHS \u003c\/li\u003e\n\u003cli\u003eSEMI F47-0706 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eCodes and Standards\u003c\/h3\u003e\n\u003cdiv\u003e\u003cul\u003e\n\u003cli\u003eUL508C\u003c\/li\u003e\n\u003cli\u003eC22.2 No.14,\u003c\/li\u003e\n\u003cli\u003eEN61800-5-1:2007\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003ch3\u003eOptions\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cb\u003eCommunication Options\u003c\/b\u003e\u003cli\u003eEthernet\u003c\/li\u003e\n\u003cli\u003eCC-Link\u003c\/li\u003e\n\u003cli\u003eLONWORKS\u003c\/li\u003e\n\u003cli\u003eDeviceNet\u003c\/li\u003e\n\u003cli\u003eProfibus DP\u003c\/li\u003e\n\u003cli\u003eCANopen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cbr\u003e\u003cb\u003eI\/O Options\u003c\/b\u003e\u003cli\u003eKeypad with USB Port\u003c\/li\u003e\n\u003cli\u003eRelay Output\u003c\/li\u003e\n\u003cli\u003eAnalog Inputs and Outputs\u003c\/li\u003e\n\u003cli\u003eTemperature Sensor Input \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003cdiv\u003e\u003cdiv class=\"productspecifications\"\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eW\u003c\/th\u003e\n\u003ctd\u003e530 mm\u003cbr\u003e20.87\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH\u003c\/th\u003e\n\u003ctd\u003e750 mm\u003cbr\u003e29.53\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003ctd\u003e285 mm\u003cbr\u003e11.22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD1\u003c\/th\u003e\n\u003ctd\u003e145 mm\u003cbr\u003e5.71\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eD2\u003c\/th\u003e\n\u003ctd\u003e140 mm\u003cbr\u003e5.51\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW1\u003c\/th\u003e\n\u003ctd\u003e430 mm\u003cbr\u003e16.93\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eW2\u003c\/th\u003e\n\u003ctd\u003e50 mm\u003cbr\u003e1.97\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH1\u003c\/th\u003e\n\u003ctd\u003e720 mm\u003cbr\u003e28.35\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH2\u003c\/th\u003e\n\u003ctd\u003e15.5 mm\u003cbr\u003e0.61\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eH3\u003c\/th\u003e\n\u003ctd\u003e14.5 mm\u003cbr\u003e0.57\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eM\u003c\/th\u003e\n\u003ctd\u003e2x 15 mm diameter\u003cbr\u003e2x 0.59\" diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eN\u003c\/th\u003e\n\u003ctd\u003e15 mm\u003cbr\u003e0.59\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003ch3\u003eLinks\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Quick_Start_Guide-FECA-HVACQRG.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Quick Reference Guide\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-Datasheet-FEA-ACDR-DS-106.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Datasheet\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENICHVACSpecifications_0.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_General_Spec_FECA-TE-134.pdf\" target=\"_blank\"\u003eFRENIC-HVAC General Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/HVAC_EngSpec_FECA-TE-133.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Engineering Specifications\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-IM-INR-SI47-1610f-E.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Instruction Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC-HVAC-UM-24A7-E-0069d.pdf\" target=\"_blank\"\u003eFRENIC-HVAC User's Manual\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/FRENIC_HVAC_Brochure_FECA-BR104a.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Brochure\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/24A1-E-0068c.pdf\" target=\"_blank\"\u003eFRENIC-HVAC Catalog\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/htmlonly\u003e","brand":"Fuji Electric Corp. of America","offers":[{"title":"Default Title","offer_id":43915363352669,"sku":"FRN125AR1S-2U","price":9439.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/files\/3E8V9DTV035RON50.jpg?v=1766445136"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/4005\/8973\/collections\/6GDR8E9U6SS1ANB0.jpg?v=1766430907","url":"https:\/\/witmermotor.com\/collections\/200-240v.oembed?page=2","provider":"Witmer Motor Service","version":"1.0","type":"link"}